Literature DB >> 11603537

Hydroxyapatite-coated versus grit-blasted femoral stems. a prospective, randomised study using EBRA-FCA.

M Hamadouche1, J Witvoet, R Porcher, A Meunier, L Sedel, R Nizard.   

Abstract

We have carried out a prospective, randomised study designed to compare the long-term stability of the stem of cementless femoral implants with differing surface configurations. A total of 50 hips (46 patients) was randomised into two groups, according to whether the medullary stem had been grit blasted (GB) or coated with hydroxyapatite (HA). Both femoral prostheses were of the same geometrical design. We used Ein Bild Roentgen Analyse femoral component analysis (EBRA-FCA) to assess the stability of the stem. The mean follow-up was for 8.66 years. The mean migration of the stem was 1.26 mm in the HA group compared with 2.57 mm in the GB group (Mann-Whitney U test, p = 0.04). A mixed model ANOVA showed that the development of subsidence was statistically different in the two groups during the first 24 months. After this subsidence increased in both groups with no difference between them. Our results indicate that, with the same design of stem, HA coating enhanced the stability of the femoral stem when compared with GB stems.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11603537     DOI: 10.1302/0301-620x.83b7.11478

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation.

Authors:  Artur Kroell; Paul Beaulé; Martin Krismer; Hannes Behensky; Bernd Stoeckl; Rainer Biedermann
Journal:  Int Orthop       Date:  2008-12-06       Impact factor: 3.075

2.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09

3.  Bioactive borate glass coatings for titanium alloys.

Authors:  Laxmikanth Peddi; Richard K Brow; Roger F Brown
Journal:  J Mater Sci Mater Med       Date:  2008-04-15       Impact factor: 3.896

4.  Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

Authors:  E Garcia-Rey; E Garcia-Cimbrelo
Journal:  Int Orthop       Date:  2006-05-31       Impact factor: 3.075

5.  High incidence of migration with poor initial fixation of the Accolade stem.

Authors:  Craig A White; Sasha Carsen; Kevin Rasuli; Robert J Feibel; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 6.  On the fate of particles liberated from hydroxyapatite coatings in vivo.

Authors:  C F Dunne; J Gibbons; D P FitzPatrick; K J Mulhall; K T Stanton
Journal:  Ir J Med Sci       Date:  2015-01-10       Impact factor: 1.568

7.  Biomineral/Agarose Composite Gels Enhance Proliferation of Mesenchymal Stem Cells with Osteogenic Capability.

Authors:  Yoshika Suzawa; Norihiko Kubo; Soichi Iwai; Yoshiaki Yura; Hajime Ohgushi; Mitsuru Akashi
Journal:  Int J Mol Sci       Date:  2015-06-23       Impact factor: 5.923

8.  Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis.

Authors:  Yun-Lin Chen; Tiao Lin; An Liu; Ming-Min Shi; Bin Hu; Zhong-Li Shi; Shi-Gui Yan
Journal:  J Orthop Surg Res       Date:  2015-01-28       Impact factor: 2.359

9.  Local inhibition of 5-lipoxygenase enhances bone formation in a rat model.

Authors:  J A Cottrell; V Keshav; A Mitchell; J P O'Connor
Journal:  Bone Joint Res       Date:  2013-02-01       Impact factor: 5.853

10.  Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

Authors:  Thierry Scheerlinck; Mathias Polfliet; Rudi Deklerck; Gert Van Gompel; Nico Buls; Jef Vandemeulebroucke
Journal:  Acta Orthop       Date:  2015-12-03       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.