Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Hao Tang1, Xingjian Huang1, Xiaoguang Cheng2, Dejin Yang1, Yong Huang1, Yixin Zhou1.   

Abstract

BACKGROUND: The traditional criterion for the diagnosis of implant loosening in total hip arthroplasty (THA) was once defined as a radiolucent line of >2 mm in width, based on plain radiography. Recent progress in imaging technology has allowed for the identification of complete radiolucent lines of ≤2 mm around the whole prosthesis as the basis for diagnosing component loosening in the absence of component migration. This study aimed to compare the sensitivity and specificity of digital tomosynthesis with metal artifact reduction with those of radiography and conventional computed tomography (CT) for detecting radiolucent lines of ≤2 mm surrounding cementless femoral stems of different widths.
METHODS: The medullary canals of 4 cadaveric femurs were broached to 13 mm in diameter. Cylindrical cementless femoral stems with diameters of 9, 10, 11, 12, and 13 mm were sequentially inserted into each femur, creating 5 groups of radiolucent lines 2.0, 1.5-1.6, 1.1-1.2, 0.5-0.6, and 0 mm in diameter, respectively. Imaging by tomosynthesis, radiography, and CT was conducted for each radiolucent line model. The width information of the radiolucent line models was used as a reference standard for calculating sensitivity and specificity: observations in the group of 0 mm were used for calculating specificity, and those in the other four groups were used for sensitivity. The differences in sensitivity and specificity between the imaging methods were compared with chi-square test, and the 95% confidence intervals of improvements in the sensitivity and specificity of tomosynthesis compared with radiography and CT were calculated using mixed effects models.
RESULTS: The overall sensitivity of tomosynthesis (63.3%) for detecting radiolucent lines ≤2 mm wide was significantly higher (P<0.017) than that of radiography (20.5%) and CT (50.2%), an improvement of 58.2%±3.1% (95% CI, P<0.001) and 21.7%±7.1% (95% CI, P<0.001) compared to radiography and CT, respectively. The sensitivity values for detecting radiolucent lines in all four groups by tomosynthesis and CT were significantly higher than those of radiography (P<0.017). Tomosynthesis also had significantly higher sensitivity than CT (P<0.017) in detecting radiolucent line ≤1.2 mm wide. The specificity of TMAR, radiography, and CT for detecting radiolucent lines was 87.5%, 92.5%, and 82.5%, respectively, with no significant difference (P>0.017).
CONCLUSIONS: Digital tomosynthesis with metal artifact reduction had significantly higher sensitivity than radiography for detecting radiolucent lines ≤2 mm wide surrounding cementless femoral stems. It also displayed higher sensitivity than CT for detecting radiolucent lines ≤1.2 mm in width. With a higher rate of detection for radiolucent lines narrower than 2 mm, tomosynthesis has the potential to improve the accuracy of early diagnosis of cementless THA stem loosening in clinical practice. 2020 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Hip arthroplasty; digital tomosynthesis; radiolucent line; sensitivity; specificity

Year:  2020        PMID: 32879857      PMCID: PMC7417763          DOI: 10.21037/qims-19-1018

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  37 in total

1.  The femur in revision total hip arthroplasty evaluation and classification.

Authors:  Craig J Della Valle; Wayne G Paprosky
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

2.  Detection of osteophytes and subchondral cysts in the knee with use of tomosynthesis.

Authors:  Daichi Hayashi; Li Xu; Frank W Roemer; David J Hunter; Ling Li; Avinash M Katur; Ali Guermazi
Journal:  Radiology       Date:  2012-04       Impact factor: 11.105

3.  Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning.

Authors:  Jodie A Christner; James M Kofler; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2010-04       Impact factor: 3.959

4.  Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty.

Authors:  Tsutomu Gomi; Hiroshi Hirano
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

5.  Digital tomosynthesis (DTS) for quantitative assessment of trabecular microstructure in human vertebral bone.

Authors:  Woong Kim; Daniel Oravec; Srikant Nekkanty; Janardhan Yerramshetty; Edward A Sander; George W Divine; Michael J Flynn; Yener N Yeni
Journal:  Med Eng Phys       Date:  2014-12-08       Impact factor: 2.242

6.  Dual-layer spectral computerized tomography for metal artifact reduction: small versus large orthopedic devices.

Authors:  Christos Kosmas; Mojgan Hojjati; Peter C Young; Aidin Abedi; Ali Gholamrezanezhad; Prabhakar Rajiah
Journal:  Skeletal Radiol       Date:  2019-06-01       Impact factor: 2.199

7.  Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Authors:  Hao Tang; Dejin Yang; Shengjie Guo; Jing Tang; Jian Liu; Dacheng Wang; Yixin Zhou
Journal:  Skeletal Radiol       Date:  2016-09-02       Impact factor: 2.199

8.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

9.  Tissue reactions to titanium endoprostheses. Autopsy studies in four cases.

Authors:  F Lintner; K Zweymüller; G Brand
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

10.  Dual-energy contrast-enhanced spectral mammography (CESM) for breast cancer screening.

Authors:  Vera Sorin; Miri Sklair-Levy
Journal:  Quant Imaging Med Surg       Date:  2019-11
View more
  1 in total

Review 1.  Imaging in Hip Arthroplasty Management Part 2: Postoperative Diagnostic Imaging Strategy.

Authors:  Charles Lombard; Pierre Gillet; Edouard Germain; Fatma Boubaker; Alain Blum; Pedro Augusto Gondim Teixeira; Romain Gillet
Journal:  J Clin Med       Date:  2022-07-29       Impact factor: 4.964

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.