Literature DB >> 17851666

Dual-source computed tomography in patients with acute chest pain: feasibility and image quality.

Thomas Schertler1, Hans Scheffel, Thomas Frauenfelder, Lotus Desbiolles, Sebastian Leschka, Paul Stolzmann, Burkhardt Seifert, Thomas G Flohr, Borut Marincek, Hatem Alkadhi.   

Abstract

The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1+/-16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1+/-6 HU comparing right and left coronary artery and 56+/-9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291+/-65 HU in the ascending aorta, 334+/-93 HU in the pulmonary trunk, and 285+/-66 HU and 268+/-67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17851666      PMCID: PMC2077913          DOI: 10.1007/s00330-007-0724-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


Introduction

Acute chest pain represents one of the most difficult diagnostic challenges in emergency medicine. Chest pain history alone often cannot identify a group of patients who could be treated without further diagnostic testing [1], and triage decisions based on initial cardiac enzyme levels [2] and electrocardiography (ECG) [3] are often insufficient. Imaging may improve patient triage by decreasing delay in diagnosis and treatment and thus morbidity and mortality [4, 5]. Most studies [6-8] have focused on patients being suspected of having acute coronary syndrome, but did not include additional differential diagnoses such as aortic dissection or pulmonary embolism, conditions that may clinically mimic coronary syndromes [9]. Multi-detector row computed tomography (CT) angiography is widely accepted and routinely used as a primary tool in the emergency assessment of pulmonary embolism [10] and aortic dissection [11]. In addition, 64-slice CT coronary angiography has demonstrated the capability to diagnose and to rule-out coronary artery disease (CAD) [12, 13]. Some recent studies have shown that ECG-gated multi-detector row CT is logistically feasible [14] and yields promising results as a modality for evaluating chest pain patients with cardiac and non-cardiac disease in the emergency setting [15, 16]. Even though using 64-slice CT scanner technology, however, patients with elevated heart rates require medical heart rate control prior to CT coronary angiography by administering beta-blockers and/or benzodiazepines [8, 13, 17]. Dual-source CT (DSCT) represents the most recent scanner technology and is characterized by two tubes and two detectors that are mounted in orthogonal orientation onto the gantry. As compared to 64-slice CT, this scanner configuration maintains a consistently high spatial resolution while enabling ECG-gated imaging with an increased temporal resolution of 83 ms [18]. First studies have shown robust results of DSCT angiography (DSCTA) regarding image quality of cardiac structures even at high heart rates [19-21]. The purpose of this study was to investigate the feasibility and image quality of ECG-gated DSCTA of the chest as a tool to evaluate cardiac and non-cardiac causes of acute chest pain in patients presenting to the emergency department.

Materials and methods

Patient population

Sixty consecutive patients (32 females, 28 males, mean age 58.1±16.3 years, age range 26–84 years) were prospectively included in this study. Intake was performed on weekdays from 7 am to 7 pm from August to October 2006. All patients suffered from acute chest pain and were referred to our department to diagnose or to rule out pulmonary embolism (n=56) or aortic dissection (n=4). Inclusion criteria were acute chest pain >5 min within the previous 24 h and/or elevated serum D-dimer levels. Dyspnea and hemodynamic instability were not considered exclusion criteria. Similarly, all patients irrespective of their mean or regularity of heart rate and irrespective of their ability to perform breath-hold were included. Exclusion criteria included pregnancy, previous adverse reaction to iodinated contrast agent, nephropathy (serum creatinine >1.3 mg/dl), elevated troponine-I or creatine kinase-MB level in the initial blood sample, initial diagnostic ECG changes indicating an acute coronary syndrome (i.e., ST elevation or depression >1 mm, T-wave inversion >4 mm in >2 anatomically contagious leads), and interference with standard clinical care of patients. The study was approved by the local ethics committee; informed consent was obtained.

