Literature DB >> 27083582

Fracture resistance of three-unit zirconia fixed partial denture with modified framework.

Arthur Partiyan1, Essam Osman1, Mohammad M Rayyan1,2, Moustafa Aboushelib3, Ahmed Ibrahim4, Ryo Jimbo5.   

Abstract

Obtaining ideal prosthetic framework design is at times hindered by anatomical limitations in the posterior region that might increase the risk for zirconia restoration fracture. Modification such as increasing the bulk thickness especially in the connector region could result in strengthening the zirconia framework. Three-unit zirconia fixed partial dentures replacing mandibular molars were fabricated using the following two techniques: CAD/CAM technology and manual copy milling. Modified framework with unveneered full thickness connectors were designed and fabricated with the aforementioned methods. Conventional frameworks (0.5 mm thick with rounded 3 mm connectors) served as control (N = 20). After cementation on epoxy dies, the frameworks were loaded to fracture in a universal testing machine. Fractured surfaces were prepared for examination using scanning electron microscopy. Statistical analysis revealed significant differences in fracture resistance between conventional and modified framework design for both fabrication techniques tested. SEM examination indicated that critical crack originated at the tensile surface of the connectors for conventional frameworks. The critical crack for modified frameworks occurred on the axial wall of the abutments. The modification of the zirconia framework design presented significant improvement of the fracture resistance compared to the conventional design.

Entities:  

Keywords:  Connector morphology; Fracture resistance; Framework design; Zirconia

Mesh:

Substances:

Year:  2016        PMID: 27083582     DOI: 10.1007/s10266-016-0242-9

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  23 in total

1.  A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics.

Authors:  A Sundh; G Sjögren
Journal:  J Oral Rehabil       Date:  2004-07       Impact factor: 3.837

2.  Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling.

Authors:  Amélie K Mainjot; Gary S Schajer; Alain J Vanheusden; Michaël J Sadoun
Journal:  Dent Mater       Date:  2011-12-09       Impact factor: 5.304

3.  Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering.

Authors:  Anders Sundh; Göran Sjögren
Journal:  Dent Mater       Date:  2006-01-18       Impact factor: 5.304

4.  Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks.

Authors:  Philipp Kohorst; Timo J Herzog; Lothar Borchers; Meike Stiesch-Scholz
Journal:  Eur J Oral Sci       Date:  2007-04       Impact factor: 2.612

5.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.

Authors:  Irena Sailer; Aurel Fehér; Frank Filser; Ludwig J Gauckler; Heinz Lüthy; Christoph Hans Franz Hämmerle
Journal:  Int J Prosthodont       Date:  2007 Jul-Aug       Impact factor: 1.681

6.  Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results.

Authors:  Joachim Tinschert; Karen A Schulze; Gerd Natt; Peter Latzke; Nicole Heussen; Hubertus Spiekermann
Journal:  Int J Prosthodont       Date:  2008 May-Jun       Impact factor: 1.681

7.  Three-dimensional fit of CAD/CAM-made zirconia copings.

Authors:  Ovidiu Moldovan; Ralph G Luthardt; Nicoleta Corcodel; Heike Rudolph
Journal:  Dent Mater       Date:  2011-10-07       Impact factor: 5.304

8.  Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study.

Authors:  J Tinschert; G Natt; W Mautsch; M Augthun; H Spiekermann
Journal:  Int J Prosthodont       Date:  2001 May-Jun       Impact factor: 1.681

Review 9.  Clinical trials in zirconia: a systematic review.

Authors:  B Al-Amleh; K Lyons; M Swain
Journal:  J Oral Rehabil       Date:  2010-04-09       Impact factor: 3.837

10.  All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses.

Authors:  Andréa Barreira Motta; Luiz Carlos Pereira; Andréia R C C da Cunha
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

View more
  1 in total

1.  A Novel Design Modification to Improve Flexural Strength of Zirconia Framework: A Comparative Experimental In Vitro Study.

Authors:  Rajesh Shetty; Shifa Shoukath; Naresh H G Shetty; Sanath K Shetty; Savita Dandekeri; Mallikarjuna Ragher
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.