Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.

Alexandra Rink1, David F Lewis, Sangya Varma, I Alex Vitkin, David A Jaffray.   

Abstract

The effects of temperature on real time changes in optical density (DeltaOD) of GAFCHROMIC EBT film were investigated. The spectral peak of maximum change in absorbance (lambdamax) was shown to downshift linearly when the temperature of the film was increased from 22 to 38 degrees C. The DeltaOD values were also shown to decrease linearly with temperature, and this decrease could not be attributed to the shift in lambdamax. A compensation scheme using lambdamax and a temperature-dependent correction factor was investigated, but provided limited improvement. Part of the reason may be the fluctuations in hydration of the active component, which were found to affect both position of absorbance peaks and the sensitivity of the film. To test the effect of hydration, laminated and unlaminated films were desiccated. This shifted both the major and minor absorbance peaks in the opposite direction to the change observed with temperature. The desiccated film also exhibited reduced sensitivity to ionizing radiation. Rehydration of the desiccated films did not reverse the effects, but rather gave rise to another form of the polymer with absorbance maxima upshifted further 20 nm. Hence, the spectral characteristics and sensitivity of the film can be dependent on its history, potentially complicating both real-time and conventional radiation dosimetry.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18975701      PMCID: PMC2736758          DOI: 10.1118/1.2975483

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  High-resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3T.

Authors:  A Berg; A Ertl; E Moser
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

2.  High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields.

Authors:  Andreas Mack; Günther Mack; Dirk Weltz; Stefan G Scheib; Heinz D Böttcher; Volker Seifert
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

3.  Optical-CT gel-dosimetry I: basic investigations.

Authors:  Mark Oldham; Jeffrey H Siewerdsen; Sai Kumar; John Wong; David A Jaffray
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

4.  Verification of Ir-192 near source dosimetry using GAFCHROMIC film.

Authors:  Sou-Tung Chiu-Tsao; Tamara L Duckworth; Neil S Patel; Julianna Pisch; Louis B Harrison
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

5.  Intra-irradiation changes in the signal of polymer-based dosimeter (GAFCHROMIC EBT) due to dose rate variations.

Authors:  Alexandra Rink; I Alex Vitkin; David A Jaffray
Journal:  Phys Med Biol       Date:  2007-10-26       Impact factor: 3.609

6.  Dependence of radiochromic film optical density post-exposure kinetics on dose and dose fractionation.

Authors:  I Ali; C Costescu; M Vicic; J F Dempsey; J F Williamson
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

7.  Radiation therapy dosimetry using magnetic resonance imaging of polymer gels.

Authors:  M J Maryanski; G S Ibbott; P Eastman; R J Schulz; J C Gore
Journal:  Med Phys       Date:  1996-05       Impact factor: 4.071

8.  GafChromic MD-55: investigated as a precision dosimeter.

Authors:  N V Klassen; L van der Zwan; J Cygler
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

9.  Predicting optical densitometer response as a function of light source characteristics for radiochromic film dosimetry.

Authors:  L E Reinstein; G R Gluckman; H I Amols
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

10.  Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

Authors:  D A Low; J F Dempsey; R Venkatesan; S Mutic; J Markman; E Mark Haacke; J A Purdy
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

View more
  11 in total

1.  Energy dependence of radiochromic dosimetry films for use in radiotherapy verification.

Authors:  Krzysztof Chełmiński; Wojciech Bulski; Dietmar Georg; Dominika Bodzak; Zbigniew Maniakowski; Dominika Oborska; Joanna Rostkowska; Małgorzata Kania
Journal:  Rep Pract Oncol Radiother       Date:  2010-03-30

2.  A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Authors:  Samuel L Brady; Rathnayaka Gunasingha; Terry T Yoshizumi; Calvin R Howell; Alexander S Crowell; Brent Fallin; Anton P Tonchev; Mark W Dewhirst
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

3.  Alkali Metal Salts of 10,12-Pentacosadiynoic Acid and Their Dosimetry Applications.

Authors:  Amy V Hall; Osama M Musa; David K Hood; David C Apperley; Dmitry S Yufit; Jonathan W Steed
Journal:  Cryst Growth Des       Date:  2021-03-25       Impact factor: 4.076

4.  Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

Authors:  Valeria Casanova Borca; Massimo Pasquino; Giuliana Russo; Pierangelo Grosso; Domenico Cante; Piera Sciacero; Giuseppe Girelli; Maria Rosa La Porta; Santi Tofani
Journal:  J Appl Clin Med Phys       Date:  2013-03-04       Impact factor: 2.102

5.  Reference dosimetry using radiochromic film.

Authors:  Frédéric Girard; Hugo Bouchard; Frédéric Lacroix
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  Investigation of EBT3 radiochromic film's response to humidity.

Authors:  Elsa Y León-Marroquín; José M Lárraga-Gutiérrez; J Alfredo Herrera-González; Miguel A Camacho-López; José E Villarreal Barajas; Olivia A García-Garduño
Journal:  J Appl Clin Med Phys       Date:  2018-04-29       Impact factor: 2.102

7.  Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.

Authors:  Andreas Franz Resch; Paul David Heyes; Hermann Fuchs; Niels Bassler; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2020-03-13       Impact factor: 4.071

8.  Diacetylene-Based Colorimetric Radiation Sensors for the Detection and Measurement of γ Radiation during Blood Irradiation.

Authors:  Apoorva Mittal; Shalini Verma; Gopishankar Natanasabapathi; Pratik Kumar; Akhilesh K Verma
Journal:  ACS Omega       Date:  2021-03-29

9.  The crystal engineering of radiation-sensitive diacetylene cocrystals and salts.

Authors:  Amy V Hall; Dmitry S Yufit; David C Apperley; Larry Senak; Osama M Musa; David K Hood; Jonathan W Steed
Journal:  Chem Sci       Date:  2020-07-20       Impact factor: 9.825

10.  Rapid Quantification and Validation of Biomarker Scopoletin in Paederia foetida by qNMR and UV-Vis for Herbal Preparation.

Authors:  Dai Chuan Tan; Alexandra Quek; Nur Kartinee Kassim; Intan Safinar Ismail; Joanna Jinling Lee
Journal:  Molecules       Date:  2020-11-06       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.