Literature DB >> 11503118

The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study.

A Cruz-Pardos1, E Garcia-Cimbrelo.   

Abstract

A total of 93 Harris-Galante Porous I (HGP- I) prostheses were analyzed with a mean follow-up of 10.2 years. Thigh pain (28 hips) correlated with unstable fixation (P<.005), female gender (P<.045), young age (P<.05), poor distal femoral fill (P<.002), subsidence (P<.0001), and osteolysis (P<.05). Thirteen stems and 6 metallic shell cups were revised. Kaplan-Meier analysis showed 13-year survival rates of 92.5% +/- 5.8% for the metallic shell cup, 79.7% +/- 13% for the HGP-I cup, and 76.3% +/- 14.0% for the stem. Five polyethylene liners were changed because of wear >1 mm. Radiographic loosening occurred in 8 cups. Radiographic bone ingrowth was present in 54 stems, stable fibrous fixation was present in 24 stems, and unstable fixation was present in 15 stems. The mean polyethylene wear was 0.17 mm/y. Eleven hips (11.8%) had acetabular osteolysis, and 24 (25.8%) had femoral osteolysis, the latter being more frequent in unstable stems (P<.007). The HGP-I metallic cup shows better clinical and radiographic results than the stem, which frequently is associated with pain, unstable fixation, and osteolysis. Excessive polyethylene wear is frequent.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11503118     DOI: 10.1054/arth.2001.23921

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

Authors:  E Garcia-Rey; E Garcia-Cimbrelo
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

2.  The Bicontact cementless primary total hip arthroplasty: long-term results.

Authors:  Girish Swamy; Alistair Pace; Conal Quah; Peter Howard
Journal:  Int Orthop       Date:  2010-09-10       Impact factor: 3.075

3.  Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup.

Authors:  E García-Rey; E García-Cimbrelo
Journal:  Int Orthop       Date:  2007-01-31       Impact factor: 3.075

4.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

5.  Average 22-Year Results of Total Hip Arthroplasty Using Harris-Galante Prosthesis in Patients under 50 Years.

Authors:  Heejae Won; Seung-Hoon Baek; Junekyu Kim; Won Kee Lee; Yeon Soo Lee; Shin-Yoon Kim
Journal:  Clin Orthop Surg       Date:  2022-03-03

6.  Retrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years.

Authors:  Keisha French; Rebecca Moore; Heather Gawel; Steven M Kurtz; Matthew J Kraay; Ke Xie; Victor M Goldberg; Clare M Rimnac
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.