Literature DB >> 17433742

Simultaneous acquisition of magnetic resonance spectroscopy (MRS) data and positron emission tomography (PET) images with a prototype MR-compatible, small animal PET imager.

Raymond R Raylman1, Stan Majewski, S Sendhil Velan, Susan Lemieux, Brian Kross, Vladimir Popov, Mark F Smith, Andrew G Weisenberger.   

Abstract

Multi-modality imaging (such as PET-CT) is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET, fused with anatomical images created by MRI, allow the correlation of form with function. Perhaps more exciting than the combination of anatomical MRI with PET, is the melding of PET with MR spectroscopy (MRS). Thus, two aspects of physiology could be combined in novel ways to produce new insights into the physiology of normal and pathological processes. Our team is developing a system to acquire MRI images and MRS spectra, and PET images contemporaneously. The prototype MR-compatible PET system consists of two opposed detector heads (appropriate in size for small animal imaging), operating in coincidence mode with an active field-of-view of approximately 14 cm in diameter. Each detector consists of an array of LSO detector elements coupled through a 2-m long fiber optic light guide to a single position-sensitive photomultiplier tube. The use of light guides allows these magnetic field-sensitive elements of the PET imager to be positioned outside the strong magnetic field of our 3T MRI scanner. The PET scanner imager was integrated with a 12-cm diameter, 12-leg custom, birdcage coil. Simultaneous MRS spectra and PET images were successfully acquired from a multi-modality phantom consisting of a sphere filled with 17 brain relevant substances and a positron-emitting radionuclide. There were no significant changes in MRI or PET scanner performance when both were present in the MRI magnet bore. This successful initial test demonstrates the potential for using such a multi-modality to obtain complementary MRS and PET data.

Entities:  

Mesh:

Year:  2007        PMID: 17433742      PMCID: PMC1950253          DOI: 10.1016/j.jmr.2007.03.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  13 in total

1.  Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations.

Authors:  Mark F Smith; Raymond R Raylman; Stan Majewski; Andrew G Weisenberger
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

2.  Localized two-dimensional shift correlated MR spectroscopy of human brain.

Authors:  M A Thomas; K Yue; N Binesh; P Davanzo; A Kumar; B Siegel; M Frye; J Curran; R Lufkin; P Martin; B Guze
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

3.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

4.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

5.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].

Authors:  J Pauly; P Le Roux; D Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts.

Authors:  P B Garlick; P K Marsden; A C Cave; H G Parkes; R Slates; Y Shao; R W Silverman; S R Cherry
Journal:  NMR Biomed       Date:  1997-05       Impact factor: 4.044

7.  Proton spectroscopy of human brain with very short echo time using high gradient amplitudes.

Authors:  U Seeger; U Klose; D Seitz; T Nägele; O Lutz; W Grodd
Journal:  Magn Reson Imaging       Date:  1998       Impact factor: 2.546

8.  Simultaneous MRI and PET imaging of a rat brain.

Authors:  Raymond R Raylman; Stan Majewski; Susan K Lemieux; S Sendhil Velan; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger; Carl Zorn; Gary D Marano
Journal:  Phys Med Biol       Date:  2006-11-23       Impact factor: 3.609

9.  Investigation of muscle lipid metabolism by localized one- and two-dimensional MRS techniques using a clinical 3T MRI/MRS scanner.

Authors:  S Sendhil Velan; Christopher Durst; Susan K Lemieux; Raymond R Raylman; Rajagopalan Sridhar; Richard G Spencer; Gerald R Hobbs; M Albert Thomas
Journal:  J Magn Reson Imaging       Date:  2007-01       Impact factor: 4.813

10.  Estimation of metabolite concentrations from localized in vivo proton NMR spectra.

Authors:  S W Provencher
Journal:  Magn Reson Med       Date:  1993-12       Impact factor: 4.668

View more
  11 in total

1.  MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

Authors:  Ciprian Catana; Thomas Benner; Andre van der Kouwe; Larry Byars; Michael Hamm; Daniel B Chonde; Christian J Michel; Georges El Fakhri; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2011-01       Impact factor: 10.057

Review 2.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 3.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

4.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

5.  Technical performance evaluation of a human brain PET/MRI system.

Authors:  Armin Kolb; Hans F Wehrl; Matthias Hofmann; Martin S Judenhofer; Lars Eriksson; Ralf Ladebeck; Matthias P Lichy; Larry Byars; Christian Michel; Heinz-Peter Schlemmer; Matthias Schmand; Claus D Claussen; Vesna Sossi; Bernd J Pichler
Journal:  Eur Radiol       Date:  2012-03-27       Impact factor: 5.315

Review 6.  Principles of Simultaneous PET/MR Imaging.

Authors:  Ciprian Catana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-05       Impact factor: 2.266

Review 7.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

8.  Segmentation and characterization of interscapular brown adipose tissue in rats by multi-parametric magnetic resonance imaging.

Authors:  K N Bhanu Prakash; Sanjay K Verma; Jadegoud Yaligar; Julian Goggi; Venkatesh Gopalan; Swee Shean Lee; Xianfeng Tian; Shigeki Sugii; Melvin Khee Shing Leow; Kishore Bhakoo; Sendhil S Velan
Journal:  MAGMA       Date:  2016-01-08       Impact factor: 2.310

9.  In vivo functional and anatomic imaging for assessment of in vivo gene transfer.

Authors:  Sheela P Singh; Dan Yang; Murali Ravoori; Lin Han; Vikas Kundra
Journal:  Radiology       Date:  2009-07-08       Impact factor: 11.105

Review 10.  An integrated MR/PET system: prospective applications.

Authors:  Heinz-Peter Schlemmer; Bernd J Pichler; Robert Krieg; Wolf-Dieter Heiss
Journal:  Abdom Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.