Literature DB >> 22163117

Application of a generalized scan statistic model to evaluate TOF PET images.

Suleman Surti1, Joel S Karp.   

Abstract

Noise equivalent counts (NEC) have been used as a measure or proxy of PET image quality for many years. It has been shown to be a useful metric, for example to determine clinical patient dosage. However, NEC should be used cautiously in evaluating image quality since it is a global data quality measure that does not take into account localized effects due to spatial resolution and image reconstruction, as well as the effect of time-of-flight (TOF) imaging on resultant images. In this work, we study the use of a numerical observer that uses a generalized scan-statistic model to estimate lesion detectability with localization in a uniform background phantom, for varying activity levels and scan times. Data were acquired on a clinical whole-body TOF PET scanner. Data show that ALROC increases as a function of NEC but at high activity levels it approaches a peak value earlier than the NEC peak. Also, the ALROC for images acquired with the same NEC, but at two different activity levels and scan times, is similar. Our results show that with TOF information we can either achieve improved clinical performance for heavy patients, or reduce the scan time or injected activity while maintaining similar ALROC value as in a Non-TOF image.

Entities:  

Year:  2011        PMID: 22163117      PMCID: PMC3234526          DOI: 10.1109/TNS.2010.2072791

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  10 in total

1.  Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET.

Authors:  Carole Lartizien; Claude Comtat; Paul E Kinahan; Nuno Ferreira; Bernard Bendriem; Régine Trébossen
Journal:  J Nucl Med       Date:  2002-09       Impact factor: 10.057

2.  Small nodule detectability evaluation using a generalized scan-statistic model.

Authors:  Lucreţiu M Popescu; Robert M Lewitt
Journal:  Phys Med Biol       Date:  2006-11-15       Impact factor: 3.609

3.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

4.  Continuous-slice PENN-PET: a positron tomograph with volume imaging capability.

Authors:  J S Karp; G Muehllehner; D A MankofF; C E Ordonez; J M Ollinger; M E Daube-Witherspoon; A T Haigh; D J Beerbohm
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

5.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

6.  3D PET using a conventional multislice tomograph without septa.

Authors:  S R Cherry; M Dahlbom; E J Hoffman
Journal:  J Comput Assist Tomogr       Date:  1991 Jul-Aug       Impact factor: 1.826

7.  Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities.

Authors:  Suleman Surti; Austin Kuhn; Matthew E Werner; Amy E Perkins; Jeffrey Kolthammer; Joel S Karp
Journal:  J Nucl Med       Date:  2007-03       Impact factor: 10.057

8.  Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans.

Authors:  Charles C Watson; Michael E Casey; Bernard Bendriem; Jonathan P Carney; David W Townsend; Stefan Eberl; Steve Meikle; Frank P Difilippo
Journal:  J Nucl Med       Date:  2005-11       Impact factor: 10.057

9.  Effect of noise correlation on detectability of disk signals in medical imaging.

Authors:  K J Myers; H H Barrett; M C Borgstrom; D D Patton; G W Seeley
Journal:  J Opt Soc Am A       Date:  1985-10       Impact factor: 2.129

10.  Experimental evaluation of a simple lesion detection task with time-of-flight PET.

Authors:  S Surti; J S Karp
Journal:  Phys Med Biol       Date:  2008-12-19       Impact factor: 3.609

  10 in total
  2 in total

1.  Determination of accuracy and precision of lesion uptake measurements in human subjects with time-of-flight PET.

Authors:  Margaret E Daube-Witherspoon; Suleman Surti; Amy E Perkins; Joel S Karp
Journal:  J Nucl Med       Date:  2014-03-06       Impact factor: 10.057

2.  Numerical observer study of lesion detectability for a long axial field-of-view whole-body PET imager using the PennPET Explorer.

Authors:  Varsha Viswanath; Margaret E Daube Witherspoon; Joel S Karp; Suleman Surti
Journal:  Phys Med Biol       Date:  2020-01-24       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.