Literature DB >> 18695301

Recent developments in PET detector technology.

Tom K Lewellen1.   

Abstract

Positron emission tomography (PET) is a tool for metabolic imaging that has been utilized since the earliest days of nuclear medicine. A key component of such imaging systems is the detector modules--an area of research and development with a long, rich history. Development of detectors for PET has often seen the migration of technologies, originally developed for high energy physics experiments, into prototype PET detectors. Of the many areas explored, some detector designs go on to be incorporated into prototype scanner systems and a few of these may go on to be seen in commercial scanners. There has been a steady, often very diverse development of prototype detectors, and the pace has accelerated with the increased use of PET in clinical studies (currently driven by PET/CT scanners) and the rapid proliferation of pre-clinical PET scanners for academic and commercial research applications. Most of these efforts are focused on scintillator-based detectors, although various alternatives continue to be considered. For example, wire chambers have been investigated many times over the years and more recently various solid-state devices have appeared in PET detector designs for very high spatial resolution applications. But even with scintillators, there have been a wide variety of designs and solutions investigated as developers search for solutions that offer very high spatial resolution, fast timing, high sensitivity and are yet cost effective. In this review, we will explore some of the recent developments in the quest for better PET detector technology.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18695301      PMCID: PMC2891023          DOI: 10.1088/0031-9155/53/17/R01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements.

Authors:  Stephen McCallum; Peter Clowes; Andrew Welch
Journal:  Phys Med Biol       Date:  2005-08-24       Impact factor: 3.609

2.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

3.  Depth of interaction decoding of a continuous crystal detector module.

Authors:  T Ling; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2007-03-29       Impact factor: 3.609

4.  Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depth-encoding PET detector.

Authors:  Huini Du; Yongfeng Yang; Simon R Cherry
Journal:  Phys Med Biol       Date:  2007-04-10       Impact factor: 3.609

Review 5.  Wire chambers revisited.

Authors:  R J Ott
Journal:  Eur J Nucl Med       Date:  1993-04

6.  Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations.

Authors:  Tomoyuki Hasegawa; Eiji Yoshida; Ayako Kobayashi; Kengo Shibuya; Fumihiko Nishikido; Tetsuya Kobayashi; Mikio Suga; Taiga Yamaya; Keishi Kitamura; Koichi Maruyama; Hideo Murayama
Journal:  Phys Med Biol       Date:  2006-12-18       Impact factor: 3.609

7.  Imaging characteristics of a 3-dimensional GSO whole-body PET camera.

Authors:  Suleman Surti; Joel S Karp
Journal:  J Nucl Med       Date:  2004-06       Impact factor: 10.057

8.  Impact of high energy resolution detectors on the performance of a PET system dedicated to breast cancer imaging.

Authors:  Craig S Levin; Angela M K Foudray; Frezghi Habte
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

9.  Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Richard Freifelder; Christopher A Cardi; Lars-Eric Adam; Kilian Bilger; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2003-08       Impact factor: 10.057

10.  Development of a BaF2/TMAE PET system.

Authors:  C W van Eijk; R W Hollander; B Fischer; K J Leliveld
Journal:  Med Prog Technol       Date:  1991
View more
  39 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

Review 2.  Promising new photon detection concepts for high-resolution clinical and preclinical PET.

Authors:  Craig S Levin
Journal:  J Nucl Med       Date:  2012-02       Impact factor: 10.057

3.  The engagement of FDG PET/CT image quality and harmonized quantification: from competitive to complementary.

Authors:  Ronald Boellaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-01       Impact factor: 9.236

Review 4.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

Review 5.  Focus on time-of-flight PET: the benefits of improved time resolution.

Authors:  Maurizio Conti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-13       Impact factor: 9.236

6.  A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

Authors:  H Kim; C-T Chen; N Eclov; A Ronzhin; P Murat; E Ramberg; S Los; Alice M Wyrwicz; Limin Li; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-06-01       Impact factor: 1.455

7.  Optimizing light transport in scintillation crystals for time-of-flight PET: an experimental and optical Monte Carlo simulation study.

Authors:  Eric Berg; Emilie Roncali; Simon R Cherry
Journal:  Biomed Opt Express       Date:  2015-05-26       Impact factor: 3.732

Review 8.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

9.  Fast gamma-ray interaction-position estimation using k-d tree search.

Authors:  Xin Li; Li Tao; Craig S Levin; Lars R Furenlid
Journal:  Phys Med Biol       Date:  2019-08-07       Impact factor: 3.609

10.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.