Literature DB >> 27589968

Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients.

Hao Tang1, Dejin Yang1, Shengjie Guo1, Jing Tang1, Jian Liu1, Dacheng Wang1, Yixin Zhou2.   

Abstract

OBJECTIVES: For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components.
MATERIALS AND METHODS: We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria.
RESULTS: For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT.
CONCLUSIONS: By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. LEVEL OF EVIDENCE: Level II, diagnostic cohort study.

Entities:  

Keywords:  Cementless total hip arthroplasty; Diagnostic accuracy; Digital tomosynthesis; Fixation stability; Radiolucent line; Spot weld

Mesh:

Year:  2016        PMID: 27589968     DOI: 10.1007/s00256-016-2466-8

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  32 in total

1.  Hip painful prosthesis: surgical view.

Authors:  Antonio Spinarelli; Vittorio Patella; Vito Conserva; Giovanni Vicenti; Vito Pesce; Silvio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2011-05

2.  Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty.

Authors:  Tsutomu Gomi; Hiroshi Hirano
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

3.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

4.  Postoperative follow-up of olecranon fracture by digital tomosynthesis radiography.

Authors:  Haruhiko Machida; Toshiyuki Yuhara; John M Sabol; Mieko Tamura; Yutaka Shimada; Eiko Ueno
Journal:  Jpn J Radiol       Date:  2011-09-17       Impact factor: 2.374

5.  The value of contrast arthrography in assessing loosening of symptomatic uncemented total hip components.

Authors:  R L Barrack; M Tanzer; S V Kattapuram; W H Harris
Journal:  Skeletal Radiol       Date:  1994-01       Impact factor: 2.199

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Results of isolated femoral component revision with well-fixed acetabular implant retention.

Authors:  Kyung Soon Park; Taek Rim Yoon; Eun Kyoo Song; Keun Bae Lee
Journal:  J Arthroplasty       Date:  2010-02-26       Impact factor: 4.757

8.  Clinical and radiographic evaluation of long-stem femoral components following revision total hip arthroplasty.

Authors:  J B Meding; M A Ritter; E M Keating; P M Faris
Journal:  J Arthroplasty       Date:  1994-08       Impact factor: 4.757

9.  Comparative study of DTS and CT in the skeletal trauma imaging diagnosis evaluation and radiation dose.

Authors:  Wei Xia; Xiao-rui Yin; Jing-Tao Wu; Hai-tao Wu
Journal:  Eur J Radiol       Date:  2012-10-15       Impact factor: 3.528

10.  Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty.

Authors:  Alejandro González Della Valle; Adriana Zoppi; Margaret G E Peterson; Eduardo A Salvati
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

View more
  8 in total

Review 1.  Skeletal Radiology: the year in review 2016.

Authors:  Daniel I Rosenthal; Mark Kransdorf; Gunnar Astrom
Journal:  Skeletal Radiol       Date:  2016-12-23       Impact factor: 2.199

2.  Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening.

Authors:  Romain Gillet; Pedro Teixeira; Chloé Bonarelli; Henry Coudane; François Sirveaux; Mathias Louis; Alain Blum
Journal:  Eur Radiol       Date:  2018-09-07       Impact factor: 5.315

3.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

4.  A Novel Quantitative Evaluation of Bone Formation After Opening Wedge High Tibial Osteotomy Using Tomosynthesis.

Authors:  Kyota Ishibashi; Eiji Sasaki; Edward Wijaya; Shohei Yamauchi; Shizuka Sasaki; Yuka Kimura; Yuji Yamamoto; Takashi Shimbo; Katsuto Tamai; Yasuyuki Ishibashi
Journal:  J Digit Imaging       Date:  2022-04-13       Impact factor: 4.903

5.  Diagnosis of and Early Revision Surgery for Biological Fixation Failure Due to Proximal-Distal Mismatch of Proximally Coated Tapered Cementless Stem.

Authors:  Yasuhiro Homma; So Kawakita; Tomonori Baba; Taiji Watari; Kazuo Kaneko
Journal:  Arthroplast Today       Date:  2020-11-04

6.  Development of a denoising convolutional neural network-based algorithm for metal artifact reduction in digital tomosynthesis for arthroplasty: A phantom study.

Authors:  Tsutomu Gomi; Rina Sakai; Hidetake Hara; Yusuke Watanabe; Shinya Mizukami
Journal:  PLoS One       Date:  2019-09-13       Impact factor: 3.240

7.  Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.

Authors:  Kazuki Oishi; Yuji Yamamoto; Yoshifumi Harada; Ryo Inoue; Eiji Sasaki; Yasuyuki Ishibashi
Journal:  J Orthop Surg Res       Date:  2021-04-15       Impact factor: 2.359

8.  Emphasizing the Diagnostic Value of Digital Tomosynthesis in Detecting Hip Fractures.

Authors:  Cory Ozimok; David Koff; Naveen Parasu
Journal:  Tomography       Date:  2020-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.