Literature DB >> 17632730

Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography.

Gijs K A van Wermeskerken1, Mathias Prokop, Adriaan F van Olphen, Frans W J Albers.   

Abstract

The development of electrode arrays, the past years, has focused on modiolus-hugging cochlear implant electrodes. Besides, atraumatic implantation of electrodes is of importance for the use in hearing preservation, in cases of combined electric and acoustic stimulation. Intracochlear positioning of the individual electrodes by means of multislice computer tomography (CT) has not yet been shown. In this study we formulated and tested a CT imaging protocol for postoperative scanning of the temporal bone in cochlear implant subjects. Both a fresh human temporal bone and a fresh human cadaver head were implanted with a cochlear implant. Multislice CT was performed for adequate depiction of the cochlear implant. All scans were analyzed on a viewing workstation. After mid-modiolar reconstruction we were able to identify the intracochlear electrode position relative to the scala tympani and scala vestibuli. This was possible in both the implanted isolated temporal bone and the fresh human cadaver head. The feasibility of imaging the electrode position of the cochlear implant within the intracochlear spaces is shown with multislice CT. An imaging protocol is suggested.

Entities:  

Mesh:

Year:  2007        PMID: 17632730     DOI: 10.1007/s00405-007-0389-7

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  15 in total

1.  Subsecond multi-slice computed tomography: basics and applications.

Authors:  K Klingenbeck-Regn; S Schaller; T Flohr; B Ohnesorge; A F Kopp; U Baum
Journal:  Eur J Radiol       Date:  1999-08       Impact factor: 3.528

2.  Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays.

Authors:  M Tykocinski; L T Cohen; B C Pyman; T Roland; C Treaba; J Palamara; M C Dahm; R K Shepherd; J Xu; R S Cowan; N L Cohen; G M Clark
Journal:  Am J Otol       Date:  2000-03

3.  The Nucleus Contour electrode array: a radiological and histological study.

Authors:  B Richter; A Aschendorff; P Lohnstein; H Husstedt; H Nagursky; R Laszig
Journal:  Laryngoscope       Date:  2001-03       Impact factor: 3.325

4.  Cochlear structures after implantation of a perimodiolar electrode array.

Authors:  B Richter; K Jaekel; A Aschendorff; N Marangos; R Laszig
Journal:  Laryngoscope       Date:  2001-05       Impact factor: 3.325

5.  Factors predicting postoperative sentence scores in postlinguistically deaf adult cochlear implant patients.

Authors:  P J Blamey; B C Pyman; M Gordon; G M Clark; A M Brown; R C Dowell; R D Hollow
Journal:  Ann Otol Rhinol Laryngol       Date:  1992-04       Impact factor: 1.547

6.  The human spiral ganglion: new insights into ultrastructure, survival rate and implications for cochlear implants.

Authors:  Rudolf Glueckert; Kristian Pfaller; Anders Kinnefors; Helge Rask-Andersen; Anneliese Schrott-Fischer
Journal:  Audiol Neurootol       Date:  2005-05-27       Impact factor: 1.854

7.  Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation.

Authors:  R K Shepherd; S Hatsushika; G M Clark
Journal:  Hear Res       Date:  1993-03       Impact factor: 3.208

8.  CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in Nucleus-22 recipients.

Authors:  Margaret W Skinner; Darlene R Ketten; Laura K Holden; Gary W Harding; Peter G Smith; George A Gates; J Gail Neely; G Robert Kletzker; Barry Brunsden; Barbara Blocker
Journal:  J Assoc Res Otolaryngol       Date:  2002-02-27

9.  Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation.

Authors:  Oliver Adunka; Jan Kiefer; Marc H Unkelbach; Thomas Lehnert; Wolfgang Gstoettner
Journal:  Laryngoscope       Date:  2004-07       Impact factor: 3.325

10.  Imaging procedures in cochlear implant patients--evaluation of different radiological techniques.

Authors:  A Aschendorff; R Kubalek; A Hochmuth; A Bink; C Kurtz; P Lohnstein; T Klenzner; R Laszig
Journal:  Acta Otolaryngol Suppl       Date:  2004-05
View more
  8 in total

1.  [Intracochlear electrode position: evaluation after deep insertion using cone beam computed tomography].

Authors:  C Güldner; R Weiss; B Eivazi; S Bien; J A Werner; I Diogo
Journal:  HNO       Date:  2012-09       Impact factor: 1.284

2.  [Cochlear implants in isolated temporal bones: evaluation of electrode position with 64-slice computed tomography].

Authors:  J H Wagner; G Rademacher; A Ernst; I Todt
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

3.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

4.  On the accuracy of cochlear duct length measurement in computed tomographic images.

Authors:  G Jakob Lexow; Marcel Kluge; Nils-Claudius Gellrich; Thomas Lenarz; Omid Majdani; Thomas S Rau
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-03-12       Impact factor: 2.503

5.  Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomography.

Authors:  Theodore A Schuman; Jack H Noble; Charles G Wright; George B Wanna; Benoit Dawant; Robert F Labadie
Journal:  Laryngoscope       Date:  2010-11       Impact factor: 3.325

6.  MRI-Based Estimation of Scalar Cochlear-Implant Electrode Position.

Authors:  A Stratmann; P Mittmann; G Rademacher; G Grupe; S Hoffmann; S Mutze; A Ernst; I Todt
Journal:  Biomed Res Int       Date:  2017-10-17       Impact factor: 3.411

7.  Imaging of electrode position in relation to electrode functioning after cochlear implantation.

Authors:  Gijs K A van Wermeskerken; Adriaan F van Olphen; Kees Graamans
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-03-24       Impact factor: 2.503

8.  Imaging of Electrode Position after Cochlear Implantation with Flat Panel CT.

Authors:  Diana Arweiler-Harbeck; Christoph Mönninghoff; Jens Greve; Thomas Hoffmann; Sophia Göricke; Judith Arnolds; Nina Theysohn; Ulrich Gollner; Stephan Lang; Michael Forsting; Marc Schlamann
Journal:  ISRN Otolaryngol       Date:  2012-12-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.