Literature DB >> 15248588

Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations.

Mark F Smith1, Raymond R Raylman, Stan Majewski, Andrew G Weisenberger.   

Abstract

Positron emission mammography (PEM) with tomographic acquisition using dual planar detectors rotating about the breast can obtain complete angular sampling and has the potential to improve activity estimation compared with PEM using stationary detectors. PEM tomography (PEMT) was compared with stationary PEM for point source and compressed breast phantom studies performed with a compact dual detector system. The acquisition geometries were appropriate for the target application of PEM guidance of stereotactic core biopsy. Images were reconstructed with a three-dimensional iterative maximum likelihood expectation maximization algorithm. PEMT eliminated blurring normal to the detectors seen with stationary PEM. Depth of interaction effects distorted the shape of the point spread functions for PEMT as the angular range from normal incidence of lines of response used in image reconstruction increased. Streak artefacts in PEMT for large detector rotation increments led to the development of an expression for the maximum rotation increment that maintains complete angular sampling. Studies with a compressed breast phantom were used to investigate contrast and signal-to-noise ratio (SNR) trade-offs for different sized spherical tumour models. PEMT and PEM both had advantages depending on lesion size and detector separation. The most appropriate acquisition method for specific detection or quantitation tasks requires additional investigation.

Entities:  

Mesh:

Year:  2004        PMID: 15248588     DOI: 10.1088/0031-9155/49/11/022

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Effects of multiple-interaction photon events in a high-resolution PET system that uses 3-D positioning detectors.

Authors:  Yi Gu; Guillem Pratx; Frances W Y Lau; Craig S Levin
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Simultaneous acquisition of magnetic resonance spectroscopy (MRS) data and positron emission tomography (PET) images with a prototype MR-compatible, small animal PET imager.

Authors:  Raymond R Raylman; Stan Majewski; S Sendhil Velan; Susan Lemieux; Brian Kross; Vladimir Popov; Mark F Smith; Andrew G Weisenberger
Journal:  J Magn Reson       Date:  2007-03-24       Impact factor: 2.229

3.  Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance.

Authors:  Raymond R Raylman; Patrick Ledden; Alexander V Stolin; Bob Hou; Ganghadar Jaliparthi; Peter F Martone
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-08

Review 4.  Nuclear imaging of the breast: translating achievements in instrumentation into clinical use.

Authors:  Carrie B Hruska; Michael K O'Connor
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  Design study of a dedicated head and neck cancer PET system.

Authors:  Mohan Li; Brett Yockey; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-01-08

6.  A combined positron emission tomography (PET)-electron paramagnetic resonance imaging (EPRI) system: initial evaluation of a prototype scanner.

Authors:  Mark Tseytlin; Alexander V Stolin; Priyaankadevi Guggilapu; Andrey A Bobko; Valery V Khramtsov; Oxana Tseytlin; Raymond R Raylman
Journal:  Phys Med Biol       Date:  2018-05-16       Impact factor: 3.609

7.  A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

Authors:  Raymond R Raylman; Will Van Kampen; Alexander V Stolin; Wenbo Gong; Gangadhar Jaliparthi; Peter F Martone; Mark F Smith; David Sarment; Neal H Clinthorne; Mark Perna
Journal:  Med Phys       Date:  2018-02-23       Impact factor: 4.071

8.  TandemPET- A High Resolution, Small Animal, Virtual Pinhole-Based PET Scanner: Initial Design Study.

Authors:  Raymond R Raylman; Alexander V Stolin; Peter F Martone; Mark F Smith
Journal:  IEEE Trans Nucl Sci       Date:  2015-10-29       Impact factor: 1.679

9.  Molecular breast imaging: use of a dual-head dedicated gamma camera to detect small breast tumors.

Authors:  Carrie B Hruska; Stephen W Phillips; Dana H Whaley; Deborah J Rhodes; Michael K O'Connor
Journal:  AJR Am J Roentgenol       Date:  2008-12       Impact factor: 3.959

10.  Concept of an upright wearable positron emission tomography imager in humans.

Authors:  Christopher E Bauer; Julie Brefczynski-Lewis; Gary Marano; Mary-Beth Mandich; Alexander Stolin; Peter Martone; James W Lewis; Gangadhar Jaliparthi; Raymond R Raylman; Stan Majewski
Journal:  Brain Behav       Date:  2016-08-05       Impact factor: 2.708

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.