Literature DB >> 15534408

Morphometric evaluation of subaxial cervical vertebrae for surgical application of transpedicular screw fixation.

Mustafa Bozbuga1, Adnan Ozturk, Zafer Ari, Kayihan Sahinoglu, Bulent Bayraktar, Aycicek Cecen.   

Abstract

STUDY
DESIGN: A morphometric evaluation of pedicle projections in 29 cervical spinal columns (C3-C7) for three-dimensional surgical anatomy for safe surgery was proposed.
OBJECTIVE: In this study, pedicles and intimate structures of the subaxial vertebrae from C3 to C7 were evaluated to provide some morphometric data for cervical transpedicular screw fixation. SUMMARY OF BACKGROUND DATA: Detailed knowledge of surgical anatomy and variation of the subaxial vertebrae is a must for safe and effective surgery of the region. Although there are several clinical studies of transpedicular fixation, few studies have been performed on cervical pedicle measurements and their projection.
METHODS: In 29 dried bone cervical spinal columns (C3-C7), pedicle dimensions (pedicle height, width, length), measurements of lateral mass and pedicle length distance and pedicle axis length, investigation of distances of superior facet-midpedicle axis and inferior facet-midpedicle axis, and transverse and sagittal angles of the pedicles were performed in linear and angular measurements.
RESULTS: The obtained data from the series revealed that the mean values were approximately ranging from 6.7 to 7.2 mm for pedicle height, 4.4 to 4.9 mm for pedicle width, 5.3 to 6.2 mm for pedicle length, 15.3 to 16.0 mm for lateral mass and pedicle length, 22.2 to 27.7 mm for pedicle axis length, 3.8 to 5.3 mm for superior facet-midpedicle axis distance, 9.9 to 12.0 mm for inferior facet-midpedicle axis distance, 42.3 degrees to 51.5 degrees for transverse angle, and 5.2 degrees to 14.1 degrees for sagittal angle.
CONCLUSIONS: Linear measurements of pedicle dimensions and also axial angles from horizontal and vertical planes may provide some anatomic limitations for subaxial cervical transpedicular screw fixation, and also contribute to the safety of the surgical procedure. One should also rely on tomographic data and computer-assisted guidance systems.

Entities:  

Mesh:

Year:  2004        PMID: 15534408     DOI: 10.1097/01.brs.0000137065.62516.01

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  17 in total

1.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

2.  CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Authors:  Zhu Ruofu; Yang Huilin; Hu Xiaoyun; He Xishun; Tang Tiansi; Chen Liang; Li Xigong
Journal:  Surg Radiol Anat       Date:  2008-03-20       Impact factor: 1.246

Review 3.  Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literature.

Authors:  M Reinhold; C Bach; L Audigé; R Bale; R Attal; M Blauth; F Magerl
Journal:  Eur Spine J       Date:  2008-01-22       Impact factor: 3.134

4.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

5.  The contralateral lamina: a reliable guide in subaxial, cervical pedicle screw placement.

Authors:  A G Hacker; S Molloy; J Bernard
Journal:  Eur Spine J       Date:  2008-09-16       Impact factor: 3.134

6.  The ipsilateral lamina-pedicle angle: can it be used to guide pedicle screw placement in the sub-axial cervical spine?

Authors:  Edward Bayley; Zergham Zia; Robert Kerslake; Bronek M Boszczyk
Journal:  Eur Spine J       Date:  2009-09-01       Impact factor: 3.134

7.  Morphometry of typical cervical vertebrae on dry bones and CT scan and its implications in transpedicular screw placement surgery.

Authors:  Richa Gupta; Kanchan Kapoor; Anshu Sharma; Suman Kochhar; Rajeev Garg
Journal:  Surg Radiol Anat       Date:  2012-09-09       Impact factor: 1.246

8.  Computed tomographic morphometric analysis of cervical pedicles in a multi-ethnic Asian population and relevance to subaxial cervical pedicle screw fixation.

Authors:  Thangaraj Munusamy; Ady Thien; Mark Gerad Anthony; Ramesh Bakthavachalam; Shree Kumar Dinesh
Journal:  Eur Spine J       Date:  2014-08-26       Impact factor: 3.134

9.  Morphometric Analysis of Sub-axial Cervical Vertebrae and Its Surgical Implications.

Authors:  Sandeep Saluja; Sachin Patil; Neelam Vasudeva
Journal:  J Clin Diagn Res       Date:  2015-11-01

10.  Computerized Tomography-Based Morphometric Analysis of Subaxial Cervical Spine Pedicle in Asymptomatic Indian Population.

Authors:  Kamran Farooque; Rahul Yadav; Buddhadev Chowdhury; Shivanand Gamanagatti; Atin Kumar; Pradeep Kumar Meena
Journal:  Int J Spine Surg       Date:  2018-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.