Literature DB >> 7997122

Phase errors in multi-shot echo planar imaging.

D A Feinberg1, K Oshio.   

Abstract

Field inhomogeneity related phase errors in multi-shot echo planar imaging (EPI) are directly visualized and analyzed in the spatial frequency domain data or 'k-space'. The echo time shift (ETS) technique incrementally moves the position of the echo train and improves the phase error function by redistributing phase discontinuities away from the center of k-space.

Mesh:

Year:  1994        PMID: 7997122     DOI: 10.1002/mrm.1910320418

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  A novel object-independent "balanced" reference scan for echo-planar imaging.

Authors:  S B Reeder; A Z Faranesh; E Atalar; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

3.  MR CAT scan: a modular approach for hybrid imaging.

Authors:  C Hillenbrand; D Hahn; A Haase; P M Jakob
Journal:  MAGMA       Date:  2000-07       Impact factor: 2.310

4.  Ghost artifact cancellation using phased array processing.

Authors:  P Kellman; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

5.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

6.  A method for simultaneous echo planar imaging of hyperpolarized ¹³C pyruvate and ¹³C lactate.

Authors:  Galen D Reed; Peder E Z Larson; Cornelius von Morze; Robert Bok; Michael Lustig; Adam B Kerr; John M Pauly; John Kurhanewicz; Daniel B Vigneron
Journal:  J Magn Reson       Date:  2012-02-24       Impact factor: 2.229

7.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

8.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

9.  Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Authors:  Daniel A Herzka; J Andrew Derbyshire; Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

10.  Phased array ghost elimination.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.