Literature DB >> 17557182

Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty.

Tsutomu Gomi1, Hiroshi Hirano.   

Abstract

The present study was performed to evaluate the potential for clinical application of digital linear tomosynthesis in imaging hip prostheses. Volumetric x-ray digital linear tomosysnthesis was used to image hip prostheses. The tomosynthesis was compared to metal artifact reduction (MAR) computed tomography (CT), and non-MAR CT scans of a prosthesis case. The effectiveness of this method in enhancing visibility of a prosthesis case was quantified in terms of the signal-to-noise ratio (SNR), and removal of ghosting artifacts in a prosthesis case was quantified in terms of the artifact spread function (ASF). In the near in-focus plane, the contrast is greater in the MAR CT or tomosynthesis relative to the non-MAR CT. The order of ASF performance of the algorithm was as follows: (1) tomosynthesis; (2) MAR-CT; (3) non-MAR CT. The potential usefulness of digital linear tomosynthesis for evaluation of hip prostheses was demonstrated. Further studies are required to determine the ability of digital linear tomosynthesis to quantify the spatial relationships between the metallic components of these devices as well as to identify bony changes with diagnostic consequences.

Entities:  

Mesh:

Year:  2008        PMID: 17557182      PMCID: PMC3043838          DOI: 10.1007/s10278-007-9040-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  25 in total

1.  Comparison of tomosynthesis methods used with digital mammography.

Authors:  S Suryanarayanan; A Karellas; S Vedantham; S J Glick; C J D'Orsi; S P Baker; R L Webber
Journal:  Acad Radiol       Date:  2000-12       Impact factor: 3.173

2.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction.

Authors: 
Journal:  Microsc Microanal       Date:  1999-01       Impact factor: 4.127

3.  Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner.

Authors:  EhabI M Kamel; Cyrill Burger; Alfred Buck; GustavI K von Schulthess; GerhardI W Goerres
Journal:  Eur Radiol       Date:  2002-08-23       Impact factor: 5.315

Review 4.  Digital x-ray tomosynthesis: current state of the art and clinical potential.

Authors:  James T Dobbins; Devon J Godfrey
Journal:  Phys Med Biol       Date:  2003-10-07       Impact factor: 3.609

5.  A comparison of reconstruction algorithms for breast tomosynthesis.

Authors:  Tao Wu; Richard H Moore; Elizabeth A Rafferty; Daniel B Kopans
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

6.  Restoration of digital multiplane tomosynthesis by a constrained iteration method.

Authors:  U E Ruttimann; R A Groenhuis; R L Webber
Journal:  IEEE Trans Med Imaging       Date:  1984       Impact factor: 10.048

7.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

8.  Digital tomosynthesis of hand joints for arthritis assessment.

Authors:  J Duryea; J T Dobbins; J A Lynch
Journal:  Med Phys       Date:  2003-03       Impact factor: 4.071

9.  Ectomography--a new radiographic reconstruction method--II. Computer simulated experiments.

Authors:  C U Petersson; P Edholm; G H Granlund; H E Knutsson
Journal:  IEEE Trans Biomed Eng       Date:  1980-11       Impact factor: 4.538

10.  Ectomography--a new radiographic reconstruction method--I. Theory and error estimates.

Authors:  H E Knutsson; P Edholm; G H Granlund; C U Petersson
Journal:  IEEE Trans Biomed Eng       Date:  1980-11       Impact factor: 4.538

View more
  13 in total

1.  Comparison between chest digital tomosynthesis and CT as a screening method to detect artificial pulmonary nodules: a phantom study.

Authors:  T Gomi; M Nakajima; H Fujiwara; T Takeda; K Saito; T Umeda; K Sakaguchi
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

2.  Technical innovation: digital tomosynthesis of the hip following intra-articular administration of contrast.

Authors:  Roland E Gazaille; Michael J Flynn; Walter Page; Sonia Finley; Marnix van Holsbeeck
Journal:  Skeletal Radiol       Date:  2011-08-07       Impact factor: 2.199

3.  Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array.

Authors:  J Shan; A W Tucker; L R Gaalaas; G Wu; E Platin; A Mol; J Lu; O Zhou
Journal:  Dentomaxillofac Radiol       Date:  2015-06-19       Impact factor: 2.419

4.  Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening.

Authors:  Romain Gillet; Pedro Teixeira; Chloé Bonarelli; Henry Coudane; François Sirveaux; Mathias Louis; Alain Blum
Journal:  Eur Radiol       Date:  2018-09-07       Impact factor: 5.315

5.  Comparison of Reconstruction Algorithms for Decreasing the Exposure Dose During Digital Tomosynthesis for Arthroplasty: a Phantom Study.

Authors:  Tsutomu Gomi; Rina Sakai; Masami Goto; Yusuke Watanabe; Tohoru Takeda; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2016-08       Impact factor: 4.056

6.  Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Authors:  Hao Tang; Dejin Yang; Shengjie Guo; Jing Tang; Jian Liu; Dacheng Wang; Yixin Zhou
Journal:  Skeletal Radiol       Date:  2016-09-02       Impact factor: 2.199

7.  Bone-to-bone integrations were complete within 5 months after anatomical rectangular tunnel anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft.

Authors:  Hironari Masuda; Shuji Taketomi; Hiroshi Inui; Naoya Shimazaki; Nobuhiro Nishihara; Seikai Toyooka; Hirotaka Kawano; Takumi Nakagawa
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-16       Impact factor: 4.342

8.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

9.  Assessment of lateral hindfoot impingement with weightbearing multiplanar imaging in a flatfoot.

Authors:  Yasuhisa Yoshida; Hidenori Matsubara; Hiroki Kawashima; Takao Aikawa; Shuhei Ugaji; Tomo Hamada; Hiroyuki Tsuchiya
Journal:  Acta Radiol Open       Date:  2020-07-31

10.  The utility of digital linear tomosynthesis imaging of total hip joint arthroplasty with suspicion of loosening: a prospective study in 40 patients.

Authors:  Jan H Göthlin; Mats Geijer
Journal:  Biomed Res Int       Date:  2013-09-03       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.