Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

H Yoshida1, A Faust, J Wilckens, M Kitagawa, J Fetto, Edmund Y-S Chao.   

Abstract

Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.

Entities:  

Mesh:

Year:  2005        PMID: 16120442     DOI: 10.1016/j.jbiomech.2005.06.026

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  43 in total

1.  Effects of idealized joint geometry on finite element predictions of cartilage contact stresses in the hip.

Authors:  Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Jeffrey A Weiss
Journal:  J Biomech       Date:  2010-02-21       Impact factor: 2.712

2.  Validation of finite element predictions of cartilage contact pressure in the human hip joint.

Authors:  Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Christopher L Peters; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

3.  Normal and osteoarthritic hip joint mechanical behaviour: a comparison study.

Authors:  A Pustoc'h; L Cheze
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

4.  Regional variations of bone quantity and quality impact femoral head collapse.

Authors:  Christian J Zaino; Alex Leali; Joseph F Fetto
Journal:  Clin Orthop Relat Res       Date:  2009-08-26       Impact factor: 4.176

5.  Evaluation of a computerized measurement technique for joint alignment before and during periacetabular osteotomy.

Authors:  Robert S Armiger; Mehran Armand; Jyri Lepisto; Davneet Minhas; Kaj Tallroth; Simon C Mears; Matthew D Waites; Russell H Taylor
Journal:  Comput Aided Surg       Date:  2007-07

Review 6.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

7.  Finite element prediction of cartilage contact stresses in normal human hips.

Authors:  Michael D Harris; Andrew E Anderson; Corinne R Henak; Benjamin J Ellis; Christopher L Peters; Jeffrey A Weiss
Journal:  J Orthop Res       Date:  2011-12-30       Impact factor: 3.494

8.  Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.

Authors:  R Nithyaprakash; S Shankar; M S Uddin
Journal:  Med Biol Eng Comput       Date:  2017-11-02       Impact factor: 2.602

9.  Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems.

Authors:  M T Mathew; M J Runa; M Laurent; J J Jacobs; L A Rocha; M A Wimmer
Journal:  Wear       Date:  2011-07-29       Impact factor: 3.892

10.  A new discrete element analysis method for predicting hip joint contact stresses.

Authors:  Christine L Abraham; Steve A Maas; Jeffrey A Weiss; Benjamin J Ellis; Christopher L Peters; Andrew E Anderson
Journal:  J Biomech       Date:  2013-03-01       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.