Literature DB >> 18222800

Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging].

J Pauly1, P Le Roux, D Nishimura, A Macovski.   

Abstract

An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the pulse performance. Several examples are presented to illustrate the more important tradeoffs. These include linear-phase and minimum- and maximum-phase pulses. Linear-phase pulses can be refocused with a gradient reversal and can be used as spin-echo pulses. Minimum- and maximum-phase pulses have better slice profiles, but cannot be completely refocused.

Year:  1991        PMID: 18222800     DOI: 10.1109/42.75611

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  200 in total

1.  Three-dimensional proton MR spectroscopic imaging of premature and term neonates.

Authors:  D B Vigneron; A J Barkovich; S M Noworolski; M von dem Bussche; R G Henry; Y Lu; J C Partridge; G Gregory; D M Ferriero
Journal:  AJNR Am J Neuroradiol       Date:  2001-08       Impact factor: 3.825

Review 2.  Three-dimensional magnetic resonance spectroscopic imaging of brain and prostate cancer.

Authors:  J Kurhanewicz; D B Vigneron; S J Nelson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

3.  Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Authors:  Cheng Li; Jeremy F Magland; Hamidreza Saligheh Rad; Hee Kwon Song; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

4.  Multislice ¹H MRSI of the human brain at 7 T using dynamic B₀ and B₁ shimming.

Authors:  Vincent O Boer; Dennis W J Klomp; Christoph Juchem; Peter R Luijten; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

Review 5.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

6.  Transmit/receive headcoil for optimal 1H MR spectroscopy of the brain in paediatric patients at 3T.

Authors:  D W J Klomp; M van der Graaf; M A A P Willemsen; Y M van der Meulen; A P M Kentgens; A Heerschap
Journal:  MAGMA       Date:  2004-05-24       Impact factor: 2.310

7.  Self-refocused adiabatic pulse for spin echo imaging at 7 T.

Authors:  Priti Balchandani; Mohammad Mehdi Khalighi; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

8.  Biochemical abnormalities of the medial temporal lobe and medial prefrontal cortex in late-life depression.

Authors:  Talaignair N Venkatraman; Ranga R Krishnan; David C Steffens; Allen W Song; Warren D Taylor
Journal:  Psychiatry Res       Date:  2009-04-30       Impact factor: 3.222

9.  Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage.

Authors:  Cornelius Eichner; Kourosh Jafari-Khouzani; Stephen Cauley; Himanshu Bhat; Pavlina Polaskova; Ovidiu C Andronesi; Otto Rapalino; Robert Turner; Lawrence L Wald; Steven Stufflebeam; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2013-10-28       Impact factor: 4.668

10.  Using bidirectional chemical exchange for improved hyperpolarized [13 C]bicarbonate pH imaging.

Authors:  David E Korenchan; Jeremy W Gordon; Sukumar Subramaniam; Renuka Sriram; Celine Baligand; Mark VanCriekinge; Robert Bok; Daniel B Vigneron; David M Wilson; Peder E Z Larson; John Kurhanewicz; Robert R Flavell
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.