Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear.

C J Sychterz1, A M Yang, J P McAuley, C A Engh.   

Abstract

Because polyethylene wear adversely affects the outcome of total hip arthroplasty, reliable techniques for in vivo radiographic evaluation of femoral head penetration into the polyethylene liner are needed. With the recent development of software to measure three-dimensional femoral head penetration, the adequacy of two-dimensional head penetration measurements to estimate a three-dimensional process has been questioned. Thus, the purpose of the current study was to compare directly two-dimensional and three-dimensional radiographic measurements of femoral head penetration. Using two computer assisted radiographic techniques, the authors of this study measured the two-dimensional and the three-dimensional penetration of the femoral head into the polyethylene liner in 202 hips implanted with porous coated acetabular components. A comparison of two-dimensional and three-dimensional measurements showed that, on average, the mean amount of three-dimensional head penetration was larger than the mean amount of two-dimensional head penetration. However, linear regression analysis showed that the two measurements were highly correlated (r2 = 0.87, slope = 0.99, intercept = 0.08 mm). For most patients (95%), two-dimensional and three-dimensional measurements of femoral head penetration were nearly equal. However, there was a small subset of patients (5%) for whom three-dimensional radiographic penetration measurements were three times greater than corresponding two-dimensional radiographic penetration measurements. No common risk factor among this small subset of patients was identified. The current study provides practical information for the orthopaedic surgeon trying to assess polyethylene wear in hip replacement cases. It shows that for most patients head penetration can be measured sufficiently from anteroposterior radiographs alone. However, in a small percentage of patients (5% in the current study) the femoral head also moves perpendicular to the plane of the anteroposterior radiograph. For these cases, accurate analysis of head penetration requires three-dimensional analysis using anteroposterior and lateral radiographs.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10627695     DOI: 10.1097/00003086-199908000-00016

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

2.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

3.  Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

Authors:  E Garcia-Rey; E Garcia-Cimbrelo
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

4.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

5.  Early reactive synovitis and osteolysis after total hip arthroplasty.

Authors:  H John Cooper; Amar S Ranawat; Hollis G Potter; Li Foong Foo; Trevor W Koob; Chitranjan S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

6.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

7.  Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years.

Authors:  Maiken Stilling; Ole Rahbek; Kjeld Søballe
Journal:  Clin Orthop Relat Res       Date:  2009-03-28       Impact factor: 4.176

8.  The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty. A study of validity and reliability.

Authors:  Maiken Stilling; Kristian Larsen; Niels T Andersen; Kjeld Søballe; Søren Kold; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

9.  Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups.

Authors:  Brian Derbyshire; Bilal Barkatali
Journal:  Med Eng Phys       Date:  2017-07-03       Impact factor: 2.242

10.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853