Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.

Thomas Ho1, Arthur C K Cheng, Srinivas K Rao, Silvania Lau, Chris K S Leung, Dennis S C Lam.   

Abstract

PURPOSE: To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia.
SETTING: Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR.
METHODS: Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb), Visante (Carl Zeiss Meditec), Pentacam (Oculus, Inc.), and ultrasound (US) pachymetry (Sonomed, 200P) 6 months after surgery. Data were analyzed using the paired sample t test, Bland-Altman plots, and linear regression.
RESULTS: The mean postoperative pachymetry measured by US, Orbscan (0.89 acoustic factor), Pentacam, and Visante pachymetry were 438.2 microm+/-41.18 (SD), 435.17+/-49.63 microm, 430.66+/-40.23 microm, and 426.56+/-41.6 microm, respectively. Compared with the US measurement, Pentacam and Visante measurements significantly underestimated corneal thickness by a mean of 7.54+/-15.06 microm (P<.01) and 11.64+/-12.87 microm (P<.01), respectively. There was no statistically significant difference between US and Orbscan measurements.
CONCLUSION: Pentacam and Visante measurements of corneal thickness 6 months after LASIK were significantly less than those obtained using Orbscan and US pachymetry, although all 4 measurement methods showed a high correlation with each other.

Entities:  

Mesh:

Year:  2007        PMID: 17586372     DOI: 10.1016/j.jcrs.2007.03.028

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  25 in total

1.  Pachymetric mapping with Fourier-domain optical coherence tomography.

Authors:  Yan Li; Maolong Tang; Xinbo Zhang; Camila H Salaroli; Jose L Ramos; David Huang
Journal:  J Cataract Refract Surg       Date:  2010-05       Impact factor: 3.351

2.  Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry.

Authors:  Yong-Heng Luo; Qian Zhong; Ping-Bo Ouyang; Xiao-Jian Guo; Xuan-Chu Duan
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

3.  Central corneal thickness in southern Egypt.

Authors:  Engy Mohamed Mostafa
Journal:  Int Ophthalmol       Date:  2013-11-22       Impact factor: 2.031

4.  Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes.

Authors:  Wenjing Wu; Yan Wang; Lulu Xu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-12       Impact factor: 3.117

5.  Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery.

Authors:  Jumpei Matsuda; Osamu Hieda; Shigeru Kinoshita
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

6.  Repeatability and comparability of corneal thickness measurements obtained from Dual Scheimpflug Analyzer and from ultrasonic pachymetry.

Authors:  Zaina N Al-Mohtaseb; Li Wang; Mitchell P Weikert
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-02-17       Impact factor: 3.117

7.  [Influence of corneal biomechanical properties on myopic regression after laser in situ keratomileusis].

Authors:  D Uthoff; K Hebestedt; G I W Duncker; E Spörl
Journal:  Ophthalmologe       Date:  2013-01       Impact factor: 1.059

8.  Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry.

Authors:  Jeevan S Ladi; Nitant A Shah
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

9.  Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system.

Authors:  Jing Dong; Qiang Wu; Xiao-Gang Wang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

10.  Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation.

Authors:  Muriël Doors; Lars P J Cruysberg; Tos T J M Berendschot; John de Brabander; Frenne Verbakel; Carroll A B Webers; Rudy M M A Nuijts
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-04-30       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.