Literature DB >> 14634850

Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Marcus Richter1, Thomas Mattes, Balkan Cakir.   

Abstract

Posterior instrumentation of the cervical spine has become increasingly popular in recent years. Dissatisfaction with lateral mass fixation, especially at the cervico-thoracic junction, has led spine surgeons to use pedicle screws. The improved biomechanical stability of pedicle screws and transarticular C1/2 screws allows for shorter instrumentations and improves the repositioning possibilities. Nevertheless, there are potential risks of iatrogenic damage to the spinal cord, nerve roots or the vertebral artery with both techniques. Therefore, the aim of this study was to evaluate whether C1/2 transarticular screws and transpedicular screws can be applied safely and with high accuracy in the cervical spine and the cervico-thoracic junction using a computer-assisted surgery system (CAS system). Posterior instrumentation was performed using the Brainlab VectorVision System (BrainLAB, Heimstetten, Germany) in 19 patients. Surface matching was used for registration. We placed 22 transarticular screws C1/2, 31 cervical pedicle screws, 10 high thoracic pedicle screws and one lateral mass screw C1. The screw position was evaluated postoperatively using CT with multiplanar reconstruction in the screw axis of each screw. None of the transarticular screws or pedicle screws was significantly (>2 mm) misplaced and no screw-related injury to vascular, neurogenic or bony structures was observed. No screw revision was necessary. The mean operation time was 144 min (90-240 min) and the mean blood loss was 234 ml (50-800 ml). C1/2 transarticular screws, as well as transpedicular screws in the cervical spine and the cervico-thoracic junction, can be applied safely and with high accuracy using a CAS system. Computer-assisted instrumentation is recommended especially for pedicle screws at C3-C6.

Entities:  

Mesh:

Year:  2003        PMID: 14634850      PMCID: PMC3468035          DOI: 10.1007/s00586-003-0604-1

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  48 in total

1.  [Dynamic change in the ligmenta flava of the cervical spine in motion].

Authors:  L S Jia
Journal:  Zhonghua Wai Ke Za Zhi       Date:  1989-09

2.  Application of frameless stereotaxy to pedicle screw fixation of the spine.

Authors:  I H Kalfas; D W Kormos; M A Murphy; R L McKenzie; G H Barnett; G R Bell; C P Steiner; M B Trimble; J P Weisenberger
Journal:  J Neurosurg       Date:  1995-10       Impact factor: 5.115

3.  Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment.

Authors:  A R Vaccaro; S J Rizzolo; R A Balderston; T J Allardyce; S R Garfin; C Dolinskas; H S An
Journal:  J Bone Joint Surg Am       Date:  1995-08       Impact factor: 5.284

4.  The reliability of the lateral radiograph in determination of the optimal transarticular C1-C2 screw length.

Authors:  R Xu; N A Ebraheim; J R Misson; R A Yeasting
Journal:  Spine (Phila Pa 1976)       Date:  1998-10-15       Impact factor: 3.468

5.  Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients.

Authors:  T Laine; K Mäkitalo; D Schlenzka; K Tallroth; M Poussa; A Alho
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

6.  Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer.

Authors:  S Lavallée; P Sautot; J Troccaz; P Cinquin; P Merloz
Journal:  J Image Guid Surg       Date:  1995

7.  Planning and insertion of pedicle screws with computer assistance.

Authors:  U Berlemann; D Monin; E Arm; L P Nolte; C Ozdoba
Journal:  J Spinal Disord       Date:  1997-04

8.  Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.

Authors:  Y Kotani; B W Cunningham; K Abumi; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

9.  Vertebral artery location in relation to the vertebral body as determined by two-dimensional computed tomography evaluation.

Authors:  A R Vaccaro; D Ring; G Scuderi; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  1994-12-01       Impact factor: 3.468

10.  Pedicle screw fixation for nontraumatic lesions of the cervical spine.

Authors:  K Abumi; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

View more
  45 in total

1.  [CAS-guided correction arthrodesis of the tarsometatarsal and midfoot joints].

Authors:  M Richter
Journal:  Oper Orthop Traumatol       Date:  2011-10       Impact factor: 1.154

2.  [Computer-assisted surgery-(CAS-)guided correction arthrodesis of the subtalar joint].

Authors:  Martinus Richter
Journal:  Oper Orthop Traumatol       Date:  2010-10       Impact factor: 1.154

3.  Cervical pedicle screw insertion using a gutter entry point at the transitional area between the lateral mass and lamina.

Authors:  Katsuhiro Tofuku; Hiroaki Koga; Setsuro Komiya
Journal:  Eur Spine J       Date:  2011-08-10       Impact factor: 3.134

4.  Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.

Authors:  Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein
Journal:  Eur Spine J       Date:  2016-01-25       Impact factor: 3.134

5.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

6.  Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results.

Authors:  Heiko Koller; Volker Kammermeier; Dietmar Ulbricht; Allan Assuncao; Stefan Karolus; Boris van den Berg; Ulrich Holz
Journal:  Eur Spine J       Date:  2006-04-08       Impact factor: 3.134

7.  Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability.

Authors:  Jian Wang; Yue Zhou; ZhengFeng Zhang; ChangQing Li; WenJie Zheng; Yuan Zhang
Journal:  Eur Spine J       Date:  2012-08       Impact factor: 3.134

8.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

9.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

10.  [Computer-assisted surgery-(CAS-) guided correction arthrodesis of the ankle joint].

Authors:  Martinus Richter
Journal:  Oper Orthop Traumatol       Date:  2009-09       Impact factor: 1.154

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.