Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients.

A G d'Agostino1, M Remy-Jardin, C Khalil, V Delannoy-Deken, T Flohr, A Duhamel, J Remy.   

Abstract

The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [+/-standard deviation (SD)] body mass index (BMI) of 24.47 (+/-4.64); (b) a mean (+/-SD) heart rate of 72.04 (+/-15.76) bpm; (c) a mean (+/-SD) scanning time of 18.3 (+/-2.73) s; (d) a mean (+/-SD) dose-length product (DLP) value of 260.57 (+/-83.67) mGy/cm; (e) an estimated average effective dose of 4.95 (+/-1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of interpolation artefacts was significantly linked to a low heart rate in affected patients. The overall image quality of CT scans was rated as diagnostic in 94 patients (89.5%) while 11 examinations (10.5%) were found to be partially nondiagnostic owing to the cyclic presence of severe interpolation artefacts, which can be compensated for by additional reconstructions at a different temporal window. In these cases, interpolation artefacts could have been avoided by reducing the pitch from 0.3 to 0.2 at the expense of increased patient dose. Low-dose ECG-gated CT angiograms of the chest can be obtained in routine clinical practice with 64-slice CT technology without altering the diagnostic value of CT scans.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16609862     DOI: 10.1007/s00330-006-0218-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

1.  Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Authors:  Emmanuel Coche; Alain Vlassenbroek; Véronique Roelants; William D'Hoore; Franck Verschuren; Louis Goncette; Baudouin Maldague
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

2.  Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations.

Authors:  Marco Das; Andreas Horst Mahnken; Georg Mühlenbruch; Achim Stargardt; Claudia Weiss; Dirk-Alexander Sennst; Thomas G Flohr; Rolf W Günther; Joachim Ernst Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

Review 3.  Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults--The Evidence Report. National Institutes of Health.

Authors: 
Journal:  Obes Res       Date:  1998-09

4.  Detrimental effects of beta-blockers in COPD: a concern for nonselective beta-blockers.

Authors:  Hanneke J van der Woude; Johan Zaagsma; Dirkje S Postma; Trea H Winter; Marinus van Hulst; René Aalbers
Journal:  Chest       Date:  2005-03       Impact factor: 9.410

5.  Dose reduction in multislice computed tomography.

Authors:  Walter Hundt; Friedemann Rust; Axel Stäbler; Heiko Wolff; Christoph Suess; Maximillian Reiser
Journal:  J Comput Assist Tomogr       Date:  2005 Jan-Feb       Impact factor: 1.826

6.  Individually adapted examination protocols for reduction of radiation exposure in chest CT.

Authors:  J E Wildberger; A H Mahnken; T Schmitz-Rode; T Flohr; A Stargardt; P Haage; S Schaller; R W Günther
Journal:  Invest Radiol       Date:  2001-10       Impact factor: 6.016

7.  Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.

Authors:  Koen Nieman; Filippo Cademartiri; Pedro A Lemos; Rolf Raaijmakers; Peter M T Pattynama; Pim J de Feyter
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

8.  ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses.

Authors:  Martin Heuschmid; Axel Kuettner; Stephen Schroeder; Tobias Trabold; Anja Feyer; Marcus D Seemann; Ronald Kuzo; Claus D Claussen; Andreas F Kopp
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Dose reduction in multidetector CT using attenuation-based online tube current modulation.

Authors:  Denis Tack; Viviane De Maertelaer; Pierre Alain Gevenois
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

View more
  15 in total

Review 1.  Today's and tomorrow's imaging and circulating biomarkers for pulmonary arterial hypertension.

Authors:  Marjorie Barrier; Jolyane Meloche; Maria Helena Jacob; Audrey Courboulin; Steeve Provencher; Sébastien Bonnet
Journal:  Cell Mol Life Sci       Date:  2012-03-25       Impact factor: 9.261

2.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

3.  Automatic tube current modulation technique for multidetector CT: is it effective with a 64-detector CT?

Authors:  Yoshinori Funama; Kazuo Awai; Masahiro Hatemura; Masamitchi Shimamura; Yumi Yanaga; Seitaro Oda; Yasuyuki Yamashita
Journal:  Radiol Phys Technol       Date:  2007-11-01

4.  ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain.

Authors:  Diana Litmanovich; Diana Litmanovitch; Giulia A Zamboni; Thomas H Hauser; Pei-Jan P Lin; Melvin E Clouse; Vassilios Raptopoulos
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

5.  Should lung scan be abandoned for pulmonary embolism diagnosis in the age of multislice spiral CT? Yes.

Authors:  Edwin J R van Beek
Journal:  Intern Emerg Med       Date:  2009-04-18       Impact factor: 3.397

Review 6.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

7.  Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients.

Authors:  Nunzia Tacelli; Martine Remy-Jardin; Thomas Flohr; Jean-Baptiste Faivre; Valérie Delannoy; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2009-11-05       Impact factor: 5.315

8.  Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

Authors:  D Ippolito; C Talei Franzesi; D Fior; P A Bonaffini; O Minutolo; S Sironi
Journal:  Br J Radiol       Date:  2015-03-18       Impact factor: 3.039

9.  Iterative reconstruction technique vs filter back projection: utility for quantitative bronchial assessment on low-dose thin-section MDCT in patients with/without chronic obstructive pulmonary disease.

Authors:  Hisanobu Koyama; Yoshiharu Ohno; Mizuho Nishio; Sumiaki Matsumoto; Naoki Sugihara; Takeshi Yoshikawa; Shinichiro Seki; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2014-05-17       Impact factor: 5.315

10.  Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection.

Authors:  Antonio Moscariello; Richard A P Takx; U Joseph Schoepf; Matthias Renker; Peter L Zwerner; Terrence X O'Brien; Thomas Allmendinger; Sebastian Vogt; Bernhard Schmidt; Giancarlo Savino; Christian Fink; Lorenzo Bonomo; Thomas Henzler
Journal:  Eur Radiol       Date:  2011-05-25       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.