Literature DB >> 8885652

The importance of multidirectional motion on the wear of polyethylene.

C R Bragdon1, D O O'Connor, J D Lowenstein, M Jasty, W D Syniuta.   

Abstract

The development of a new hip simulator for the study of bearing materials used in total hip replacements has led to several findings which add important new information to the understanding of wear process of ultra-high molecular weight polyethylene, the most commonly used bearing material today for total joint replacements. Using this hip simulator which is capable of applying the physiological motion pathways occurring during gait to total hip components which are held in the correct anatomical position under the complex loading conditions of the hip in gait, the authors have shown that physiological motion pathways produce very different wear rates and morphology of the wear surface than unidirectional reciprocating pathways. Scanning electron microscopy studies show striking differences in the morphology of the wear surfaces of the polyethylene depending upon the relative motions of the components. Wear rates, surface morphology and particle debris generation consistent with clinical and retrieved studies are achieved when physiological conditions are simulated.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8885652     DOI: 10.1243/PIME_PROC_1996_210_408_02

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  17 in total

1.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  The use of self-mating PEEK as an alternative bearing material for cervical disc arthroplasty: a comparison of different simulator inputs and tribological environments.

Authors:  Tim Brown; Qi-Bin Bao
Journal:  Eur Spine J       Date:  2012-03-14       Impact factor: 3.134

4.  Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE.

Authors:  Lu Kang; Alison L Galvin; Thomas D Brown; Zhongmin Jin; John Fisher
Journal:  J Biomech       Date:  2007-10-22       Impact factor: 2.712

5.  Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Nucl Instrum Methods Phys Res B       Date:  2007-12       Impact factor: 1.377

6.  Synthesis and Mechanical Wear Studies of Ultra Smooth Nanostructured Diamond (USND) Coatings Deposited by Microwave Plasma Chemical Vapor Deposition with He/H(2)/CH(4)/N(2) Mixtures.

Authors:  S Chowdhury; J Borham; S A Catledge; A W Eberhardt; P S Johnson; Y K Vohra
Journal:  Diam Relat Mater       Date:  2008       Impact factor: 3.315

7.  Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study.

Authors:  Zoran Bascarevic; Zoran Vukasinovic; Nemanja Slavkovic; Borislav Dulic; Goran Trajkovic; Violeta Bascarevic; Sladjan Timotijevic
Journal:  Int Orthop       Date:  2009-11-01       Impact factor: 3.075

8.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

9.  Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Janet Basson; Jens Schwiesau; Bernhard Fritz; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2008-12-03       Impact factor: 3.134

10.  Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene.

Authors:  Michael R Hill; Shane A Catledge; Valeriy Konovalov; William C Clem; Shafiul A Chowdhury; Brandon S Etheridge; Andrei Stanishevsky; Jack E Lemons; Yogesh K Vohra; Alan W Eberhardt
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-04       Impact factor: 3.368

View more