Literature DB >> 24195029

Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system.

Jing Dong1, Qiang Wu, Xiao-Gang Wang.   

Abstract

AIM: To measure central corneal thickness (CCT) and pre-corneal tear film thickness using the Galilei dual-Scheimpflug analyzer (GSA) in New Zealand white rabbits.
METHODS: Ten normal New Zealand white rabbits (20 eyes) were included in this study. With the assistance of 0.1% fluorescein, the pre-corneal tear film can be well visualized. Both eyes of each rabbit were scanned once with the GSA pre- and post-instillation of 1µL 0.1% fluorescein. The difference between the two measurements of CCT (4-mm diameter) was recorded as the pachymetric values of the central tear film.
RESULTS: The CCT of pre- and post-instillation was 388.8±9.5µm and 407.0±10.5µm, respectively. After a paired t-test analysis, the central pre-corneal tear film thickness of 4mm diameter was 18.2±5.31µm with a 95% confidence interval of (15.7, 20.6)µm (P<0.001).
CONCLUSION: GSA can be used to measure CCT and analyze central tear film thickness of rabbits with the help of fluorescein.

Entities:  

Keywords:  Scheimpflug; central corneal thickness; fluorescein; rabbits; tear film

Year:  2013        PMID: 24195029      PMCID: PMC3808901          DOI: 10.3980/j.issn.2222-3959.2013.05.05

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  32 in total

1.  The thickness of the human precorneal tear film: evidence from reflection spectra.

Authors:  P E King-Smith; B A Fink; N Fogt; K K Nichols; R M Hill; G S Wilson
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-10       Impact factor: 4.799

2.  Results of a dry eye questionnaire from optometric practices in North America.

Authors:  Carolyn G Begley; Barbara Caffery; Kelly Nichols; Gladys Lynn Mitchell; Robin Chalmers
Journal:  Adv Exp Med Biol       Date:  2002       Impact factor: 2.622

3.  Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

Authors:  Shiro Amano; Norihiko Honda; Yuki Amano; Satoru Yamagami; Takashi Miyai; Tomokazu Samejima; Miyuki Ogata; Kazunori Miyata
Journal:  Ophthalmology       Date:  2006-06       Impact factor: 12.079

4.  Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.

Authors:  Thomas Ho; Arthur C K Cheng; Srinivas K Rao; Silvania Lau; Chris K S Leung; Dennis S C Lam
Journal:  J Cataract Refract Surg       Date:  2007-07       Impact factor: 3.351

5.  Study of human precorneal tear film thickness and structure using laser interferometry.

Authors:  J I Prydal; P Artal; H Woon; F W Campbell
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-05       Impact factor: 4.799

6.  Implications of the effects of general anesthesia on basal tear production.

Authors:  D A Cross; T Krupin
Journal:  Anesth Analg       Date:  1977 Jan-Feb       Impact factor: 5.108

7.  Importance of the lipid layer in human tear film stability and evaporation.

Authors:  J P Craig; A Tomlinson
Journal:  Optom Vis Sci       Date:  1997-01       Impact factor: 1.973

8.  Tear film physiology.

Authors:  F J Holly
Journal:  Am J Optom Physiol Opt       Date:  1980-04

9.  Comparison of central corneal thickness measurements with the Galilei dual Scheimpflug analyzer and ultrasound pachymetry.

Authors:  Jeevan S Ladi; Nitant A Shah
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

10.  A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.

Authors:  Hong Zhuang; Xingtao Zhou; Jianjiang Xu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-08-26       Impact factor: 4.799

View more
  3 in total

1.  THz and mm-Wave Sensing of Corneal Tissue Water Content: Electromagnetic Modeling and Analysis.

Authors:  Zachary D Taylor; James Garritano; Shijun Sung; Neha Bajwa; David B Bennett; Bryan Nowroozi; Priyamvada Tewari; James Sayre; Jean-Pierre Hubschman; Sophie Deng; Elliott R Brown; Warren S Grundfest
Journal:  IEEE Trans Terahertz Sci Technol       Date:  2015-03       Impact factor: 3.274

2.  Topical Ocular Drug Delivery to the Back of the Eye by Mucus-Penetrating Particles.

Authors:  Lisa R Schopf; Alexey M Popov; Elizabeth M Enlow; James L Bourassa; Winston Z Ong; Pawel Nowak; Hongming Chen
Journal:  Transl Vis Sci Technol       Date:  2015-06-11       Impact factor: 3.283

3.  Protective Effects of Soluble Collagen during Ultraviolet-A Crosslinking on Enzyme-Mediated Corneal Ectatic Models.

Authors:  Xiaokun Wang; Yong Huang; Sabah Jastaneiah; Shoumyo Majumdar; Jin U Kang; Samuel C Yiu; Walter Stark; Jennifer H Elisseeff
Journal:  PLoS One       Date:  2015-09-01       Impact factor: 3.240

  3 in total