Literature DB >> 11934414

Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators.

Vesa Saikko1, Olof Calonius.   

Abstract

Joint simulators are important tools in wear studies of prosthetic joint materials. The type of motion in a joint simulator is crucial with respect to the wear produced. It is widely accepted that only multidirectional motion yields realistic wear for polyethylene acetabular cups. Multidirectionality, however, is a wide concept. The type of multidirectional motion varies considerably between simulators, which may explain the large differences in observed wear rates. At present, little is known about the relationship between the type of multidirectional motion and wear. One illustrative way to compare the motions of various hip simulators is to compute tracks made on the counterface by selected points of the surface of the femoral head and acetabular cup due to the cyclic relative motion. A new computation method, based on Euler angles, was developed, and used to compute slide tracks for the three-axis motion of the hip joint in walking, and for two hip simulators, the HUT-3 and the biaxial rocking motion. The slide track patterns resulting from the gait waveforms were found to be similar to those produced by the HUT-3 simulator. This paper is the first to include a verification of the computed simulator tracks. The tracks were verified in the two simulators using sharp pins, embedded in acetabular cups, engraving distinct grooves onto the femoral heads. The engravings were identical to the computed tracks. The results clearly differed from earlier computations by another research group. This study is intended to start a thorough investigation of the relationship between the type of multidirectional motion and wear.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11934414     DOI: 10.1016/s0021-9290(01)00224-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE.

Authors:  Lu Kang; Alison L Galvin; Thomas D Brown; Zhongmin Jin; John Fisher
Journal:  J Biomech       Date:  2007-10-22       Impact factor: 2.712

2.  Distinctive damage patterns on THA metal bearing surfaces: case studies.

Authors:  Anneliese D Heiner; Nishant M Tikekar; Karen M Kruger; John J Lannutti; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2014

3.  Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Authors:  Kevin J Warburton; John B Everingham; Jillian L Helms; Andrew J Kazanovicz; Katherine A Hollar; Jeff D Brourman; Steven M Fox; Trevor J Lujan
Journal:  J Orthop Res       Date:  2017-11-14       Impact factor: 3.494

4.  How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study.

Authors:  Robin Pourzal; Christopher B Knowlton; Deborah J Hall; Michel P Laurent; Robert M Urban; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2016-02-18       Impact factor: 4.176

5.  The tribological difference between biomedical steels and CoCrMo-alloys.

Authors:  Alfons Fischer; Sabine Weiss; Markus A Wimmer
Journal:  J Mech Behav Biomed Mater       Date:  2012-01-25

6.  Biotribological evaluation of artificial disc arthroplasty devices: influence of loading and kinematic patterns during in vitro wear simulation.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Janet Basson; Jens Schwiesau; Bernhard Fritz; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2008-12-03       Impact factor: 3.134

7.  Effect of motion inputs on the wear prediction of artificial hip joints.

Authors:  Feng Liu; John Fisher; Zhongmin Jin
Journal:  Tribol Int       Date:  2013-07       Impact factor: 4.872

8.  Hard Chrome-Coated and Fullerene-Doped Metal Surfaces in Orthopedic Bearings.

Authors:  Robert Sonntag; Katja Feige; Claudia Beatriz Dos Santos; Jan Philippe Kretzer
Journal:  Materials (Basel)       Date:  2017-12-20       Impact factor: 3.623

9.  Experimental and analytical validation of a modular acetabular prosthesis in total hip arthroplasty.

Authors:  Francisco Romero; Farid Amirouche; Luke Aram; Mark H Gonzalez
Journal:  J Orthop Surg Res       Date:  2007-05-16       Impact factor: 2.359

10.  Similar Biomechanical Behavior in Gait Analysis between Ceramic-on-Ceramic and Ceramic-on-XLPE Total Hip Arthroplasties.

Authors:  Athanasios Triantafyllou; Georgios Papagiannis; Vasileios S Nikolaou; Panayiotis J Papagelopoulos; George C Babis
Journal:  Life (Basel)       Date:  2021-12-08
  10 in total