Literature DB >> 19169719

Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Florian Beuer1, Daniel Edelhoff, Wolfgang Gernet, John A Sorensen.   

Abstract

This clinical study evaluated posterior three-unit fixed dental prostheses (FDPs) made of zirconia substructures veneered with pressable glass-ceramic. Nineteen patients received 21 FDPs replacing either the second premolar, first molar, or second molar. The FDPs were cemented with glass ionomer. Recall examinations were performed every 12 months. The mean service time of the FDP was 40 months. At 30 months, one maxillary FDP exhibited zirconia framework fracture at a thinned occlusal area of the abutment. Loss of retention led to the removal of one FDP after 38 months. The Kaplan-Meier survival probability was 90.5% after 40 months for all types of failures and 95.2% concerning framework fractures. The overpressing technique appears to be reliable in terms of the veneering material. However, one framework fracture was observed in this study.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19169719     DOI: 10.1007/s00784-009-0249-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  42 in total

1.  PERIODONTAL DISEASE IN PREGNANCY. II. CORRELATION BETWEEN ORAL HYGIENE AND PERIODONTAL CONDTION.

Authors:  J SILNESS; H LOE
Journal:  Acta Odontol Scand       Date:  1964-02       Impact factor: 2.331

Review 2.  DYNAMICS OF SUPRAGINGIVAL CALCULUS FORMATION.

Authors:  H R MUEHLEMANN; H E SCHROEDER
Journal:  Adv Oral Biol       Date:  1964

3.  All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study.

Authors:  P Vult von Steyern; P Carlson; K Nilner
Journal:  J Oral Rehabil       Date:  2005-03       Impact factor: 3.837

4.  Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques.

Authors:  Siegbert Witkowski; Futoshi Komine; Thomas Gerds
Journal:  J Prosthet Dent       Date:  2006-07       Impact factor: 3.426

5.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.

Authors:  Irena Sailer; Aurel Fehér; Frank Filser; Ludwig J Gauckler; Heinz Lüthy; Christoph Hans Franz Hämmerle
Journal:  Int J Prosthodont       Date:  2007 Jul-Aug       Impact factor: 1.681

6.  Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results.

Authors:  Joachim Tinschert; Karen A Schulze; Gerd Natt; Peter Latzke; Nicole Heussen; Hubertus Spiekermann
Journal:  Int J Prosthodont       Date:  2008 May-Jun       Impact factor: 1.681

7.  Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics.

Authors:  J Tinschert; D Zwez; R Marx; K J Anusavice
Journal:  J Dent       Date:  2000-09       Impact factor: 4.379

8.  A long-term retrospective and clinical follow-up study of In-Ceram Alumina FPDs.

Authors:  Karl-Gustaf Olsson; Björn Fürst; Bernt Andersson; Gunnar E Carlsson
Journal:  Int J Prosthodont       Date:  2003 Mar-Apr       Impact factor: 1.681

9.  Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials.

Authors:  Florian Beuer; Bastian Steff; Michael Naumann; John A Sorensen
Journal:  Eur J Oral Sci       Date:  2008-08       Impact factor: 2.612

10.  Fatigue and fracture properties of yttria partially stabilized zirconia crown systems.

Authors:  Eleftheria Tsalouchou; Mike J Cattell; Jonathan C Knowles; Piyapanna Pittayachawan; Ailbhe McDonald
Journal:  Dent Mater       Date:  2007-08-06       Impact factor: 5.304

View more
  33 in total

1.  Shear bond strength between an indirect composite layering material and feldspathic porcelain-coated zirconia ceramics.

Authors:  Ryosuke Fushiki; Futoshi Komine; Markus B Blatz; Mai Koizuka; Kohei Taguchi; Hideo Matsumura
Journal:  Clin Oral Investig       Date:  2011-12-06       Impact factor: 3.573

2.  Modified Y-TZP core design improves all-ceramic crown reliability.

Authors:  N R F A Silva; E A Bonfante; B T Rafferty; R A Zavanelli; E D Rekow; V P Thompson; P G Coelho
Journal:  J Dent Res       Date:  2010-11-05       Impact factor: 6.116

3.  Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures.

Authors:  Martin Rosentritt; Carola Kolbeck; Gerhard Handel; Sibylle Schneider-Feyrer; Michael Behr
Journal:  Clin Oral Investig       Date:  2010-10-05       Impact factor: 3.573

4.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

5.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

6.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

7.  Risk factors for technical and biological complications with zirconia single crowns.

Authors:  Sven Rinke; Katharina Lange; Matthias Roediger; Nikolaus Gersdorff
Journal:  Clin Oral Investig       Date:  2015-02-07       Impact factor: 3.573

8.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

9.  Clinical outcomes of zirconia-based implant- and tooth-supported single crowns.

Authors:  Farahnaz Nejatidanesh; Hedayat Moradpoor; Omid Savabi
Journal:  Clin Oral Investig       Date:  2015-04-25       Impact factor: 3.573

10.  Comparison of fracture toughness of all-ceramic and metal-ceramic cement retained implant crowns: an in vitro study.

Authors:  S Rao; R Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-01-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.