Literature DB >> 29094238

Computational wear assessment of hard on hard hip implants subject to physically demanding tasks.

R Nithyaprakash1, S Shankar2, M S Uddin3.   

Abstract

Hip implants subject to gait loading due to occupational activities are potentially prone to failures such as osteolysis and aseptic loosening, causing painful revision surgeries. Highly risky gait activities such as carrying a load, stairs up or down and ladder up or down may cause excessive loading at the hip joint, resulting in generation of wear and related debris. Estimation of wear under the above gait activities is thus crucial to design and develop a new and improved implant component. With this motivation, this paper presents an assessment of wear generation of PCD-on-PCD (poly crystalline diamond) hip implants using finite element (FE) analysis. Three-dimensional (3D) FE model of hip implant along with peak gait and peak flexion angle for each activity was used to estimate wear of PCD for 10 million cycles. The maximum and minimum initial contact pressures of 206.19 MPa and 151.89 MPa were obtained for carrying load of 40 kg and sitting down or getting up activity. The simulation results obtained from finite element model also revealed that the maximum linear wear of 0.585 μm occurred for the patients frequently involved in sitting down or getting up gait activity and maximum volumetric wear of 0.025 mm3 for ladder up gait activity. The stair down activity showed the least linear and volumetric wear of 0.158 μm and 0.008 mm3, respectively, at the end of 10 million cycles. Graphical abstract Computational wear assessment of hip implants subjected to physically demanding tasks.

Entities:  

Keywords:  Finite element analysis; Hip implants; Occupational activities; Wear

Mesh:

Year:  2017        PMID: 29094238     DOI: 10.1007/s11517-017-1739-2

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  21 in total

1.  The influence of the pelvic bone on the computational results of the acetabular component of a total hip prosthesis.

Authors:  Sara Barreto; João Folgado; Paulo R Fernandes; Jacinto Monteiro
Journal:  J Biomech Eng       Date:  2010-05       Impact factor: 2.097

2.  Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses.

Authors:  Feng Liu; Zhongmin Jin; P Roberts; P Grigoris
Journal:  Proc Inst Mech Eng H       Date:  2006-08       Impact factor: 1.617

3.  The Divergence of Wear Propagation and Stress at Steep Acetabular Cup Positions Using Ceramic Heads and Sequentially Cross-Linked Polyethylene Liners.

Authors:  Carmen Zietz; Christian Fabry; Felix Baum; Rainer Bader; Daniel Kluess
Journal:  J Arthroplasty       Date:  2015-02-28       Impact factor: 4.757

4.  Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.

Authors:  Mazen Al-Hajjar; John Fisher; Joanne L Tipper; Sophie Williams; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2013-02-08       Impact factor: 1.617

5.  Contact of dual mobility implants: effects of cup wear and inclination.

Authors:  M S Uddin
Journal:  Comput Methods Biomech Biomed Engin       Date:  2014-07-14       Impact factor: 1.763

Review 6.  Contributions of human tissue analysis to understanding the mechanisms of loosening and osteolysis in total hip replacement.

Authors:  Jiri Gallo; Jana Vaculova; Stuart B Goodman; Yrjö T Konttinen; Jacob P Thyssen
Journal:  Acta Biomater       Date:  2014-02-10       Impact factor: 8.947

7.  The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing.

Authors:  S J Mellon; Y-M Kwon; S Glyn-Jones; D W Murray; H S Gill
Journal:  Med Eng Phys       Date:  2011-06-25       Impact factor: 2.242

8.  Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 "HAP" PAUL Award.

Authors:  B Sonny Bal; Ashok Khandkar; R Lakshminarayanan; Ian Clarke; Aaron A Hoffman; Mohamed N Rahaman
Journal:  J Arthroplasty       Date:  2008-04-28       Impact factor: 4.757

9.  Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation.

Authors:  William L Walter; Gary C O'toole; William K Walter; Andrew Ellis; Bernard A Zicat
Journal:  J Arthroplasty       Date:  2007-03-28       Impact factor: 4.757

Review 10.  Tribology and total hip joint replacement: current concepts in mechanical simulation.

Authors:  S Affatato; M Spinelli; M Zavalloni; C Mazzega-Fabbro; M Viceconti
Journal:  Med Eng Phys       Date:  2008-09-06       Impact factor: 2.242

View more