Scan protocol and data reconstruction

All CT examinations were performed on a DSCT scanner (Somatom Definition, Siemens Medical Solutions, Forchheim, Germany). First, a single non-enhanced low-dose scan at the level of the aortic root was obtained. In this slice, a region of interest (ROI) was set in the lumen of the aorta for monitoring intraluminal contrast enhancement. The delay from start of contrast material injection to start of scanning was planned using the bolus-tracking technique. A total of 110 ml iodinated contrast material (iodixanol, Visipaque 320; 320 mg/ml, GE Healthcare, Buckinghamshire, UK) was administered at a flow rate of 4 ml/s via an 18-gauge needle placed into a superficial vein in the left antecubital fossa, followed by 30 ml saline solution at the same flow rate (4 ml/s). After reaching the preset contrast enhancement level of 80 Hounsfield Units (HU) in the ROI, a breath-hold signal was given and the scan was initiated automatically after a delay of 6 s. A topogram was used for planning the examination and determining the scan range. Data acquisition was performed using a dedicated biphasic chest pain protocol. As illustrated in Fig. 1, the lower chest including the heart was scanned with a tube current time of 320 mAs while the upper chest was scanned with a tube current time product of 160 mAs. The borderline between upper and lower scan range was set at approximately 2 cm below the carina. Data acquisition was performed in a cranio-caudal direction. Acquisition parameters were as follows: detector collimation 2×32×0.6 mm by using a z-flying focal spot for the simultaneous acquisition of 2×64 overlapping 0.6-mm slices, gantry rotation time 330 ms, and tube potential 120 kV. The pitch varied according to the patient's heart rate and ranged from 0.2–0.43, with higher pitch at higher heart rates. ECG-pulsing for radiation dose reduction [22] was applied in all patients. At mean heart rates below 60 bpm, full tube current was applied from 60 to 70%, at 61–70 bpm from 50 to 80%, and at heart rates above 70 from 30 to 80% of the R-R interval.
Fig. 1

Scan topogram illustrating planning of the chest pain protocol. The scan range covered the entire chest (red box). Premonitoring for bolus tracking was performed at the level of the aortic root (white line). The border for full tube current for the heart and half tube current for the upper lung is set approximately 2 cm below the tracheal bifurcation. It is delimited by a virtual horizontal line connecting the upper ends of the blue boxes on both sides

Scan topogram illustrating planning of the chest pain protocol. The scan range covered the entire chest (red box). Premonitoring for bolus tracking was performed at the level of the aortic root (white line). The border for full tube current for the heart and half tube current for the upper lung is set approximately 2 cm below the tracheal bifurcation. It is delimited by a virtual horizontal line connecting the upper ends of the blue boxes on both sides Retrospective ECG-gating for phase synchronization was used. For the heart, CT data sets were reconstructed at 70% of the R-R interval with a slice thickness of 0.75 mm (increment 0.5 mm) by using a medium soft-tissue convolution kernel (B26f) (mean field of view, FoV: 151±17 mm, image matrix 512×512). If considered necessary, additional images were reconstructed in 5% steps using the same parameters within the time window of full tube current. Images of the mediastinum (mean FoV: 293±43 mm) including the aorta and pulmonary arteries were reconstructed with a slice thickness of 1 mm (increment 0.8 mm) by using a medium soft-tissue convolution kernel (B30f), and images of the lung were reconstructed with a slice thickness of 2 mm (increment 1.5 mm) by using a sharp convolution kernel (B60f, same FoV as for the mediastinum). All images were transferred to a second Wizard (Siemens) equipped with cardiac post-processing software (Syngo Circulation, Siemens).

Data analysis

All data were qualitatively evaluated regarding image quality and artifacts of different thoracic structures by two independent readers who are both experienced in cardiovascular radiology. This evaluation was performed on transverse source images, multi-planar reformations (MPR), curved MPR, and thin-slab maximum intensity projections.

Image quality and artifacts-lung parenchyma

Image quality of lung parenchyma was independently rated using a two-point scale, adapted from a previous publication [23]. Lung parenchyma allowing diagnostic assessment due to distinct anatomic details of bronchial and parenchymal structures without significant artifacts and noise was rated with a score of 1 (diagnostic). Lung parenchyma with artifacts or noise causing reduction of image quality and diagnostic value was rated with a score of 2 (non-diagnostic). Artifacts were rated to quantify the cranio-caudal distribution of artifacts within the lung parenchyma for the right and left lung separately in coronal MPR. Because of the different tube current at upper and lower parts along the z-axis (see Fig. 1), the following scores were separately applied for the apex and the basis of the lung, respectively: 1= no artifacts, 2= breathing artifacts (stair step artifacts), 3= ECG-gating (i.e., synchronization or interpolation artifacts), and 4= noise artifacts. If breathing and ECG-gating artifacts appeared at the same time in one patient, the artifact with the worst impact on image quality was noted.

