Literature DB >> 12202644

Influence of connector design on fracture probability of ceramic fixed-partial dentures.

W Oh1, N Götzen, K J Anusavice.   

Abstract

Fracture of ceramic fixed-partial dentures (FPDs) tends to occur in the connector area because of stress concentrations. The objective of this study was to test the hypothesis that the radius of curvature at the gingival embrasure of the FPD connector significantly affects the fracture resistance of three-unit FPDs. Two three-dimensional finite element models (FEMs), representing two FPD connector designs, were created in a manner corresponding to that described in a previous experimental study (Oh, 2002). We performed fractographic analysis and FEM analyses based on CARES (NASA) post-processing software to determine the crack initiation site as well as to predict the characteristic strength, the location of peak stress concentrations, and the risk-of-rupture intensities. A good correlation was found between the experimentally measured failure loads and those predicted by FEM simulation analyses. Fractography revealed fracture initiation at the gingival embrasure, which confirms the numerically predicted fracture initiation site. For the designs tested, the radius of curvature at the gingival embrasure strongly affects the fracture resistance of FPDs.

Entities:  

Mesh:

Year:  2002        PMID: 12202644     DOI: 10.1177/154405910208100909

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  18 in total

1.  Fracture load of three-unit full-contour fixed dental prostheses fabricated with subtractive and additive CAD/CAM technology.

Authors:  Moritz Zimmermann; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2019-07-08       Impact factor: 3.573

2.  Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

Authors:  G Sannino; A Pozzi; R Schiavetti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

3.  Prosthodontic rehabilitation of a patient with aggressive periodontitis.

Authors:  David Livingstone; Varsha Murthy; Vineela Katam Reddy; Ajay Pillai
Journal:  BMJ Case Rep       Date:  2015-03-05

4.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

5.  Fracture surface analysis of clinically failed fixed partial dentures.

Authors:  B Taskonak; J J Mecholsky; K J Anusavice
Journal:  J Dent Res       Date:  2006-03       Impact factor: 6.116

6.  Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

Authors:  Josephine F Esquivel-Upshaw; Arthur E Clark; Jonathan J Shuster; Kenneth J Anusavice
Journal:  J Prosthodont       Date:  2013-06-12       Impact factor: 2.752

7.  Influence of heat treatment and veneering on the storage modulus and surface of zirconia ceramic.

Authors:  Georgius Siavikis; Michael Behr; Jef M van der Zel; Albert J Feilzer; Martin Rosentritt
Journal:  Eur J Dent       Date:  2011-04

8.  Biomechanical Response in Mandibular Bone due to Mastication Loading on 3-Unit Fixed Partial Dentures.

Authors:  Clarice Field; Qing Li; Wei Li; Michael Swain
Journal:  J Dent Biomech       Date:  2009-11-17

9.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11

10.  All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses.

Authors:  Andréa Barreira Motta; Luiz Carlos Pereira; Andréia R C C da Cunha
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.