Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.

Bart D Lynch1, Jakub Kozelka, Manisha K Ranade, Jonathan G Li, William E Simon, James F Dempsey.   

Abstract

In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression 1680 CCD array scanner, and a Microtek ScanMaker i900 CCD array scanner. For the two scanners we assessed the variation in optical density (OD) of GAFCHROMIC EBT film with scanning bed position, angular rotation of the film with respect to the scan line direction, and temperature inside the scanner due to repeated scanning. Scanning uniform radiochromic films demonstrated a distinct bowing effect in profiles in the direction of the CCD array with a nonuniformity of up to 17%. Profiles along a direction orthogonal to the CCD array demonstrated a 7% variation. A strong angular dependence was found in measurements made with the flatbed scanners; the effect could not be reproduced with the spot densitometer. An IMRT quality assurance film was scanned twice rotating the film 90' between the scans. For films scanned on the Epson scanner, up to 12% variation was observed in unirradiated EBT films rotated between 0 degrees and 90 degrees, which decreased to approximately 8% for EBT films irradiated to 300 cGy. Variations of up to 80% were observed for films scanned with the Microtek scanner. The scanners were found to significantly increase the film temperature with repeated scanning. Film temperature between 18 and 33 degrees C caused OD changes of approximately 7%. Considering these effects, we recommend adherence to a strict scanning protocol that includes: maintaining the orientation of films scanned on flatbed scanners, limiting scanning to the central portion of the scanner bed, and limiting the number of consecutive scans to minimize changes in OD caused by film heating.

Entities:  

Mesh:

Year:  2006        PMID: 17278806     DOI: 10.1118/1.2370505

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  45 in total

1.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.

Authors:  Alexandra Rink; David F Lewis; Sangya Varma; I Alex Vitkin; David A Jaffray
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Energy dependence of radiochromic dosimetry films for use in radiotherapy verification.

Authors:  Krzysztof Chełmiński; Wojciech Bulski; Dietmar Georg; Dominika Bodzak; Zbigniew Maniakowski; Dominika Oborska; Joanna Rostkowska; Małgorzata Kania
Journal:  Rep Pract Oncol Radiother       Date:  2010-03-30

4.  Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.

Authors:  Bradley P McCabe; Michael A Speidel; Tina L Pike; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Investigation into the feasibility of using PRESAGE/optical-CT dosimetry for the verification of gating treatments.

Authors:  Samuel L Brady; William E Brown; Corey G Clift; Sua Yoo; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-03-26       Impact factor: 3.609

6.  The role of oxygen in the photostimulation luminescence process of europium doped potassium chloride.

Authors:  Zhiyan Xiao; Thomas R Mazur; Joseph P Driewer; H Harold Li
Journal:  Radiat Meas       Date:  2015-05-01       Impact factor: 1.898

7.  Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools.

Authors:  Samuel L Brady; Greta Toncheva; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

8.  Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

Authors:  H Harold Li; Joseph P Driewer; Zhaohui Han; Daniel A Low; Deshan Yang; Zhiyan Xiao
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

9.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

10.  Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.

Authors:  David F Lewis; Maria F Chan
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.