Image quality and artifacts-vascular structures

Image quality of thoracic vascular structures was independently rated using the same two-point scale [23] as used for the rating of the lung parenchyma. Regarding the thoracic aorta, a score of 1 (diagnostic) indicated confident evaluation of the ascending aorta, the aortic arch, and descending aorta. Regarding pulmonary arteries, a score of 1 indicated confident evaluation of central, lobar, segmental, or subsegmental pulmonary arteries. Regarding coronary arteries, a score of 1 represented confident depiction (homogenous attenuation; no artifacts decreasing coronary analysis) of the right coronary artery (RCA), left main artery (LMA), left anterior descending artery (LAD), left circumflex artery (LCX), and their side branches. A score of 2 indicated decreased image quality of thoracic vascular structures with severe impairment of diagnostic value (non-diagnostic) due to breathing, motion, or ECG-gating artifacts.

Image noise and attenuation-vascular structures

Image noise was determined as the standard deviation of attenuation in a ROI placed in the ascending aorta [24]. Contrast attenuation was measured in each patient in the ascending aorta, pulmonary trunk, LMA, proximal segment of the RCA, and right and left ventricle. Image noise and contrast attenuation were assessed using a circular ROI positioned exactly within the vessel or ventricular lumen while avoiding superimposition or partial volume effects from the vessel wall or myocardium. Measurements of the ascending aorta and pulmonary trunk as well as of the right and left ventricle were performed on the same transverse image, while the ROI in the coronary arteries was individually placed on separate transverse images.

Imaging findings

Imaging findings indicating the possible underlying cause of acute chest pain were documented in each patient by both readers in consensus.

Statistical analysis

Statistical analysis was performed using commercially available software (SPSS 11.5, SPSS Inc., Il). Quantitative variables are expressed as mean ± standard deviation (SD) including 95% confidence intervals (CI) or range when appropriate. Categorical data were expressed as frequencies or percentages. Inter-observer agreement (kappa statistics) for image quality ratings was calculated. Two-tailed Student's t test for paired samples was used to explore significant differences in vessel attenuation among the ascending aorta, RCA, LMA, pulmonary trunk, and right and left ventricle. Intra-individual differences regarding vessel attenuation among the different vascular territories were performed using pairwise comparisons. Bonferroni correction for multiple comparisons was made, and a P-value <0.003 was considered statistically significant.

