Literature DB >> 2352469

Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging.

F Farzaneh1, S J Riederer, N J Pelc.   

Abstract

Several aspects of blipped echo-planar imaging (EPI) are treated mathematically. An expression relating the necessary readout gradient strength and sampling time to the spatial resolution and readout duration is derived. It is shown how the net spatial resolution may be limited by the object's T2 characteristics and B0 field homogeneity, irrespective of the number of sampled points. Additionally, off-resonance effects result in a loss of spatial resolution and image distortion to a considerably greater degree than in conventional two-dimensional Fourier transform imaging. The extent of these effects is directly related to the time required to acquire the data matrix, and is therefore amplified when EPI is implemented on a standard commercial whole-body system which because of limited gradient performance uses necessarily longer sampling durations. Specific hardware modifications to a standard commercial imager are considered to allow successful EPI implementation. EPI image characteristics are compared quantitatively with those of conventional methods.

Mesh:

Year:  1990        PMID: 2352469     DOI: 10.1002/mrm.1910140112

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  76 in total

1.  3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  Int J Card Imaging       Date:  1999-04

2.  Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

3.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

4.  Ghost artifact cancellation using phased array processing.

Authors:  P Kellman; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

5.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

6.  Single-shot magnetic resonance imaging: applications to angiography.

Authors:  A P Crawley; M S Cohen; E K Yucel; B Poncelet; T J Brady
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

7.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

8.  Motion immune diffusion imaging using augmented MUSE for high-resolution multi-shot EPI.

Authors:  Shayan Guhaniyogi; Mei-Lan Chu; Hing-Chiu Chang; Allen W Song; Nan-Kuei Chen
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

9.  Simultaneous estimation of tongue volume and fat fraction using IDEAL-FSE.

Authors:  Ianessa A Humbert; Scott B Reeder; Eva J Porcaro; Stephanie A Kays; Jean H Brittain; Joanne Robbins
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

10.  Rapid simultaneous acquisition of T1 and T2 mapping images using multishot double spin-echo EPI and automated variations of TR and TE (ms-DSEPI-T12).

Authors:  Xin Liu; Yi Feng; Zheng-Rong Lu; Glen Morrell; Eun-Kee Jeong
Journal:  NMR Biomed       Date:  2010-01       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.