Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: a comparison between two testing systems.

M T Mathew1, M J Runa, M Laurent, J J Jacobs, L A Rocha, M A Wimmer.   

Abstract

Metal-on-metal (MOM) hip prosthesis bearings have enjoyed renewed popularity, but concerns remain with wear debris and metal ion release causing a negative response in the surrounding tissues. Further understanding into the wear and corrosion mechanisms occurring in MOM hips is therefore essential.The purpose of this study was to evaluate the tribocorrosion behaviour, or interplay between corrosion and wear, of a low-carbon CoCrMo alloy as a function of loading. The tribocorrosion tests were performed using two tribometer configurations. In the first configuration, "System A", a linearly reciprocating alumina ball slid against the flat metal immersed in a phosphate buffer solution (PBS). In the second configuration, "System B", the flat end of a cylindrical metal pin was pressed against an alumina ball that oscillated rotationally, using bovine calf serum (BCS) as the lubricant and electrolyte. System B was custom-built to emulate in vivo conditions. The tribocorrosion tests were performed under potentiostatic conditions at -0.345V, with a sliding duration of 1800 seconds and a frequency of 1Hz. In System A the applied loads were 0.05, 0.5, and 1N (138, 296 and 373MPa, respectively) and in System B were 16, 32, and 64N (474, 597, and 752MPa, respectively). Electrochemical impedance spectroscopy (EIS) and polarization resistance were estimated. The total mass loss (K(wc)) in the CoCrMo was determined. The mass loss due to wear (K(w)) and that due to corrosion (K(c)) were determined. The dominant wear regime for the CoCrMo alloy subjected to sliding changes from wear-corrosion to mechanical wear as the contact stress increases. An attempt was made to compare both system, in their tribochemical responses and formulate some insights in the total degradation processes. Our results also suggest that the proteins in the serum lubricant assist in the generation of a protective layer against corrosion during sliding. The study highlights the need of adequate methodology/guidelines to compare the results from different test systems and translating in solving the practical problems.

Entities:  

Year:  2011        PMID: 21921971      PMCID: PMC3171172          DOI: 10.1016/j.wear.2011.01.086

Source DB:  PubMed          Journal:  Wear        ISSN: 0043-1648            Impact factor:   3.892


  8 in total

Review 1.  The biologic responses to orthopedic implants and their wear debris.

Authors:  E F DiCarlo; P G Bullough
Journal:  Clin Mater       Date:  1992

2.  Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation.

Authors:  R Büscher; G Täger; W Dudzinski; B Gleising; M A Wimmer; A Fischer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2005-01-15       Impact factor: 3.368

3.  Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

Authors:  H Yoshida; A Faust; J Wilckens; M Kitagawa; J Fetto; Edmund Y-S Chao
Journal:  J Biomech       Date:  2005-08-24       Impact factor: 2.712

Review 4.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

5.  Prevalence and most common causes of disability among adults--United States, 2005.

Authors: 
Journal:  MMWR Morb Mortal Wkly Rep       Date:  2009-05-01       Impact factor: 17.586

6.  Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.

Authors:  J J Jacobs; A K Skipor; L M Patterson; N J Hallab; W G Paprosky; J Black; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

7.  Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers.

Authors:  Markus A Wimmer; Alfons Fischer; Robin Büscher; Robin Pourzal; Christoph Sprecher; Roland Hauert; Joshua J Jacobs
Journal:  J Orthop Res       Date:  2010-04       Impact factor: 3.494

8.  Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles.

Authors:  P F Doorn; P A Campbell; J Worrall; P D Benya; H A McKellop; H C Amstutz
Journal:  J Biomed Mater Res       Date:  1998-10
  8 in total
  12 in total

1.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

2.  In Vitro Evidence for Cell-Accelerated Corrosion Within Modular Junctions of Total Hip Replacements.

Authors:  Divya Rani Bijukumar; Shruti Salunkhe; Dalton Morris; Abhijith Segu; Deborah J Hall; Robin Pourzal; Mathew T Mathew
Journal:  J Orthop Res       Date:  2019-09-01       Impact factor: 3.494

3.  The effect of contact load on CoCrMo wear and the formation and retention of tribofilms.

Authors:  M A Wimmer; M P Laurent; M T Mathew; C Nagelli; Y Liao; L D Marks; J J Jacobs; A Fischer
Journal:  Wear       Date:  2015 May-Jun       Impact factor: 3.892

4.  Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation.

Authors:  M T Mathew; C Nagelli; R Pourzal; A Fischer; M P Laurent; J J Jacobs; M A Wimmer
Journal:  J Mech Behav Biomed Mater       Date:  2013-09-03

5.  Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions.

Authors:  Robin Pourzal; Deborah J Hall; Jonas Ehrich; Stephanie M McCarthy; Mathew T Mathew; Joshua J Jacobs; Robert M Urban
Journal:  Clin Orthop Relat Res       Date:  2017-09-07       Impact factor: 4.176

6.  Differential toxicity of processed and non-processed states of CoCrMo degradation products generated from a hip simulator on neural cells.

Authors:  Divya Rani Bijukumar; Abhijith Segu; YongChao Mou; Reza Ghodsi; Tolou Shokufhar; Mark Barba; Xue-Jun Li; Mathew Thoppil Mathew
Journal:  Nanotoxicology       Date:  2018-09-25       Impact factor: 5.913

7.  Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins.

Authors:  Mathew T Mathew; Joshua J Jacobs; Markus A Wimmer
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

9.  Non-invasive early detection of failure modes in total hip replacements (THR) via acoustic emission (AE).

Authors:  Christine Lee; Lu Zhang; Dalton Morris; Kai Yuan Cheng; Remya Ampadi Ramachandran; Mark Barba; Divya Bijukumar; Didem Ozevin; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-19

10.  Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.

Authors:  Dmitry Royhman; Robin Pourzal; Deborah Hall; Hannah J Lundberg; Markus A Wimmer; Joshua Jacobs; Nadim J Hallab; Mathew T Mathew
Journal:  J Mech Behav Biomed Mater       Date:  2021-03-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.