Literature DB >> 21691716

Finite element analysis to compare stress distribution of connector of lithia disilicate-reinforced glass-ceramic and zirconia-based fixed partial denture.

Jie Lin1, Akikazu Shinya, Harunori Gomi, Akiyoshi Shinya.   

Abstract

This study used finite element method to analyze the stress distribution in connector of ceramic-based bilayer structures, in simulation of dental crown-like structures with a functional but weak veneer layer bonded onto a strong core layer. The purpose of this study was to evaluate the stress distribution at veneer/core interface of 2 different core materials [Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and lithia disilicate-reinforced glass-ceramic] using three-dimensional finite element analysis. Within the limitations of this study, finite element analysis showed that stress concentrations were located at the veneer/core interface of the connector in Y-TZP core models. The general observation was that compared with Y-TZP, lithia disilicate-reinforced glass-ceramic showed a relatively stable stress value and had a minor effect on the stress concentration susceptibility.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21691716     DOI: 10.1007/s10266-011-0025-2

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  11 in total

1.  Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures.

Authors:  Won-Suck Oh; Kenneth J Anusavice
Journal:  J Prosthet Dent       Date:  2002-05       Impact factor: 3.426

2.  Measurement of stress in mastication. I.

Authors:  D J ANDERSON
Journal:  J Dent Res       Date:  1956-10       Impact factor: 6.116

3.  Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures.

Authors:  Burak Taskonak; Atilla Sertgöz
Journal:  Dent Mater       Date:  2005-12-20       Impact factor: 5.304

4.  The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study.

Authors:  Ariel J Raigrodski; Gerard J Chiche; Narong Potiket; J L Hochstedler; Shawky E Mohamed; Susan Billiot; Donald E Mercante
Journal:  J Prosthet Dent       Date:  2006-10       Impact factor: 3.426

5.  Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling.

Authors:  J R Kelly; J A Tesk; J A Sorensen
Journal:  J Dent Res       Date:  1995-06       Impact factor: 6.116

6.  A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics.

Authors:  W Höland; M Schweiger; M Frank; V Rheinberger
Journal:  J Biomed Mater Res       Date:  2000

7.  Crack initiation modes in bilayered alumina/porcelain disks as a function of core/veneer thickness ratio and supporting substrate stiffness.

Authors:  N Wakabayashi; K J Anusavice
Journal:  J Dent Res       Date:  2000-06       Impact factor: 6.116

8.  Fractographic analyses of zirconia-based fixed partial dentures.

Authors:  Burak Taskonak; Jiahau Yan; John J Mecholsky; Atilla Sertgöz; Ayşe Koçak
Journal:  Dent Mater       Date:  2008-02-20       Impact factor: 5.304

9.  Fracture surface analysis of clinically failed fixed partial dentures.

Authors:  B Taskonak; J J Mecholsky; K J Anusavice
Journal:  J Dent Res       Date:  2006-03       Impact factor: 6.116

10.  Comparison of edge chipping resistance of PFM and veneered zirconia specimens.

Authors:  Janet B Quinn; Veeraraghavan Sundar; Edward E Parry; George D Quinn
Journal:  Dent Mater       Date:  2010-01       Impact factor: 5.304

View more
  3 in total

1.  Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Authors:  Jie Lin; Zhiqiang Zheng; Akikazu Shinya; Jukka Pekka Matinlinna; Michael George Botelho; Akiyoshi Shinya
Journal:  Odontology       Date:  2014-09-09       Impact factor: 2.634

2.  Effect of fiber post length and abutment height on fracture resistance of endodontically treated premolars prepared for zirconia crowns.

Authors:  Jie Lin; Jukka Pekka Matinlinna; Akikazu Shinya; Michael George Botelho; Zhiqiang Zheng
Journal:  Odontology       Date:  2017-12-14       Impact factor: 2.634

3.  Effect of different restorative crown design and materials on stress distribution in endodontically treated molars: a finite element analysis study.

Authors:  Jie Lin; Zhenxiang Lin; Zhiqiang Zheng
Journal:  BMC Oral Health       Date:  2020-08-18       Impact factor: 2.757

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.