Results

All CT scans were well tolerated and were successfully performed in all 60 patients without complications. All patients had a sinus rhythm, and the average heart rate during data acquisition was 74.9±19.0 beats per minute (bpm) (range 45-130 bpm). No beta receptor antagonists or benzodiazepines were administered prior to CT; 13 patients (22%) took oral beta blockers as part of their baseline medication at the time of the scan. Mean scan time was 12.2±2.3 s (range 9.7–17.5 s) and mean scan length was 24.1±2.1 cm (range 19.3–29.7 cm). The reconstruction interval used for image reading was 70% of the R-R interval. In seven patients it was considered necessary to reconstruct additional data sets in 5% intervals within the window of full tube current to obtain images with diagnostic quality. Image quality of lung parenchyma was rated as being diagnostic (score 1) by both readers in all 60 patients (100%; excellent inter-observer agreement, kappa =1.0), and pathology both at upper and lower lung parts could be diagnosed or excluded in all 60 patients. Lung parenchyma was rated by both readers as being artifact-free in 42 patients (70%). Breathing artifacts causing stair-step artifacts were encountered in nine patients (15%) by one reader and eight (13%) of these nine patients by the other reader (excellent inter-observer agreement, kappa =0.93). Breathing artifacts were exclusively found at the lung base, i.e., at the end of the breath-hold period. ECG-gating-related artifacts were found in ten patients (17%) by one reader, and in nine (15%) of these ten patients by the other reader (excellent inter-observer agreement, kappa =0.84). The two types of artifacts were not encountered in the same patient, and image quality was diagnostic despite the artifacts. Image quality of the thoracic aorta was rated by both readers as being diagnostic (score 1) in all 60 patients (100%; excellent inter-observer agreement, kappa =1.0), and pathologies of the thoracic aorta could be diagnosed or excluded by both readers in all 60 patients. Both readers rated image quality of the pulmonary arteries in the one (i.e., the same) patient (2%) as being non-diagnostic (score 2) due to insufficient attenuation of segmental and subsegmental pulmonary arteries. In this patient, attenuation did not allow excluding segmental or subsegmental pulmonary embolism, while attenuation in the pulmonary trunk and right and left lobar artery was considered sufficient for diagnosis or exclusion of central and lobar pulmonary embolism. In this patient, image quality of the coronary arteries was considered as being diagnostic by both readers. Image quality of coronary arteries was rated by both readers as being diagnostic (score 1) in the same 58 patients (97%; excellent inter-observer agreement, kappa =1.0). In the remaining two patients (3%), image quality of the coronary arteries was considered by both readers as being non-diagnostic (score 2) due to ECG-gating-related artifacts (mean heart rate 71 bpm, ranging from 50 to 84 bpm during scanning) in one and severe image noise due to obesity (body mass index 40.4 kg/m2) in the other. In both patients, both readers rated image quality of the pulmonary arteries as being diagnostic. Mean image noise in the ascending aorta (mean ROI size 3.6±0.2 cm2) was 29.8±5.6. Mean attenuation in the ascending aorta (same ROI and same ROI size as for measurements of image noise) was 291±65 HU (95% CI: 274–308 HU), mean attenuation in the pulmonary trunk (mean ROI size 2.4±0.2 cm2) was 334±93 HU (95% CI: 310–358 HU), mean attenuation in the proximal RCA (mean ROI size 0.14±0.02 cm2) was 285±66 HU (95% CI: 268–302 HU), and mean attenuation in the LMA (mean ROI size 0.12 cm2±0.01) was 286±67 HU (95% CI: 269–304 HU). Mean attenuation in the right ventricle (mean ROI size 2.6±0.2 cm2) was 313±89 HU (95% CI: 290–336 HU) and mean attenuation in the left ventricle (mean ROI size 2.6±0.2 cm2) was 277±66 HU (95% CI: 260–294 HU) (Fig. 2).
Fig. 2

Mean attenuation values (HU) within different vessels indicating a relatively homogenous contrast distribution between the different thoracic vascular territories. RCA = right coronary artery; LMA = left main coronary artery

Mean attenuation values (HU) within different vessels indicating a relatively homogenous contrast distribution between the different thoracic vascular territories. RCA = right coronary artery; LMA = left main coronary artery No significant differences regarding attenuation were found between the RCA and LMA (P=n.s.), and between the ascending aorta and both coronary arteries (P=n.s.). No significant differences in attenuation were present between the right and left ventricle (P=n.s.), between the right ventricle and ascending aorta (P=n.s.), between the right ventricle and pulmonary trunk (P=n.s.), and between the right ventricle and the RCA (P=n.s.) and LMA (P=n.s.). Similarly, there were no significant differences in attenuation between the left ventricle and ascending aorta (P=n.s.), and between left ventricle and LMA (P=n.s.) and RCA (P=n.s.). Significant differences were only found between the pulmonary trunk and ascending aorta (P <0.003), between the pulmonary trunk and the RCA and LMA (P<0.003), respectively, and between the left ventricle and pulmonary trunk (P<0.003). Pairwise comparisons of mean intra-individual differences regarding vessel attenuation were small and ranged between 1.18±5.86 HU comparing the right and left coronary artery and 56.45±8.96 HU comparing the pulmonary trunk and left ventricle (Table 1).
Table 1

Pairwise intra-individual comparisons between different thoracic vascular territories

