Literature DB >> 19137311

Initial experience with a chest pain protocol using 320-slice volume MDCT.

Patrick A Hein1, Valentina C Romano, Alexander Lembcke, Juliane May, Patrik Rogalla.   

Abstract

We sought to determine the feasibility and image quality of 320-slice volume computed tomography (CT) angiography for the evaluation of patients with acute chest pain. Thirty consecutive patients (11 female, 19 male, mean age 63.2 +/- 14.2 years) with noncritical, acute chest pain underwent 320-slice CT using a protocol consisting of a nonspiral, nongated CT of the entire chest, followed by a nonspiral, electrocardiography-gated CT study of the heart. Data were acquired following a biphasic intravenous injection of 90 ml iodinated contrast agent. Vessel attenuation values of different thoracic vascular territories were recorded, and image quality scored on a five-point scale by two readers. Mean attenuation was 467 +/- 69 HU in the ascending aorta, 334 +/- 52 HU in the aortic arch, 455 +/- 71 HU in the descending aorta, 492 +/- 94 HU in the pulmonary trunk, and 416 +/- 63 HU and 436 +/- 62 HU in the right and left coronary artery, respectively. Radiation exposure estimates ranged between 7 and 14 mSv. The CT protocol investigated enabled imaging of the thoracic aorta, coronary and pulmonary arteries with an excellent diagnostic quality for chest pain triage in all patients. This result was achieved with less contrast material and reduced radiation exposure compared with previously investigated imaging protocols.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19137311     DOI: 10.1007/s00330-008-1255-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

Review 1.  Imaging of aortic dissection by helical computed tomography (CT).

Authors:  Serge Willoteaux; Christophe Lions; Virginia Gaxotte; Ziad Negaiwi; J P Beregi
Journal:  Eur Radiol       Date:  2004-08-05       Impact factor: 5.315

2.  Clinical potentials of the prototype 256-detector row CT-scanner.

Authors:  Shinichiro Mori; Masahiro Endo; Takayuki Obata; Kenya Murase; Hideaki Fujiwara; Kandatsu Susumu; Shuji Tanada
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

3.  ECG-gated 64-MDCT angiography in the differential diagnosis of acute chest pain.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Andreas Knez; Peter Boekstegers; Maximilian F Reiser; Christoph R Becker
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

4.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

5.  ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain.

Authors:  Diana Litmanovich; Diana Litmanovitch; Giulia A Zamboni; Thomas H Hauser; Pei-Jan P Lin; Melvin E Clouse; Vassilios Raptopoulos
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

Review 6.  Clinical validity of a negative computed tomography scan in patients with suspected pulmonary embolism: a systematic review.

Authors:  Rene Quiroz; Nils Kucher; Kelly H Zou; Florian Kipfmueller; Philip Costello; Samuel Z Goldhaber; U Joseph Schoepf
Journal:  JAMA       Date:  2005-04-27       Impact factor: 56.272

7.  Coronary multidetector computed tomography in the assessment of patients with acute chest pain.

Authors:  Udo Hoffmann; John T Nagurney; Fabian Moselewski; Antonio Pena; Maros Ferencik; Claudia U Chae; Ricardo C Cury; Javed Butler; Suhny Abbara; David F Brown; Alex Manini; John H Nichols; Stephan Achenbach; Thomas J Brady
Journal:  Circulation       Date:  2006-10-30       Impact factor: 29.690

Review 8.  Use of multislice CT for the evaluation of emergency room patients with chest pain: the so-called "triple rule-out".

Authors:  Michael J Gallagher; Gilbert L Raff
Journal:  Catheter Cardiovasc Interv       Date:  2008-01-01       Impact factor: 2.692

9.  Dual-source CT for chest pain assessment.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Alexander Becker; Alexander W Leber; Carsten Rist; Bernd J Wintersperger; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2007-11-22       Impact factor: 5.315

10.  Dual-source computed tomography in patients with acute chest pain: feasibility and image quality.

Authors:  Thomas Schertler; Hans Scheffel; Thomas Frauenfelder; Lotus Desbiolles; Sebastian Leschka; Paul Stolzmann; Burkhardt Seifert; Thomas G Flohr; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2007-09-13       Impact factor: 5.315

View more
  24 in total

1.  Automatic vs semi-automatic global cardiac function assessment using 64-row CT.

Authors:  J Greupner; E Zimmermann; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

Review 2.  Radiation dose reduction in CT coronary angiography.

Authors:  Brian P Shapiro; Phillip M Young; Birgit Kantor; Yeon Hyeon Choe; Cynthia H McCollough; Thomas C Gerber
Journal:  Curr Cardiol Rep       Date:  2010-01       Impact factor: 2.931

Review 3.  Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

Authors:  E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri
Journal:  Radiol Med       Date:  2010-06-23       Impact factor: 3.469

4.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

5.  Prognostic value of computed tomography coronary angiography in patients with chest pain of suspected cardiac origin.

Authors:  E Maffei; S Seitun; C Martini; A Aldrovandi; G Cervellin; C Tedeschi; A Guaricci; G Messalli; O Catalano; F Cademartiri
Journal:  Radiol Med       Date:  2011-03-07       Impact factor: 3.469

6.  Assessment of modified Blalock-Taussig shunt in children with congenital heart disease using multidetector-row computed tomography.

Authors:  Manal Mohamed Helmy Nabo; Yasunobu Hayabuchi; Miki Inoue; Noriko Watanabe; Miho Sakata; Shoji Kagami
Journal:  Heart Vessels       Date:  2010-09-28       Impact factor: 2.037

7.  Evaluation of swallowing using 320-detector-row multislice CT. Part I: single- and multiphase volume scanning for three-dimensional morphological and kinematic analysis.

Authors:  Naoko Fujii; Yoko Inamoto; Eiichi Saitoh; Mikoto Baba; Sumiko Okada; Satoshi Yoshioka; Toshiaki Nakai; Yoshihiro Ida; Kazuhiro Katada; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2010-01-20       Impact factor: 3.438

Review 8.  Cardiac CT in the emergency department: convincing evidence, but cautious implementation.

Authors:  Ricardo C Cury; Gudrun Feuchtner; Carol Mascioli; Jonathon Fialkow; Paul Andrulonis; Tomas Villanueva; Constantino S Pena; Warren R Janowitz; Barry T Katzen; Jack A Ziffer
Journal:  J Nucl Cardiol       Date:  2011-04       Impact factor: 5.952

9.  Radiation dose optimization for the bolus tracking technique in abdominal computed tomography: usefulness of real-time iterative reconstruction for monitoring scan.

Authors:  Yuya Ishikawa; Atsushi Urikura; Tsukasa Yoshida; Keisuke Takiguchi; Yoshihiro Nakaya
Journal:  Radiol Phys Technol       Date:  2016-09-30

10.  Diagnostic accuracy of 320-row computed tomography as compared with invasive coronary angiography in unselected, consecutive patients with suspected coronary artery disease.

Authors:  F Pelliccia; V Pasceri; A Evangelista; A Pergolini; F Barillà; N Viceconte; G Tanzilli; M Schiariti; C Greco; C Gaudio
Journal:  Int J Cardiovasc Imaging       Date:  2012-07-18       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.