Phased array ghost elimination.

Peter Kellman1, Elliot R McVeigh.   

Abstract

Parallel imaging may be applied to cancel ghosts caused by a variety of distortion mechanisms, including distortions such as off-resonance or local flow, which are space variant. Phased array combining coefficients may be calculated that null ghost artifacts at known locations based on a constrained optimization, which optimizes SNR subject to the nulling constraint. The resultant phased array ghost elimination (PAGE) technique is similar to the method known as sensitivity encoding (SENSE) used for accelerated imaging; however, in this formulation is applied to full field-of-view (FOV) images. The phased array method for ghost elimination may result in greater flexibility in designing acquisition strategies. For example, in multi-shot EPI applications ghosts are typically mitigated by the use of an interleaved phase encode acquisition order. An alternative strategy is to use a sequential, non-interleaved phase encode order and cancel the resultant ghosts using PAGE parallel imaging. Cancellation of ghosts by means of phased array processing makes sequential, non-interleaved phase encode acquisition order practical, and permits a reduction in repetition time, TR, by eliminating the need for echo-shifting. Sequential, non-interleaved phase encode order has benefits of reduced distortion due to off-resonance, in-plane flow and EPI delay misalignment. Furthermore, the use of EPI with PAGE has inherent fat-water separation and has been used to provide off-resonance correction using a technique referred to as lipid elimination with an echo-shifting N/2-ghost acquisition (LEENA), and may further generalized using the multi-point Dixon method. Other applications of PAGE include cancelling ghosts which arise due to amplitude or phase variation during the approach to steady state. Parallel imaging requires estimates of the complex coil sensitivities. In vivo estimates may be derived by temporally varying the phase encode ordering to obtain a full k-space dataset in a scheme similar to the autocalibrating TSENSE method. This scheme is a generalization of the UNFOLD method used for removing aliasing in undersampled acquisitions. The more general scheme may be used to modulate each EPI ghost image to a separate temporal frequency as described in this paper. Copyright (c) 2006 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2006        PMID: 16705636      PMCID: PMC2041875          DOI: 10.1002/nbm.1044

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  18 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Segmented k-space fast cardiac imaging using an echo-train readout.

Authors:  F H Epstein; S D Wolff; A E Arai
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

5.  Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; B D Bolster; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

6.  Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging.

Authors:  F Farzaneh; S J Riederer; N J Pelc
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

7.  Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan.

Authors:  X Wan; G T Gullberg; D L Parker; G L Zeng
Journal:  Magn Reson Med       Date:  1997-06       Impact factor: 4.668

8.  Ultrafast interleaved gradient-echo-planar imaging on a standard scanner.

Authors:  G C McKinnon
Journal:  Magn Reson Med       Date:  1993-11       Impact factor: 4.668

9.  Cardiac echo-planar MR imaging: comparison of single- and multiple-shot techniques.

Authors:  D R Wetter; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Radiology       Date:  1995-03       Impact factor: 11.105

10.  Phase errors in multi-shot echo planar imaging.

Authors:  D A Feinberg; K Oshio
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

View more
  12 in total

1.  Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

Authors:  Benedikt A Poser; Markus Barth; Pål-Erik Goa; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

2.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

Review 3.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

4.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

5.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

6.  Lipid elimination with an echo-shifting N/2-ghost acquisition (LEENA) MRI.

Authors:  Lan Lu; Shannon B Donnola; Michaela Koontz; Mark A Griswold; Jeffrey L Duerk; Chris A Flask
Journal:  Magn Reson Med       Date:  2014-03-17       Impact factor: 4.668

7.  Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

Authors:  Julianna D Ianni; E Brian Welch; William A Grissom
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

8.  Model-based iterative reconstruction for single-shot EPI at 7T.

Authors:  Uten Yarach; Myung-Ho In; Itthi Chatnuntawech; Berkin Bilgic; Frank Godenschweger; Hendrik Mattern; Alessandro Sciarra; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

9.  Nyquist ghost correction of breast diffusion weighted imaging using referenceless methods.

Authors:  Jessica A McKay; Steen Moeller; Lei Zhang; Edward J Auerbach; Michael T Nelson; Patrick J Bolan
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

10.  Characterization of Nyquist ghost in EPI-fMRI acquisition sequences implemented on two clinical 1.5 T MR scanner systems: effect of readout bandwidth and echo spacing.

Authors:  Marco Giannelli; Stefano Diciotti; Carlo Tessa; Mario Mascalchi
Journal:  J Appl Clin Med Phys       Date:  2010-07-12       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.