Literature DB >> 16498078

Fracture surface analysis of clinically failed fixed partial dentures.

B Taskonak1, J J Mecholsky, K J Anusavice.   

Abstract

Ceramic systems have limited long-term fracture resistance, especially when they are used in posterior areas or for fixed partial dentures. The objective of this study was to determine the site of crack initiation and the causes of fracture of clinically failed ceramic fixed partial dentures. Six Empress 2 lithia-disilicate (Li(2)O x 2SiO(2))-based veneered bridges and 7 experimental lithia-disilicate-based non-veneered ceramic bridges were retrieved and analyzed. Fractography and fracture mechanics methods were used to estimate the stresses at failure in 6 bridges (50%) whose fracture initiated from the occlusal surface of the connectors. Fracture of 1 non-veneered bridge (8%) initiated within the gingival surface of the connector. Three veneered bridges fractured within the veneer layers. Failure stresses of the all-core fixed partial dentures ranged from 107 to 161 MPa. Failure stresses of the veneered fixed partial dentures ranged from 19 to 68 MPa. We conclude that fracture initiation sites are controlled primarily by contact damage.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16498078      PMCID: PMC2242727          DOI: 10.1177/154405910608500314

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  8 in total

1.  A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic.

Authors:  J A Sorensen; M Cruz; W T Mito; O Raffeiner; H R Meredith; H P Foser
Journal:  Pract Periodontics Aesthet Dent       Date:  1999 Jan-Feb

2.  Influence of connector design on fracture probability of ceramic fixed-partial dentures.

Authors:  W Oh; N Götzen; K J Anusavice
Journal:  J Dent Res       Date:  2002-09       Impact factor: 6.116

3.  Role of investment interaction layer on strength and toughness of ceramic laminates.

Authors:  Burak Taskonak; Kenneth J Anusavice; John J Mecholsky
Journal:  Dent Mater       Date:  2004-10       Impact factor: 5.304

4.  Fractography: determining the sites of fracture initiation.

Authors:  J J Mecholsky
Journal:  Dent Mater       Date:  1995-03       Impact factor: 5.304

5.  A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics.

Authors:  W Höland; M Schweiger; M Frank; V Rheinberger
Journal:  J Biomed Mater Res       Date:  2000

6.  Residual stresses in bilayer dental ceramics.

Authors:  Burak Taskonak; John J Mecholsky; Kenneth J Anusavice
Journal:  Biomaterials       Date:  2005-06       Impact factor: 12.479

7.  Fracture-surface analysis of dental ceramics.

Authors:  J R Kelly; S D Campbell; H K Bowen
Journal:  J Prosthet Dent       Date:  1989-11       Impact factor: 3.426

8.  Fracture surface characterization of clinically failed all-ceramic crowns.

Authors:  J Y Thompson; K J Anusavice; A Naman; H F Morris
Journal:  J Dent Res       Date:  1994-12       Impact factor: 6.116

  8 in total
  10 in total

1.  Fractographic ceramic failure analysis using the replica technique.

Authors:  Susanne S Scherrer; Janet B Quinn; George D Quinn; H W Anselm Wiskott
Journal:  Dent Mater       Date:  2007-01-31       Impact factor: 5.304

2.  Finite element analysis to compare stress distribution of connector of lithia disilicate-reinforced glass-ceramic and zirconia-based fixed partial denture.

Authors:  Jie Lin; Akikazu Shinya; Harunori Gomi; Akiyoshi Shinya
Journal:  Odontology       Date:  2011-06-21       Impact factor: 2.634

3.  Fracture resistance of three-unit zirconia fixed partial denture with modified framework.

Authors:  Arthur Partiyan; Essam Osman; Mohammad M Rayyan; Moustafa Aboushelib; Ahmed Ibrahim; Ryo Jimbo
Journal:  Odontology       Date:  2016-04-15       Impact factor: 2.634

4.  Fractographic and Microhardness Evaluation of All-Ceramic Hot-Pressed and CAD/CAM Restorations after Hydrothermal Aging.

Authors:  Roxana Diana Vasiliu; Ion-Dragoș Uțu; Lucian Rusu; Adrian Boloș; Liliana Porojan
Journal:  Materials (Basel)       Date:  2022-06-03       Impact factor: 3.748

5.  Fractographic failure analysis of a Procera AllCeram crown using stereo and scanning electron microscopy.

Authors:  Susanne S Scherrer; George D Quinn; Janet B Quinn
Journal:  Dent Mater       Date:  2008-03-07       Impact factor: 5.304

6.  Edge chipping and flexural resistance of monolithic ceramics.

Authors:  Yu Zhang; James J-W Lee; Ramanathan Srikanth; Brian R Lawn
Journal:  Dent Mater       Date:  2013-10-17       Impact factor: 5.304

7.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2009-01-24       Impact factor: 3.573

8.  Biomechanical Response in Mandibular Bone due to Mastication Loading on 3-Unit Fixed Partial Dentures.

Authors:  Clarice Field; Qing Li; Wei Li; Michael Swain
Journal:  J Dent Biomech       Date:  2009-11-17

9.  Comparison of two fracture toughness testing methods using a glass-infiltrated and a zirconia dental ceramic.

Authors:  Premwara Triwatana; Phakphum Srinuan; Kallaya Suputtamongkol
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

Review 10.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.