Literature DB >> 9408923

PET and NMR dual acquisition (PANDA): applications to isolated, perfused rat hearts.

P B Garlick1, P K Marsden, A C Cave, H G Parkes, R Slates, Y Shao, R W Silverman, S R Cherry.   

Abstract

Positron emission tomography and nuclear magnetic resonance spectroscopy are non-invasive techniques that allow serial metabolic measurements to be obtained in a single subject. Significant advantages could be obtained if both types of scans could be acquired with a single machine. A small-scale PET scanner, designed to operate in a high magnetic field, was therefore constructed and inserted into the top half of a 7.3 cm bore, 9.4 T NMR magnet and its performance characterized. The magnetic field did not significantly affect either the sensitivity (approximately 3 kcps/MBq) or the spatial resolution (2.0 mm full width at half maximum, measured using a 0.25 mm diameter line source) of the scanner. However, the presence of the PET scanner resulted in a small decrease in field homogeneity. The first, simultaneous 31P NMR spectra (200, 80 degrees pulses collected at 6 s intervals) and PET images (transverse, mid-ventricular slices at the level of the mitral value) from isolated, perfused rat hearts were acquired using a specially designed NMR probe inserted into the bottom half of the magnet. The PET images were of excellent quality, enabling the left ventricular wall and interventricular septum to be clearly seen. In conclusion, we have demonstrated the simultaneous acquisition of PET and NMR data from perfused rat hearts; we believe that the combination of these two powerful techniques has tremendous potential in both the laboratory and the clinic.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9408923     DOI: 10.1002/(sici)1099-1492(199705)10:3<138::aid-nbm474>3.0.co;2-h

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  13 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

Review 2.  Preclinical imaging of mammary intraepithelial neoplasia with positron emission tomography.

Authors:  Craig K Abbey; Alexander D Borowsky; Jeffery P Gregg; Robert D Cardiff; Simon R Cherry
Journal:  J Mammary Gland Biol Neoplasia       Date:  2006-04       Impact factor: 2.673

3.  Simultaneous acquisition of magnetic resonance spectroscopy (MRS) data and positron emission tomography (PET) images with a prototype MR-compatible, small animal PET imager.

Authors:  Raymond R Raylman; Stan Majewski; S Sendhil Velan; Susan Lemieux; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger
Journal:  J Magn Reson       Date:  2007-03-24       Impact factor: 2.229

Review 4.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

Review 5.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

6.  Effects of MR surface coils on PET quantification.

Authors:  Lawrence R MacDonald; Steve Kohlmyer; Chi Liu; Thomas K Lewellen; Paul E Kinahan
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

Review 7.  Clinical pediatric positron emission tomography/magnetic resonance program: a guide to successful implementation.

Authors:  Sandra Saade-Lemus; Elad Nevo; Iman Soliman; Hansel J Otero; Ralph W Magee; Elizabeth T Drum; Lisa J States
Journal:  Pediatr Radiol       Date:  2020-02-19

Review 8.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

9.  In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal-resolution beta +-sensitive microprobe.

Authors:  Frédéric Pain; Laurent Besret; Francoise Vaufrey; Marie-Claude Grégoire; Laurent Pinot; Philippe Gervais; Lydie Ploux; Gilles Bloch; Roland Mastrippolito; Philippe Lanièce; Philippe Hantraye
Journal:  Proc Natl Acad Sci U S A       Date:  2002-07-22       Impact factor: 11.205

10.  Organomatics and organometrics: Novel platforms for long-term whole-organ culture.

Authors:  Bote G Bruinsma; Martin L Yarmush; Korkut Uygun
Journal:  Technology (Singap World Sci)       Date:  2014-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.