Literature DB >> 16628443

Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

M Reinhold1, F Magerl, M Rieger, M Blauth.   

Abstract

This morphometric and experimental study was designed to assess the dimensions and axes of the subaxial cervical pedicles and to compare the accuracy of two different techniques for subaxial cervical pedicle screw (CPS) placement using newly designed aiming devices. Transpedicular fixation is increasingly used for stabilizing the subaxial cervical spine. Development of the demanding technique is based on morphometric studies of the pedicle anatomy. Several surgical techniques have been developed and evaluated with respect to their feasibility and accuracy. The study was carried out on six conserved human cadavers (average age 85 years). Axes and dimensions of the pedicles C3-C7 (60 pedicles) were measured using multislice computed tomography (CT) images prior to surgery. Two groups consisting of 3 specimens and 30 pedicles each were established according to the screw placement technique. For surgical technique 1 (ST1) a para-articular mini-laminotomy was performed. Guidance of the drill through the pedicle with a handheld aiming device attached onto the medial aspect of the pedicle inside the spinal canal. Screw hole preparation monitored by lateral fluoroscopy. In surgical technique 2 (ST2) a more complex aiming device was used for screw holes drilling. It consists of a frame with a fully adjustable radiolucent arm for carrying the instruments necessary for placing the screws. The arm was angled according to the cervical pedicle axis as determined by the preoperative CT scans. Drilling was monitored by lateral fluoroscopy. In either technique 3.5 mm screws made of carbon fiber polyetheretherketone (CF-PEEK) were inserted. The use of the CF-PEEK screws allowed for precise postoperative CT-assessment since this material does not cause artifacts. Screw placement was qualified from ideal to unacceptable into four grades: I = screw centered in pedicle; IIa = perforation of pedicle wall less than one-fourth of the screw diameter; IIb = perforation more than one-fourth of the screw diameter without contact to neurovascular structures; III = screw more than one-fourth outside the pedicle with contact to neurovascular structures. Fifty-six pedicle screws could be evaluated according to the same CT protocol that was used preoperatively. Accuracy of pedicle screw placement did not reveal significant differences between techniques 1 and 2. A tendency towards less severe misplacements (grade III) was seen in ST2 (15% in ST2 vs. 23% in ST1) as well as a higher rate of screw positions graded IIa (62% in ST2 vs. 43% in ST1). C4 and C5 were identified to be the most critical vertebral levels with three malpositioned screws each. Because of the variability of cervical pedicles preoperative CT evaluation with multiplanar reconstructions of the pedicle anatomy is essential for transpedicular screw placement in the cervical spine. Cadaver studies remain mandatory to develop safer and technically less demanding procedures. A similar study is projected to further develop the technique of CPS fixation with regard to safety and clinical practicability.

Entities:  

Mesh:

Year:  2006        PMID: 16628443      PMCID: PMC2198884          DOI: 10.1007/s00586-006-0104-1

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  48 in total

1.  Cervical spine pedicle screws: a biomechanical comparison of two insertion techniques.

Authors:  J M Kowalski; S C Ludwig; W C Hutton; J G Heller
Journal:  Spine (Phila Pa 1976)       Date:  2000-11-15       Impact factor: 3.468

2.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

3.  Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization.

Authors:  E E Karaikovic; S Kunakornsawat; M D Daubs; T W Madsen; R W Gaines
Journal:  J Spinal Disord       Date:  2000-02

4.  Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.

Authors:  Takeshi Sakamoto; Masashi Neo; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2004-11-15       Impact factor: 3.468

5.  Morphometric evaluation of subaxial cervical vertebrae for surgical application of transpedicular screw fixation.

Authors:  Mustafa Bozbuga; Adnan Ozturk; Zafer Ari; Kayihan Sahinoglu; Bulent Bayraktar; Aycicek Cecen
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

6.  Internal architecture of the thoracic pedicle. An anatomic study.

Authors:  R Kothe; J D O'Holleran; W Liu; M M Panjabi
Journal:  Spine (Phila Pa 1976)       Date:  1996-02-01       Impact factor: 3.468

7.  Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.

Authors:  Y Kotani; B W Cunningham; K Abumi; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

8.  Pedicle screw fixation for nontraumatic lesions of the cervical spine.

Authors:  K Abumi; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

9.  Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.

Authors:  Ralph Kothe; Wolfgang Rüther; Erich Schneider; Berend Linke
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

10.  Posterior plates in the management of cervical instability: long-term results in 44 patients.

Authors:  M G Fehlings; P R Cooper; T J Errico
Journal:  J Neurosurg       Date:  1994-09       Impact factor: 5.115

View more
  39 in total

1.  The use of pedicle screw-rod system for the posterior fixation in cervico-thoracic junction.

Authors:  Wonik Cho; Ahmed Shawky Eid; Ung-Kyu Chang
Journal:  J Korean Neurosurg Soc       Date:  2010-07-31

2.  Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique.

Authors:  Shaunak Desai; Anil Sethi; Christopher C Ninh; Stephen Bartol; Rahul Vaidya
Journal:  Eur Spine J       Date:  2010-07-17       Impact factor: 3.134

3.  Comparison of perpendicular to the coronal plane versus medial inclination for atlas pedicle screw insertion: an anatomic and radiological study in human cadavers.

Authors:  Jun Ma; Jian Tang; Deguang Wang; Yucheng Zhu; Tao Sui; Xiaojian Cao
Journal:  Int Orthop       Date:  2015-08-15       Impact factor: 3.075

Review 4.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

5.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

6.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

7.  An analysis of the anatomic features of the cervical spine using computed tomography to select safer screw insertion techniques.

Authors:  Masahiro Nishinome; Haku Iizuka; Yoichi Iizuka; Kenji Takagishi
Journal:  Eur Spine J       Date:  2013-07-06       Impact factor: 3.134

8.  A clinical morphologic study of the C2 pedicle and isthmus.

Authors:  Feng Yuan; Hui-Lin Yang; Kai-Jin Guo; Jiang-Shan Li; Kai Xu; Zhi-Ming Zhang; Tian-Si Tang
Journal:  Eur Spine J       Date:  2012-08-14       Impact factor: 3.134

9.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

10.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

View more