Literature DB >> 17270267

Fractographic ceramic failure analysis using the replica technique.

Susanne S Scherrer1, Janet B Quinn, George D Quinn, H W Anselm Wiskott.   

Abstract

OBJECTIVES: To demonstrate the effectiveness of in vivo replicas of fractured ceramic surfaces for descriptive fractography as applied to the analysis of clinical failures.
METHODS: The fracture surface topography of partially failed veneering ceramic of a Procera Alumina molar and an In-Ceram Zirconia premolar were examined utilizing gold-coated epoxy poured replicas viewed using scanning electron microscopy. The replicas were inspected for fractographic features such as hackle, wake hackle, twist hackle, compression curl and arrest lines for determination of the direction of crack propagation and location of the origin.
RESULTS: For both veneering ceramics, replicas provided an excellent reproduction of the fractured surfaces. Fine details including all characteristic fracture features produced by the interaction of the advancing crack with the material's microstructure could be recognized. The observed features are indicators of the local direction of crack propagation and were used to trace the crack's progression back to its initial starting zone (the origin). Drawbacks of replicas such as artifacts (air bubbles) or imperfections resulting from inadequate epoxy pouring were noted but not critical for the overall analysis of the fractured surfaces. SIGNIFICANCE: The replica technique proved to be easy to use and allowed an excellent reproduction of failed ceramic surfaces. It should be applied before attempting to remove any failed part remaining in situ as the fracture surface may be damaged during this procedure. These two case studies are intended as an introduction for the clinical researcher in using qualitative (descriptive) fractography as a tool for understanding fracture processes in brittle restorative materials and, secondarily, to draw conclusions as to possible design inadequacies in failed restorations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17270267      PMCID: PMC2077838          DOI: 10.1016/j.dental.2006.12.002

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Fractographic analyses of three ceramic whole crown restoration failures.

Authors:  Janet B Quinn; George D Quinn; J Robert Kelly; Susanne S Scherrer
Journal:  Dent Mater       Date:  2005-10       Impact factor: 5.304

2.  Failure analysis of ceramic clinical cases using qualitative fractography.

Authors:  Susanne S Scherrer; Janet B Quinn; George D Quinn; J Robert Kelly
Journal:  Int J Prosthodont       Date:  2006 Mar-Apr       Impact factor: 1.681

3.  Fracture surface analysis of dental ceramics: clinically failed restorations.

Authors:  J R Kelly; R Giordano; R Pober; M J Cima
Journal:  Int J Prosthodont       Date:  1990 Sep-Oct       Impact factor: 1.681

4.  Fracture-surface analysis of dental ceramics.

Authors:  J R Kelly; S D Campbell; H K Bowen
Journal:  J Prosthet Dent       Date:  1989-11       Impact factor: 3.426

5.  Fracture surface analysis of clinically failed fixed partial dentures.

Authors:  B Taskonak; J J Mecholsky; K J Anusavice
Journal:  J Dent Res       Date:  2006-03       Impact factor: 6.116

6.  Fracture surface characterization of clinically failed all-ceramic crowns.

Authors:  J Y Thompson; K J Anusavice; A Naman; H F Morris
Journal:  J Dent Res       Date:  1994-12       Impact factor: 6.116

  6 in total
  17 in total

Review 1.  Recent advances in materials for all-ceramic restorations.

Authors:  Jason A Griggs
Journal:  Dent Clin North Am       Date:  2007-07

2.  Accuracy and precision of fractal dimension measured on model surfaces.

Authors:  Timothy B McMurphy; Christopher A Harris; Jason A Griggs
Journal:  Dent Mater       Date:  2013-12-30       Impact factor: 5.304

3.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

Review 4.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

5.  Using fractal geometry to examine failed implants and prostheses.

Authors:  Jason A Griggs
Journal:  Dent Mater       Date:  2018-09-24       Impact factor: 5.304

6.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

7.  The progressive wear and abrasiveness of novel graded glass/zirconia materials relative to their dental ceramic counterparts.

Authors:  Marina R Kaizer; Rafael R Moraes; Sergio S Cava; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

8.  Three- to nine-year survival estimates and fracture mechanisms of zirconia- and alumina-based restorations using standardized criteria to distinguish the severity of ceramic fractures.

Authors:  Osvaldo D Moráguez; H W Anselm Wiskott; Susanne S Scherrer
Journal:  Clin Oral Investig       Date:  2015-05-20       Impact factor: 3.573

9.  A fractographic study of clinically retrieved zirconia-ceramic and metal-ceramic fixed dental prostheses.

Authors:  Zhen Pang; Asima Chughtai; Irena Sailer; Yu Zhang
Journal:  Dent Mater       Date:  2015-07-29       Impact factor: 5.304

10.  Fractographic failure analysis of a Procera AllCeram crown using stereo and scanning electron microscopy.

Authors:  Susanne S Scherrer; George D Quinn; Janet B Quinn
Journal:  Dent Mater       Date:  2008-03-07       Impact factor: 5.304

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.