Literature DB >> 17936763

Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE.

Lu Kang1, Alison L Galvin, Thomas D Brown, Zhongmin Jin, John Fisher.   

Abstract

A computational model has been developed to quantify the degree of cross-shear of a polyethylene pin articulating against a metallic plate, based on the direct simulation of a multidirectional pin-on-plate wear machine. The principal molecular orientation (PMO) was determined for each polymer site. The frictional work in the direction perpendicular to the PMO was assumed to produce the greatest orientation softening [Wang et al., 1997. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene. Wear 203-204, 230-241]. The cross-shear ratio (CS) was defined as the frictional work perpendicular to the PMO direction, divided by the total frictional work. Cross-shear on the pin contact surface was location specific, and of continuously changing magnitude because the direction of frictional force continuously changed due to pin rotation. The polymer pin motion was varied from a purely linear track (CS=0) up to a maximum rotation of +/-55 degrees (CS=0.254). The relationship between wear factors (K) measured experimentally and theoretically predicted CS was defined using logarithmic functions for both conventional and highly cross-linked ultra-high molecular weight polyethylene (UHMWPE). Cross-shear increased the apparent wear factor for both polyethylenes by more than fivefold compared to unidirectional wear.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17936763      PMCID: PMC2239346          DOI: 10.1016/j.jbiomech.2007.09.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  14 in total

1.  Type of motion and lubricant in wear simulation of polyethylene acetabular cup.

Authors:  V Saikko; T Ahlroos
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

Review 2.  Biological reactions to wear debris in total joint replacement.

Authors:  E Ingham; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

3.  A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

Authors:  P S Barbour; M H Stone; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

4.  Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators.

Authors:  Vesa Saikko; Olof Calonius
Journal:  J Biomech       Date:  2002-04       Impact factor: 2.712

5.  Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis.

Authors:  Vesa Saikko; Olof Calonius; Jaakko Keränen
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-05-15       Impact factor: 3.368

6.  Molecular orientation of ultrahigh molecular weight polyethylene induced by various sliding motions.

Authors:  Sharadha Sambasivan; Daniel A Fischer; Ming C Shen; Stephen M Hsu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-08-15       Impact factor: 3.368

7.  Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding.

Authors:  V Saikko
Journal:  Proc Inst Mech Eng H       Date:  2006-10       Impact factor: 1.617

8.  A multidirectional motion pin-on-disk wear test method for prosthetic joint materials.

Authors:  V Saikko
Journal:  J Biomed Mater Res       Date:  1998-07

9.  A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty.

Authors:  T A Maxian; T D Brown; D R Pedersen; J J Callaghan
Journal:  J Biomech       Date:  1996-05       Impact factor: 2.712

10.  The importance of multidirectional motion on the wear of polyethylene.

Authors:  C R Bragdon; D O O'Connor; J D Lowenstein; M Jasty; W D Syniuta
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

View more
  21 in total

1.  Preferential superior surface motion in wear simulations of the Charité total disc replacement.

Authors:  Curtis M Goreham-Voss; Rachel Vicars; Richard M Hall; Thomas D Brown
Journal:  Eur Spine J       Date:  2010-06-26       Impact factor: 3.134

Review 2.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

3.  2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total knees.

Authors:  John Fisher; Louise M Jennings; Alison L Galvin; Zhongmin M Jin; Martin H Stone; Eileen Ingham
Journal:  Clin Orthop Relat Res       Date:  2009-08-11       Impact factor: 4.176

4.  Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

Authors:  C Quental; J Folgado; P R Fernandes; J Monteiro
Journal:  Med Biol Eng Comput       Date:  2014-11-02       Impact factor: 2.602

5.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

6.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

7.  Cross-Shear in Metal-on-Polyethylene Articulation of Orthopaedic Implants and its Relationship to Wear.

Authors:  T Schwenke; M A Wimmer
Journal:  Wear       Date:  2013-04       Impact factor: 3.892

8.  How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

Authors:  Robin Pourzal; Christopher B Knowlton; Deborah J Hall; Michel P Laurent; Robert M Urban; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2016-02-18       Impact factor: 4.176

9.  Midterm osteolysis-induced aseptic failure of the M6-C™ cervical total disc replacement secondary to polyethylene wear debris.

Authors:  Matthew Scott-Young; Evelyne Rathbone; Lauren Grierson
Journal:  Eur Spine J       Date:  2022-01-12       Impact factor: 2.721

10.  Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Janet Basson; Jens Schwiesau; Bernhard Fritz; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2008-12-03       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.