Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses.

C Quental1, J Folgado, P R Fernandes, J Monteiro.   

Abstract

The wear of ultra-high molecular weight polyethylene, UHMWPE, components has been associated with the failure of joint prostheses in the hip, knee, and shoulder. Considering that in vitro experiments are generally too expensive and time-consuming, computational models are an attractive alternative to study the wear behavior of UHMWPE components. The objective of the present study was to develop a computational wear model to evaluate the wear resistance of anatomical and reverse shoulder prostheses. The effects of the wear law and the updating of the UHMWPE surface on the prediction of wear were also considered. Apart from Archard's law, a new wear law, so-called second generation law, which includes the concept of cross-shear and a pressure-independent wear factor, was considered. The wear analyses were performed considering three shoulder joint motions. The muscle and joint reaction forces applied were estimated by an inverse biomechanical model of the upper limb. The results show that abrasive wear is as important for the reverse components as it is for the anatomical. Nevertheless, the volumetric wears estimated over 1 year are within the range considered clinically desirable to reduce the risk of osteolysis. For the anatomical components, the predictions from Archard's law compare better, than those of the second generation law, to the experimental and clinical data available in the literature. Yet, the opposite result is obtained for the reverse components. From the numerical point of view, an updating procedure for the UHMWPE surface is mandatory to improve the numerical predictions.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25362522     DOI: 10.1007/s11517-014-1221-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  43 in total

1.  Observations on retrieved glenoid components.

Authors:  Ralph Hertel; F T Ballmer
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

2.  The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis.

Authors:  Sara Barreto; João Folgado; Paulo R Fernandes; Jacinto Monteiro
Journal:  J Biomech Eng       Date:  2010-05       Impact factor: 2.097

3.  Finite element models of total shoulder replacement: application of boundary conditions.

Authors:  Andrew R Hopkins; Ulrich N Hansen; Andrew A Amis
Journal:  Comput Methods Biomech Biomed Engin       Date:  2005-02       Impact factor: 1.763

4.  Multibody system of the upper limb including a reverse shoulder prosthesis.

Authors:  C Quental; J Folgado; J Ambrósio; J Monteiro
Journal:  J Biomech Eng       Date:  2013-11       Impact factor: 2.097

5.  Comparison of hexahedral and tetrahedral elements in finite element analysis of the foot and footwear.

Authors:  Srinivas C Tadepalli; Ahmet Erdemir; Peter R Cavanagh
Journal:  J Biomech       Date:  2011-07-13       Impact factor: 2.712

6.  Polyethylene wear in retrieved reverse total shoulder components.

Authors:  Judd S Day; Daniel W MacDonald; Madeline Olsen; Charles Getz; Gerald R Williams; Steven M Kurtz
Journal:  J Shoulder Elbow Surg       Date:  2011-07-02       Impact factor: 3.019

7.  A new formulation for the prediction of polyethylene wear in artificial hip joints.

Authors:  F Liu; A Galvin; Z Jin; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  2011-01       Impact factor: 1.617

8.  Wear analysis in anatomical and reversed shoulder prostheses.

Authors:  N S Ribeiro; J Folgado; P R Fernandes; J Monteiro
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-06-21       Impact factor: 1.763

9.  Modelling cartilage mechanobiology.

Authors:  Dennis R Carter; Marcy Wong
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2003-09-29       Impact factor: 6.237

10.  Observations on retrieved glenoid components from total shoulder arthroplasty.

Authors:  Shane J Nho; Denis Nam; Owen L Ala; Edward V Craig; Russell F Warren; Timothy M Wright
Journal:  J Shoulder Elbow Surg       Date:  2009-02-14       Impact factor: 3.019

View more
  2 in total

1.  Predicting long-term wear performance of hard-on-hard bearing couples: effect of cup orientation.

Authors:  S Shankar; K Gowthaman; M S Uddin
Journal:  Med Biol Eng Comput       Date:  2015-12-30       Impact factor: 2.602

2.  Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.

Authors:  R Nithyaprakash; S Shankar; M S Uddin
Journal:  Med Biol Eng Comput       Date:  2017-11-02       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.