Cross-Shear in Metal-on-Polyethylene Articulation of Orthopaedic Implants and its Relationship to Wear.

T Schwenke1, M A Wimmer.   

Abstract

Wear of polyethylene (UHMWPE) is dependent on cross-shear. The aim of the present study was: 1) to develop a theoretical description of cross-shear, 2) to experimentally determine the relationship between cross-shear motion and UHMWPE wear using a wheel-on-flat apparatus, and 3) to calculate the work it takes to remove a unit volume of wear for the use in advanced computational models of wear. The theoretical description of cross-shear has been based on the previously reported finding that cross-shear is maximal when movement occurs perpendicular to fibril orientation. Here, cross-shear is described with a double-sinusoidal function that uses the angle between fibril orientation and velocity vector as input, and maximum cross-shear occurs at 90° and 270°. In the experimental part of the study, friction and wear of polyethylene were plotted against increasing sliding velocity vector angles, i.e. increasing cross-shear. It was found that wear intensified with increasing cross-shear, and wear depth could be predicted well using the double-sinusoidal function for cross-shear (r2=0.983). The friction data were then used to calculate the work to remove a unit particle by integrating the frictional force over the directional sliding distance. Using the wear volumes, determined for both longitudinal and perpendicular motion directions, the work to remove a unit volume of material was qy = 8.473 × 108 J/mm3 and qx = 1.321 × 108 J/mm3, respectively. Hence, 6.4 times more work was necessary to remove a unit wear volume in the direction of principal motion (i.e. along the molecular fibril orientation) than 90° perpendicular to it. In the future, these findings will be implemented in computational models to assess wear.

Entities:  

Keywords:  Cross-Shear; Polyethylene; Unit Work; Wear Factor; Wear Model

Year:  2013        PMID: 23794761      PMCID: PMC3685199          DOI: 10.1016/j.wear.2013.01.069

Source DB:  PubMed          Journal:  Wear        ISSN: 0043-1648            Impact factor:   3.892


  9 in total

1.  Prediction of total knee arthroplasty polyethylene wear using the wear index.

Authors:  Hiromasa Miura; Hidehiko Higaki; Yoshitaka Nakanishi; Taro Mawatari; Takaaki Moro-Oka; Teruo Murakami; Yukihide Iwamoto
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

2.  Molecular orientation of ultrahigh molecular weight polyethylene induced by various sliding motions.

Authors:  Sharadha Sambasivan; Daniel A Fischer; Ming C Shen; Stephen M Hsu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-08-15       Impact factor: 3.368

3.  Computational wear prediction of a total knee replacement from in vivo kinematics.

Authors:  Benjamin J Fregly; W Gregory Sawyer; Melinda K Harman; Scott A Banks
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

4.  Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding.

Authors:  V Saikko
Journal:  Proc Inst Mech Eng H       Date:  2006-10       Impact factor: 1.617

5.  Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE.

Authors:  Lu Kang; Alison L Galvin; Thomas D Brown; Zhongmin Jin; John Fisher
Journal:  J Biomech       Date:  2007-10-22       Impact factor: 2.712

6.  Computer model to predict subsurface damage in tibial inserts of total knees.

Authors:  S Sathasivam; P S Walker
Journal:  J Orthop Res       Date:  1998-09       Impact factor: 3.494

7.  Tractive forces during rolling motion of the knee: implications for wear in total knee replacement.

Authors:  M A Wimmer; T P Andriacchi
Journal:  J Biomech       Date:  1997-02       Impact factor: 2.712

8.  Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application.

Authors:  Curtis M Goreham-Voss; Philip J Hyde; Richard M Hall; John Fisher; Thomas D Brown
Journal:  J Biomech       Date:  2010-06-18       Impact factor: 2.712

9.  In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard.

Authors:  V Ngai; T Schwenke; M A Wimmer
Journal:  Proc Inst Mech Eng H       Date:  2009-10       Impact factor: 1.617

  9 in total
  7 in total

1.  Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners.

Authors:  Steven P Mell; Spencer Fullam; Markus A Wimmer; Hannah J Lundberg
Journal:  Proc Inst Mech Eng H       Date:  2018-04-15       Impact factor: 1.617

2.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

3.  The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Authors:  Steven P Mell; Markus A Wimmer; Hannah J Lundberg
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

Review 4.  Biotribology of artificial hip joints.

Authors:  Francesca Di Puccio; Lorenza Mattei
Journal:  World J Orthop       Date:  2015-01-18

5.  Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters.

Authors:  Steven P Mell; Markus A Wimmer; Joshua J Jacobs; Hannah J Lundberg
Journal:  J Mech Behav Biomed Mater       Date:  2021-10-28

6.  Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Authors:  Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

7.  Wear behavior of an unstable knee: stabilization via implant design?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  Biomed Res Int       Date:  2014-09-09       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.