 Mean differenceStandard deviation95% confidence interval
Lower boundaryUpper boundary
AortaPulmonary trunk-4311-75-11
AortaRCA65-1022
AortaLCA54-817
AortaRight ventricle-2313-6318
AortaLeft ventricle145-330
Pulmonary trunkRCA49111682
Pulmonary trunkLCA47121283
Pulmonary trunkRight ventricle2012-1657
Pulmonary trunkLeft ventricle5792984
RCALCA-16-1917
RCARight ventricle-2813-6913
RCALeft ventricle85-824
LCARight ventricle-2714-7015
LCALeft ventricle96-1028

RCA = right coronary artery; LCA = left coronary artery

Pairwise intra-individual comparisons between different thoracic vascular territories RCA = right coronary artery; LCA = left coronary artery No pathologic findings were found in 33 patients (55%), whereas various pathologies of the aorta, pulmonary and coronary arteries, lung, and mediastinum were present in 27 patients (45%) (Table 2, Figs. 3, 4, 5).
Table 2

Imaging findings in the study population

DiagnosisNumber of patients (n=60)
No pathology33
Pulmonary embolism11
Aortic pathology, total5
 Dissection type B3
 Pseudoaneurysm of the aortic arch1
 Plaque rupture1
Coronary pathology, total3
 Significant stenosis of the LAD2
 Occlusion of the RCA1
Pulmonary consolidation3
Pericarditis/pericardial effusion2
Seropneumothorax1
Non-small cell lung cancer1
Synovial cell carcinoma1

LAD, left anterior descending artery; RCA, right coronary artery

Fig. 3

A 63-year-old female patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (RCX) allow excluding significant coronary stenosis in this patient. Mean heart rate during DSCTA was 71 bpm. (b) Thin-slab transverse maximum intensity projection shows no evidence of pulmonary embolism. (c) Transverse image at the level of the pulmonary trunk demonstrates acute aortic dissection type B (arrow) with mild left-sided pleural effusion

Fig. 4

A 58-year-old female patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (LCX) demonstrate normal coronary arteries and no evidence of stenosis. Mean heart rate during DSCTA was 63 bpm. (b) Thin-slab transverse maximum intensity projection show bilateral pulmonary embolism (arrows). (c) Oblique-sagittal thin-slab maximum intensity projection demonstrates the thoracic aorta without evidence of disease

Fig. 5

A 71-year-old male patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (LCX) show occlusion of the proximal RCA (long arrow) and vessel wall calcifications without significant stenosis in the proximal and middle segment of the LAD and LCX (short arrows). Mean heart rate during DSCTA was 73 bpm. (b) Thin-slab transverse maximum intensity projection demonstrates normal opacification of pulmonary arteries with no evidence of embolism. (c) Oblique-sagittal thin-slab maximum intensity projection demonstrates the thoracic aorta with minimal atherosclerotic wall changes, but with no evidence of potential causes for acute chest pain

Imaging findings in the study population LAD, left anterior descending artery; RCA, right coronary artery A 63-year-old female patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (RCX) allow excluding significant coronary stenosis in this patient. Mean heart rate during DSCTA was 71 bpm. (b) Thin-slab transverse maximum intensity projection shows no evidence of pulmonary embolism. (c) Transverse image at the level of the pulmonary trunk demonstrates acute aortic dissection type B (arrow) with mild left-sided pleural effusion A 58-year-old female patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (LCX) demonstrate normal coronary arteries and no evidence of stenosis. Mean heart rate during DSCTA was 63 bpm. (b) Thin-slab transverse maximum intensity projection show bilateral pulmonary embolism (arrows). (c) Oblique-sagittal thin-slab maximum intensity projection demonstrates the thoracic aorta without evidence of disease A 71-year-old male patient admitted to the emergency department with acute chest pain. (a) Curved multiplanar reformations along the centerline of the right coronary (RCA), left anterior descending (LAD), and the left circumflex artery (LCX) show occlusion of the proximal RCA (long arrow) and vessel wall calcifications without significant stenosis in the proximal and middle segment of the LAD and LCX (short arrows). Mean heart rate during DSCTA was 73 bpm. (b) Thin-slab transverse maximum intensity projection demonstrates normal opacification of pulmonary arteries with no evidence of embolism. (c) Oblique-sagittal thin-slab maximum intensity projection demonstrates the thoracic aorta with minimal atherosclerotic wall changes, but with no evidence of potential causes for acute chest pain

Discussion

Our study demonstrates that DSCT allows performing an ECG-gated chest examination for visualizing the different thoracic vascular territories at the same time-by employing an adjusted contrast media protocol-within a reasonable breath-hold period, and thus provides a diagnostic image quality in almost all patients. One of the most important findings of this study is that diagnostic data of coronary arteries could be obtained without foregoing heart rate control.

