Literature DB >> 22576866

Evaluating miniscrew position using orthopantomograms compared to cone-beam computed tomography.

Ruth Bennemann1, Martin Baxmann, Ludger Keilig, Susanne Reimann, Bert Braumann, Christoph Bourauel.   

Abstract

OBJECTIVE: Our objective was to compare the diagnostic capabilities of the orthopantomogram (OPT) as a standard dental diagnostic procedure with those of cone-beam computed tomography (CBCT). We examined the extent to which the OPT allowed miniscrew position to be estimated, and whether probands from different backgrounds in dental medicine arrived at the same conclusions regarding the screw position using the same radiological images (OPTs).
MATERIALS AND METHODS: First, a tomas® pin 8 mm in length and 1.2 mm in diameter (Dentaurum, Ispringen, Germany) was inserted in all four quadrants of nine macerated skulls. These nine skulls were then imaged by OPT and CBCT. The OPTs were presented to probands whose task it was to estimate the miniscrew position in relation to the neighboring structures in an evaluation form. The probands surveyed came from three different backgrounds in dental medicine: orthodontists, oral and maxillofacial surgeons, and dental students. Comparison with the CBCT was made by measuring the CBCTs using the GALILEOS Viewer (Sirona, Bensheim, Germany), and these results were compared with those in the evaluation forms.
RESULTS: In this study, it could be shown that none of the three proband groups estimated the screw's position in the OPT significantly better or worse in comparison to the CBCT. The probands' assessments of the miniscrew's proximity to the dental root differed, and in many cases did not correspond exactly with the CBCT measurement. The majority of probands estimated the likelihood of an opposing corticalis perforation as small, as confirmed in the CBCTs. The proximity of the miniscrew to the maxillary sinus or inferior alveolar nerve was similarly assessed by most of the probands, as also determined in the CBCT. However, the OPT assessments of some probands of the proximity to the maxillary sinus and/or inferior alveolar nerve differed from the proximity measured in the CBCT.
CONCLUSION: Overall our study demonstrates that the OPTs enabled a rough evaluation of the miniscrew position in relation to the surrounding structures. However, the probands' assessments were imprecise. Major deviations appeared in the determination of the proximity of the screw to the dental root. For this reason, if there is any doubt, patients should take advantage of three-dimensional (3D) diagnostics, preferably before any surgical intervention. This is true, for example, if it is unclear whether a root will be or has been perforated, or indeed whether there is sufficient transverse bone tissue.

Entities:  

Mesh:

Year:  2012        PMID: 22576866     DOI: 10.1007/s00056-012-0079-y

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  18 in total

1.  Anatomic variability in alveolar sites for skeletal anchorage.

Authors:  Fernando Lima Martinelli; Ronir Raggio Luiz; Marcelo Faria; Lincoln Issamu Nojima
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-09       Impact factor: 2.650

2.  Drift characteristics of miniscrews and molars for anchorage under orthodontic force: 3-dimensional computed tomography registration evaluation.

Authors:  Hong Liu; Tao Lv; Na-Na Wang; Fang Zhao; Ke-Tao Wang; Dong-Xu Liu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-01       Impact factor: 2.650

Review 3.  Indications for digital volume tomography in orthodontics.

Authors:  Eva Müssig; René Wörtche; Christopher J Lux
Journal:  J Orofac Orthop       Date:  2005-05       Impact factor: 1.938

4.  Parameters affecting primary stability of orthodontic mini-implants.

Authors:  Benedict Wilmes; Carsten Rademacher; Gudrun Olthoff; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2006-05       Impact factor: 1.938

5.  Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Tohru Yoshida; Akiko Ono; Noriyoshi Shimizu
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Sep-Oct       Impact factor: 2.804

6.  Root proximity is a major factor for screw failure in orthodontic anchorage.

Authors:  Shingo Kuroda; Kazuyo Yamada; Toru Deguchi; Takashi Hashimoto; Hee-Moon Kyung; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

7.  A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants.

Authors:  M S Reddy; T Mayfield-Donahoo; F J Vanderven; M K Jeffcoat
Journal:  Clin Oral Implants Res       Date:  1994-12       Impact factor: 5.977

8.  Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement.

Authors:  Hussein H Ammar; Peter Ngan; Richard J Crout; Victor H Mucino; Osama M Mukdadi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-01       Impact factor: 2.650

9.  Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement.

Authors:  Ju-Eun Lim; Won Hee Lim; Yoon Sic Chun
Journal:  Clin Anat       Date:  2008-09       Impact factor: 2.414

10.  Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography.

Authors:  Mona Mohamed Salah Fayed; Pawel Pazera; Christos Katsaros
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

View more
  5 in total

1.  Study of edge detection task in dental panoramic radiographs.

Authors:  L Gráfová; M Kasparová; S Kakawand; A Procházka; T Dostálová
Journal:  Dentomaxillofac Radiol       Date:  2013-05-02       Impact factor: 2.419

Review 2.  Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review.

Authors:  Gabriela-Franco-da Rosa Caetano; Mariana-Quirino-Silveira Soares; Luciana-Butini Oliveira; José-Luiz-Cintra Junqueira; Monikelly-do Carmo-Chagas Nascimento
Journal:  J Clin Exp Dent       Date:  2022-08-01

3.  Evaluation of factors influencing the success rate of orthodontic microimplants using panoramic radiographs.

Authors:  Jae Hyun Park; Jong-Moon Chae; R Curtis Bay; Mi-Jung Kim; Keun-Young Lee; Na-Young Chang
Journal:  Korean J Orthod       Date:  2017-11-19       Impact factor: 1.372

4.  Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

Authors:  Shoaleh Shahidi; Barbad Zamiri; Masoud Abolvardi; Marzieh Akhlaghian; Maryam Paknahad
Journal:  J Dent (Shiraz)       Date:  2018-06

5.  Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography.

Authors:  Mona A Abbassy; Hanady M Sabban; Ali H Hassan; Khalid H Zawawi
Journal:  Saudi Med J       Date:  2015-11       Impact factor: 1.484

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.