Literature DB >> 20640455

Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique.

Shaunak Desai1, Anil Sethi, Christopher C Ninh, Stephen Bartol, Rahul Vaidya.   

Abstract

Cervical pedicle screws have been reported to be biomechanically superior to lateral mass screws. However, placement of these implants is a technical challenge. The purpose of this investigation was to use an anatomic and a clinical study to evaluate a technique for placement of the pedicle screws in the C7 vertebra using fluoroscopic imaging in only the anteroposterior (A/P) plane. Ten adult cadaver C7 vertebrae were used to record the pedicle width, inclination and a suitable entry point for placement of pedicle screws. A prospective study of 28 patients undergoing posterior instrumentation of the cervical spine with C7 pedicle screw placement was also performed. A total of 55 C7 pedicle screws were placed using imaging only in the A/P plane with screw trajectory values obtained by the anatomic study. Radiographs and CT scans were performed post-operatively. The average posterior pedicle diameter of C7 vertebra was 9.5 ± 1.2 mm in this study. The average middle pedicle diameter was 7.1 mm and the average anterior pedicle diameter was 9.2 mm. The average transverse pedicle angle was 26.8 on the right and 27.3 on the left. CT scans were obtained on 20 of 28 patients which showed two asymptomatic cortical wall perforations. One screw penetrated the lateral wall of the pedicle and another displayed an anterior vertebral penetration. There were no medial wall perforations. The preliminary results suggest that this technique is safe and suitable for pedicle screw placement in the C7 vertebra.

Entities:  

Mesh:

Year:  2010        PMID: 20640455      PMCID: PMC2989253          DOI: 10.1007/s00586-010-1513-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  12 in total

1.  Cervical pedicle screws: comparative accuracy of two insertion techniques.

Authors:  S C Ludwig; J M Kowalski; C C Edwards; J G Heller
Journal:  Spine (Phila Pa 1976)       Date:  2000-10-15       Impact factor: 3.468

2.  Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques.

Authors:  S C Ludwig; D L Kramer; R A Balderston; A R Vaccaro; K F Foley; T J Albert
Journal:  Spine (Phila Pa 1976)       Date:  2000-07-01       Impact factor: 3.468

3.  Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization.

Authors:  E E Karaikovic; S Kunakornsawat; M D Daubs; T W Madsen; R W Gaines
Journal:  J Spinal Disord       Date:  2000-02

4.  Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Authors:  M Reinhold; F Magerl; M Rieger; M Blauth
Journal:  Eur Spine J       Date:  2006-04-21       Impact factor: 3.134

5.  Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope.

Authors:  Yasutsugu Yukawa; Fumihiko Kato; Keigo Ito; Yumiko Horie; Tetsurou Hida; Hiroaki Nakashima; Masaaki Machino
Journal:  Eur Spine J       Date:  2009-06-02       Impact factor: 3.134

6.  Cervical human vertebrae. Quantitative three-dimensional anatomy of the middle and lower regions.

Authors:  M M Panjabi; J Duranceau; V Goel; T Oxland; K Takata
Journal:  Spine (Phila Pa 1976)       Date:  1991-08       Impact factor: 3.468

7.  Morphological survey of the cervicothoracic junctional region.

Authors:  J J Boyle; K P Singer; N Milne
Journal:  Spine (Phila Pa 1976)       Date:  1996-03-01       Impact factor: 3.468

8.  Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison.

Authors:  E L Jones; J G Heller; D H Silcox; W C Hutton
Journal:  Spine (Phila Pa 1976)       Date:  1997-05-01       Impact factor: 3.468

9.  Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect.

Authors:  R Xu; N A Ebraheim; R Yeasting; F Wong; W T Jackson
Journal:  J Spinal Disord       Date:  1995-04

10.  Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique.

Authors:  C Barrey; F Cotton; J Jund; P Mertens; G Perrin
Journal:  Surg Radiol Anat       Date:  2003-09-03       Impact factor: 1.246

View more
  7 in total

1.  Surgical challenges in posterior cervicothoracic junction instrumentation.

Authors:  Alberto Balestrino; Renato Gondar; Gianpaolo Jannelli; Gianluigi Zona; Enrico Tessitore
Journal:  Neurosurg Rev       Date:  2021-03-22       Impact factor: 3.042

2.  A computed tomography-based anatomic comparison of three different types of c7 posterior fixation techniques : pedicle, intralaminar, and lateral mass screws.

Authors:  Woo Young Jang; Il Sup Kim; Ho Jin Lee; Jae Hoon Sung; Sang Won Lee; Jae Taek Hong
Journal:  J Korean Neurosurg Soc       Date:  2011-09-30

3.  Easy method to simplify "freehand" subaxial cervical pedicle screw insertion.

Authors:  Alexander V Burcev; Olga M Pavlova; Konstantin A Diachkov; Galina V Diachkova; Sergey O Ryabykh; Alexander V Gubin
Journal:  J Craniovertebr Junction Spine       Date:  2017 Oct-Dec

4.  Comparison of Three Different Options for C7 Posterior Vertebral Anchor in the Indian Population-Lateral Mass, Pedicle, and Lamina: A Computed Tomography-Based Morphometric Analysis.

Authors:  Vibhu Krishnan Viswanathan; Surabhi Subramanian; Sushma Viswanathan
Journal:  Asian Spine J       Date:  2018-07-27

5.  Validation of Freehand Cervical Pedicle Screw Placement in Subaxial Spine Using the "Burcev Technique": A Cadaveric Study.

Authors:  Mantu Jain; Rabi N Sahu; Manisha R Gaikwad; Sashikanta Panda; Amit Tirpude; Nerbadyswari D Bag
Journal:  J Neurosci Rural Pract       Date:  2021-05-07

6.  Lumbar pedicle screw placement: Using only AP plane imaging.

Authors:  Anil Sethi; Adrienne Lee; Rahul Vaidya
Journal:  Indian J Orthop       Date:  2012-07       Impact factor: 1.251

7.  Safety and efficacy of lateral mass screws at C7 in the treatment of cervical degenerative disease.

Authors:  Chengmin Zhang; Qiang Zhou; Paul M Arnold
Journal:  Surg Neurol Int       Date:  2017-09-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.