Contrast media protocol and scan time

With increasing gantry rotation times and faster volume coverage of newer CT scanners, scan times successively shorten and higher injection rates are required to achieve sufficient contrast in the vascular territory of interest. Similar to a previous 64-slice CT study [15], we have set the ROI for bolus tracking in the ascending aorta. With a relatively low threshold of 80 HU above which the scan was initiated, a homogenous attenuation in both aortic/coronary and pulmonary arteries could be achieved. By doing so, we aimed at the time interval where the contrast enhancement curve of the pulmonary circulation overlaps with enhancement of the aorta [25]. This has also resulted in comparable attenuation in left and right cardiac cavities. Recommended mean attenuation values for diagnostic image quality are approximately 300 HU for the pulmonary arteries [26] and 250–350 HU in the ascending aorta and coronary arteries [27, 28]. We obtained a mean attenuation of 291 HU in the ascending aorta, 334 HU in the pulmonary trunk, 285 HU in the RCA, and 286 HU in the LMA with only small intra- and inter-individual variations. These attenuation values were considered diagnostic in 98% of our patients and are comparable to previously published data [15, 29]. We encountered only one patient with non-diagnostic attenuation of segmental and subsegmental pulmonary arteries. However, this may have been also caused by other reasons negatively affecting contrast attenuation in pulmonary arteries such as Valsalva maneuver [30]. The other major issue for CT in acute chest pain represents the issue of scan duration. As ECG-gated CT requires low pitch [31], scan time is increased as compared to non-gated chest CT examinations. This, however, negatively affects image quality by making examinations more prone to breathing artifacts. This holds particularly true for patients with acute chest pain who often suffer from dyspnea. In our study, mean scan time was approximately 12 s, which represents a further improvement as compared to a mean scan time of 21 s with 64-slice CT [15].

Role of CT in the diagnostic pathway of acute chest pain

Figure 6 represents a simplified flow-chart of a generally accepted clinical pathway for patients with cardiac and non-cardiac causes of acute chest pain [9, 32, 33]. While CT is the accepted reference modality for the diagnosis and exclusion of pulmonary embolism and aortic dissection [10, 11], the role of CT in patients with a suspected cardiac cause for chest pain is currently under investigation. Gallagher and colleagues [6] have shown that 64-slice CT has accuracy that is comparable to that of stress nuclear imaging for the detection of acute coronary syndrome in low-risk patients with negative serial ECG and biomarker results. Hoffmann and coworkers [8] have demonstrated that 64-slice CT has good performance characteristics for ruling out acute coronary syndromes in patients presenting to the emergency department with acute chest pain. The authors demonstrated in patients in whom initial triage was inconclusive that the absence of coronary artery plaque or significant stenosis on CT angiography had an excellent negative predictive value for the subsequent diagnosis of acute coronary syndrome. Furthermore, in those patients with CAD on CT, the extent of coronary atherosclerotic plaque provided incremental information to standard baseline patient variables and clinical risk assessment. Goldstein and colleagues [7] have shown that 64-slice CT coronary angiography is able to definitely establish or exclude CAD as the cause of acute chest pain. The high negative predictive value of the studies suggests that CT coronary angiography may be useful for facilitating and optimizing triage of patients with acute chest pain and/or inconclusive initial emergency department evaluation [7, 8].
Fig. 6

Flow chart of a generally accepted clinical pathway for patients with cardiac and non-cardiac causes of acute chest pain. CT represents the standard of reference in patients with suspicion of acute aortic syndromes or pulmonary embolism (light gray boxes). The added value of CT in the evaluation of acute coronary syndrome has been already demonstrated [8] (moderate gray box). The potential future role of CT in patients with acute chest pain might be at an even earlier point of diagnostic work-up (dark gray boxes) to rule out life-threatening coronary, pulmonary, and aortic disease and to guide adequate therapeutic interventions

