Literature DB >> 12664109

Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner.

EhabI M Kamel1, Cyrill Burger, Alfred Buck, GustavI K von Schulthess, GerhardI W Goerres.   

Abstract

Our objective was to study the effect of metal-induced artifacts on the accuracy of the CT-based anatomic map as a prerequisite for attenuation correction of the positron emission tomography (PET) emission data. Twenty-seven oncology patients with dental metalwork were enrolled in the present study. Data acquisition was performed on a PET/CT in-line system (Discovery LS, GE Medical Systems, Milwaukee, Wis.). Attenuation correction of emission data was done twice, using an 80-mA CT scan (PET(CT80)) and a (68)Ge transmission scan (PET(68Ge)). Average count in kBq/cc was measured in regions with and without artifacts and compared for PET(CT80) and PET(68Ge). Data analysis of region of interests (ROIs) revealed that the ratio (ROIs PET(CT80)/ROIs PET(68Ge)) and the difference (ROIs PET(CT80) minus ROIs PET(68Ge)) had a higher mean of values in regions with artifacts than in regions without artifacts (1.2+/-0.17 vs 1.06+/-0.06 and 0.68+/-0.67 vs 0.15+/-0.17 kBq/cc, respectively). For most of the studied artifactual ROIs, the PET(CT80) values were higher than those of the PET(68Ge). Attenuation correction of PET emission data using an artifactual CT map yields false values in regions nearby artifacts caused by dental metalwork. This may falsely estimate PET quantitative studies and may disturb the visual interpretation of PET scan.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12664109     DOI: 10.1007/s00330-002-1564-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  37 in total

Review 1.  PET/CT: a new imaging technology in nuclear medicine.

Authors:  Heiko Schöder; Yusuf E Erdi; Steven M Larson; Henry W D Yeung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-05       Impact factor: 9.236

2.  Side-by-side reading of PET and CT scans in oncology: which patients might profit from integrated PET/CT?

Authors:  Patrick Reinartz; Franz-Josef Wieres; Wolfram Schneider; Alexander Schur; Ulrich Buell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-10       Impact factor: 9.236

3.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images.

Authors:  Oliver Watzke; Willi A Kalender
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

4.  Calcified Lymph Nodes Causing Clinically Relevant Attenuation Correction Artifacts on PET/CT Imaging.

Authors:  Amar Mehta; Ajeet Mehta; Charles Laymon; Todd M Blodgett
Journal:  J Radiol Case Rep       Date:  2010-02-01

5.  Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

Authors:  D Prell; W A Kalender; Y Kyriakou
Journal:  Br J Radiol       Date:  2010-09-21       Impact factor: 3.039

6.  Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Authors:  Pardis Ghafarian; S M R Aghamiri; Mohammad R Ay; Arman Rahmim; Thomas H Schindler; Osman Ratib; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-10-20       Impact factor: 9.236

7.  Qualitative and quantitative assessment of metal artifacts arising from implantable cardiac pacing devices in oncological PET/CT studies: a phantom study.

Authors:  Mohammad R Ay; Abolfazl Mehranian; Mehrsima Abdoli; Pardis Ghafarian; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-12       Impact factor: 3.488

8.  Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI.

Authors:  Ryogo Minamimoto; Craig Levin; Mehran Jamali; Dawn Holley; Amir Barkhodari; Greg Zaharchuk; Andrei Iagaru
Journal:  Mol Imaging Biol       Date:  2016-10       Impact factor: 3.488

9.  Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI.

Authors:  C Buchbender; V Hartung-Knemeyer; M Forsting; G Antoch; T A Heusner
Journal:  Br J Radiol       Date:  2013-05       Impact factor: 3.039

10.  18F-FDG PET/CT evaluation of children and young adults with suspected spinal fusion hardware infection.

Authors:  Brian M Bagrosky; Kari L Hayes; Phillip J Koo; Laura Z Fenton
Journal:  Pediatr Radiol       Date:  2013-03-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.