Literature DB >> 16736147

Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

E Garcia-Rey1, E Garcia-Cimbrelo.   

Abstract

We assessed the clinical and radiographic results of 40 porous-coated acetabular cups with an Acetabular Cup System polyethylene liner over a minimum 14-year follow-up. Femoral head penetration was estimated using a software package. Fifteen cups were revised, 11 due to polyethylene liner rupture. All cups but two were radiographically stable, and 11 hips showed acetabular osteolysis. The overall femoral head penetration rate in hips without liner fracture with reference to the early penetration point was 0.1188+/-0.070 mm per year. Polyethylene liner fractures were associated with higher early femoral head penetration (P<0.0001) and a vertical cup position (P=0.0016). The 14-year survival without cup revision for any reason was 63.9%, 71.8% with no ACS polyethylene liner fracture and 65.3% with no acetabular osteolysis. Most cups showed a good clinical outcome in general, but major Acetabular Cup System liner failure and osteolysis were frequent. Patients with the ACS cups still in place should be monitored closely.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16736147      PMCID: PMC2267555          DOI: 10.1007/s00264-006-0151-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear.

Authors:  C J Sychterz; A M Yang; J P McAuley; C A Engh
Journal:  Clin Orthop Relat Res       Date:  1999-08       Impact factor: 4.176

2.  Effect of radiographic quality on computer-assisted head penetration measurements.

Authors:  C J Sychterz; A M Young; C A Engh
Journal:  Clin Orthop Relat Res       Date:  2001-05       Impact factor: 4.176

3.  Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty.

Authors:  Andrew J Hui; Richard W McCalden; John M Martell; Steven J MacDonald; Robert B Bourne; Cecil H Rorabeck
Journal:  J Bone Joint Surg Am       Date:  2003-03       Impact factor: 5.284

4.  The porous-coated anatomic total hip prosthesis: failure of the metal-backed acetabular component.

Authors:  D J Astion; P Saluan; B N Stulberg; C M Rimnac; S Li
Journal:  J Bone Joint Surg Am       Date:  1996-05       Impact factor: 5.284

5.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study.

Authors:  A Cruz-Pardos; E Garcia-Cimbrelo
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

8.  Hydroxyapatite-coated versus grit-blasted femoral stems. a prospective, randomised study using EBRA-FCA.

Authors:  M Hamadouche; J Witvoet; R Porcher; A Meunier; L Sedel; R Nizard
Journal:  J Bone Joint Surg Br       Date:  2001-09

9.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

10.  Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up.

Authors:  Karl F Orishimo; Alexandra M Claus; Christi J Sychterz; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

View more
  3 in total

1.  Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup.

Authors:  E García-Rey; E García-Cimbrelo
Journal:  Int Orthop       Date:  2007-01-31       Impact factor: 3.075

2.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

3.  No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups.

Authors:  Kristian Bjørgul; Wendy M Novicoff; S T Andersen; K Brevig; F Thu; M Wiig; O Ahlund
Journal:  J Orthop Traumatol       Date:  2010-03-03
  3 in total