Preferential superior surface motion in wear simulations of the Charité total disc replacement.

Curtis M Goreham-Voss1, Rachel Vicars, Richard M Hall, Thomas D Brown.   

Abstract

Laboratory wear simulations of the dual-bearing surface Charité total disc replacement (TDR) are complicated by the non-specificity of the device's center of rotation (CoR). Previous studies have suggested that articulation of the Charité preferentially occurs at the superior-bearing surface, although it is not clear how sensitive this phenomenon is to lubrication conditions or CoR location. In this study, a computational wear model is used to study the articulation kinematics and wear of the Charité TDR. Implant wear was found to be insensitive to the CoR location, although seemingly non-physiologic endplate motion can result. Articulation and wear were biased significantly to the superior-bearing surface, even in the presence of significant perturbations of loading and friction. The computational wear model provides novel insight into the mechanics and wear of the Charité TDR, allowing for better interpretation of in vivo results, and giving useful insight for designing future laboratory physical tests.

Entities:  

Mesh:

Year:  2010        PMID: 20582556      PMCID: PMC3377802          DOI: 10.1007/s00586-010-1490-y

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  21 in total

1.  Type of motion and lubricant in wear simulation of polyethylene acetabular cup.

Authors:  V Saikko; T Ahlroos
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

2.  Mobility and contact mechanics of a rotating platform total knee replacement.

Authors:  J K Otto; J J Callaghan; T D Brown
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

3.  Response of Charité total disc replacement under physiologic loads: prosthesis component motion patterns.

Authors:  Patrick O'Leary; Michael Nicolakis; Mark A Lorenz; Leonard I Voronov; Michael R Zindrick; Alexander Ghanayem; Robert M Havey; Gerard Carandang; Mark Sartori; Ioannis N Gaitanis; Stanley Fronczak; Avinash G Patwardhan
Journal:  Spine J       Date:  2005 Nov-Dec       Impact factor: 4.166

4.  Revision of a Charité artificial disc 9.5 years in vivo to a new Charité artificial disc: case report and explant analysis.

Authors:  Thierry David
Journal:  Eur Spine J       Date:  2005-01-26       Impact factor: 3.134

5.  In vitro wear assessment of the Charité Artificial Disc according to ASTM recommendations.

Authors:  Hassan A Serhan; Andrew P Dooris; Matthew L Parsons; Paul J Ares; Stefan M Gabriel
Journal:  Spine (Phila Pa 1976)       Date:  2006-08-01       Impact factor: 3.468

6.  Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty.

Authors:  T A Maxian; T D Brown; D R Pedersen; J J Callaghan
Journal:  J Orthop Res       Date:  1996-07       Impact factor: 3.494

7.  A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty.

Authors:  T A Maxian; T D Brown; D R Pedersen; J J Callaghan
Journal:  J Biomech       Date:  1996-05       Impact factor: 2.712

8.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

9.  Analysis of a retrieved polyethylene total disc replacement component.

Authors:  Steven M Kurtz; John Peloza; Ryan Siskey; Marta L Villarraga
Journal:  Spine J       Date:  2005 May-Jun       Impact factor: 4.166

10.  Spinal implant debris-induced osteolysis.

Authors:  Nadim J Hallab; Brian W Cunningham; Joshua J Jacobs
Journal:  Spine (Phila Pa 1976)       Date:  2003-10-15       Impact factor: 3.468

View more
  4 in total

1.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

2.  The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement.

Authors:  Rachel Vicars; Polina Prokopovich; Thomas D Brown; Joanne L Tipper; Eileen Ingham; John Fisher; Richard M Hall
Journal:  Spine (Phila Pa 1976)       Date:  2012-04-20       Impact factor: 3.468

3.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

4.  ISASS Policy Statement - Lumbar Artificial Disc.

Authors:  Jack Zigler; Rolando Garcia
Journal:  Int J Spine Surg       Date:  2015-03-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.