Flow chart of a generally accepted clinical pathway for patients with cardiac and non-cardiac causes of acute chest pain. CT represents the standard of reference in patients with suspicion of acute aortic syndromes or pulmonary embolism (light gray boxes). The added value of CT in the evaluation of acute coronary syndrome has been already demonstrated [8] (moderate gray box). The potential future role of CT in patients with acute chest pain might be at an even earlier point of diagnostic work-up (dark gray boxes) to rule out life-threatening coronary, pulmonary, and aortic disease and to guide adequate therapeutic interventions

Study limitations

We included only a relatively small number of patients and thus a small number of pathologies. Second, our study lacks a standard end-point to assess the final diagnosis and misses comparison with the reference standard invasive coronary angiography for investigating CAD for which diagnostic accuracy could be calculated. However, only a minority of our patients underwent invasive coronary angiography because in our emergency department standard management in patients with suspected acute coronary syndrome directly undergoing invasive coronary angiography without prior CT. That is in line with most studies involving patients referred to the emergency department [34]. Third, we did not investigate the optimal contrast media technique for obtaining homogenous contrast attenuation of different thoracic vascular territories. It remains to be determined if the use of the test bolus technique would yield better results with regard to vessel opacification. Finally, it needs to be assessed whether caudo-cranial or caudo-cranial scan direction will result in better image quality.

Conclusion

First experience indicates that DSCTA is feasible in patients with acute chest pain and provides diagnostic image quality of the aorta, pulmonary arteries, and coronary artery system as well as of the lung parenchyma and mediastinum in a patient population without foregoing heart rate control. A dedicated contrast media protocol allows for homogenous attenuation of the different thoracic vascular territories.
  34 in total

Review 1.  Evaluation of the patient with acute chest pain.

Authors:  T H Lee; L Goldman
Journal:  N Engl J Med       Date:  2000-04-20       Impact factor: 91.245

Review 2.  Multislice CT angiography.

Authors:  M Prokop
Journal:  Eur J Radiol       Date:  2000-11       Impact factor: 3.528

3.  The diagnostic accuracy of 64-slice computed tomography coronary angiography compared with stress nuclear imaging in emergency department low-risk chest pain patients.

Authors:  Michael J Gallagher; Michael A Ross; Gilbert L Raff; James A Goldstein; William W O'Neill; Brian O'Neil
Journal:  Ann Emerg Med       Date:  2006-09-15       Impact factor: 5.721

4.  ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Andreas Knez; Peter Boekstegers; Maximilian F Reiser; Christoph R Becker
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

5.  Determination of optimal timing window for pulmonary artery MDCT angiography.

Authors:  Chang Hyun Lee; Jin Mo Goo; Hyun Ju Lee; Kwang Gi Kim; Jung-Gi Im; Kyongtae T Bae; C H Lee; J M Goo; H J Lee; K G Kim; J-G Im; K T Bae
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

6.  MDCT in early triage of patients with acute chest pain.

Authors:  Udo Hoffmann; Antonio J Pena; Fabian Moselewski; Maros Ferencik; Suhny Abbara; Ricardo C Cury; Claudia U Chae; John T Nagurney
Journal:  AJR Am J Roentgenol       Date:  2006-11       Impact factor: 3.959

7.  Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients.

Authors:  A G d'Agostino; M Remy-Jardin; C Khalil; V Delannoy-Deken; T Flohr; A Duhamel; J Remy
Journal:  Eur Radiol       Date:  2006-04-12       Impact factor: 5.315

8.  A randomized controlled trial of multi-slice coronary computed tomography for evaluation of acute chest pain.

Authors:  James A Goldstein; Michael J Gallagher; William W O'Neill; Michael A Ross; Brian J O'Neil; Gilbert L Raff
Journal:  J Am Coll Cardiol       Date:  2007-02-12       Impact factor: 24.094

9.  Coronary multidetector computed tomography in the assessment of patients with acute chest pain.

Authors:  Udo Hoffmann; John T Nagurney; Fabian Moselewski; Antonio Pena; Maros Ferencik; Claudia U Chae; Ricardo C Cury; Javed Butler; Suhny Abbara; David F Brown; Alex Manini; John H Nichols; Stephan Achenbach; Thomas J Brady
Journal:  Circulation       Date:  2006-10-30       Impact factor: 29.690

10.  Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control.

