Literature DB >> 16376255

Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips.

Anthony S Unger1, Randall J Lewis, Thomas Gruen.   

Abstract

Long-term survival of the acetabular component in revision total hip arthroplasty (THA) is determined by initial implant stability and bone ingrowth. Highly porous Trabecular Metal (TM, Zimmer, Inc, Warsaw, Ind) facilitates ingrowth and may be an ideal material for revision THA. The outcome and survivorship of a TM, nonmodular, uncemented acetabular cup were assessed in 60 consecutive patients undergoing revision THA (mean follow-up, 42 months; range, 14-68 months). Most (55/60) acetabular cups were implanted without screw fixation. Mean Harris Hips Scores improved from 74.8 preoperatively to 94.4 at last follow-up. Serial radiographs demonstrated excellent bone apposition and bone graft incorporation. Complications were limited to 7 cases of dislocation and 1 revision for aseptic loosening. The TM acetabular cup appears suitable for use in revision THA and warrants further study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16376255     DOI: 10.1016/j.arth.2005.01.023

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  42 in total

1.  [Mega cups and partial pelvic replacement].

Authors:  R von Eisenhart-Rothe; H Gollwitzer; A Toepfer; H Pilge; B M Holzapfel; H Rechl; R Gradinger
Journal:  Orthopade       Date:  2010-10       Impact factor: 1.087

2.  Long-term results for minor column allografts in revision hip arthroplasty.

Authors:  Paul T H Lee; Guy Raz; Oleg A Safir; David J Backstein; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Uncemented Porous Tantalum Acetabular Components: Early Follow-Up and Failures in 599 Revision Total Hip Arthroplasties.

Authors:  William J Long; Nicolas O Noiseux; Tad M Mabry; Arlen D Hanssen; David G Lewallen
Journal:  Iowa Orthop J       Date:  2015

4.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

5.  Acetabular cage survival and analysis of factors related to failure.

Authors:  Jonathan N Sembrano; Edward Y Cheng
Journal:  Clin Orthop Relat Res       Date:  2008-02-26       Impact factor: 4.176

6.  Type III acetabular defect revision with bilobed components: five-year results.

Authors:  Joseph T Moskal; Michael E Higgins; Joseph Shen
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

7.  Trabecular Metal cups for acetabular defects with 50% or less host bone contact.

Authors:  Dror Lakstein; David Backstein; Oleg Safir; Yona Kosashvili; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

8.  Why revision total hip arthroplasty fails.

Authors:  Bryan D Springer; Thomas K Fehring; William L Griffin; Susan M Odum; John L Masonis
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

Review 9.  Systematic review on outcomes of acetabular revisions with highly-porous metals.

Authors:  Samik Banerjee; Kimona Issa; Bhaveen H Kapadia; Robert Pivec; Harpal S Khanuja; Michael A Mont
Journal:  Int Orthop       Date:  2013-11-01       Impact factor: 3.075

10.  Tantalum components in difficult acetabular revisions.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2009-07-07       Impact factor: 4.176

View more