Authors:  Hans Scheffel; Hatem Alkadhi; André Plass; Robert Vachenauer; Lotus Desbiolles; Oliver Gaemperli; Tiziano Schepis; Thomas Frauenfelder; Thomas Schertler; Lars Husmann; Jürg Grunenfelder; Michele Genoni; Philipp A Kaufmann; Borut Marincek; Sebastian Leschka
Journal:  Eur Radiol       Date:  2006-09-19       Impact factor: 5.315

View more
  12 in total

1.  High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization.

Authors:  Christoph Karlo; Sebastian Leschka; Robert Paul Goetti; Gudrun Feuchtner; Lotus Desbiolles; Paul Stolzmann; Andre Plass; Volkmar Falk; Borut Marincek; Hatem Alkadhi; Stephan Baumüller
Journal:  Eur Radiol       Date:  2010-07-31       Impact factor: 5.315

Review 2.  Dual-source cardiac computed tomography: image quality and dose considerations.

Authors:  Stephan Achenbach; Katharina Anders; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-02-26       Impact factor: 5.315

Review 3.  Radiation dose of cardiac CT--what is the evidence?

Authors:  Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-02-04       Impact factor: 5.315

4.  Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography.

Authors:  Dominik Ketelsen; Marie H Luetkhoff; Christoph Thomas; Matthias Werner; Markus Buchgeister; Ilias Tsiflikas; Anja Reimann; Christof Burgstahler; Andreas F Kopp; Claus D Claussen; Martin Heuschmid
Journal:  Eur Radiol       Date:  2008-07-22       Impact factor: 5.315

5.  Initial experience with a chest pain protocol using 320-slice volume MDCT.

Authors:  Patrick A Hein; Valentina C Romano; Alexander Lembcke; Juliane May; Patrik Rogalla
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

6.  Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT.

Authors:  Tobias De Zordo; Klemens von Lutterotti; Christian Dejaco; Peter F Soegner; Renate Frank; Friedrich Aigner; Andrea S Klauser; Christoph Pechlaner; U Joseph Schoepf; Werner R Jaschke; Gudrun M Feuchtner
Journal:  Eur Radiol       Date:  2011-08-28       Impact factor: 5.315

7.  Low-dose triple-rule-out using 320-row-detector volume MDCT--less contrast medium and lower radiation exposure.

Authors:  Tahir Durmus; Patrik Rogalla; Alexander Lembcke; Matthias R Mühler; Bernd Hamm; Patrick A Hein
Journal:  Eur Radiol       Date:  2011-02-24       Impact factor: 5.315

8.  Computed tomographic coronary angiography in patients with surgically treated type A aortic dissection: preliminary results.

Authors:  Andrea B Rosskopf; Rahel Bugmann; Volkhard Goeber; Daniel Ott; Otto Hess; Thierry Carrel; Hanno Hoppe
Journal:  Emerg Radiol       Date:  2010-05

Review 9.  Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings.

Authors:  Thomas Frauenfelder; Philippe Appenzeller; Christoph Karlo; Hans Scheffel; Lotus Desbiolles; Paul Stolzmann; Borut Marincek; Hatem Alkadhi; Thomas Schertler
Journal:  Eur Radiol       Date:  2008-11-18       Impact factor: 5.315

10.  Emergency cardiac CT for suspected acute coronary syndrome: qualitative and quantitative assessment of coronary, pulmonary, and aortic image quality.

Authors:  Jonathan D Dodd; Sanjeeva Kalva; Antonio Pena; Fabien Bamberg; Michael D Shapiro; Suhny Abbara; Ricardo C Cury; Thomas J Brady; Udo Hoffmann
Journal:  AJR Am J Roentgenol       Date:  2008-09       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.