Literature DB >> 19214612

Normal and osteoarthritic hip joint mechanical behaviour: a comparison study.

A Pustoc'h1, L Cheze.   

Abstract

The assessment of contact areas within the hip joint during activities of daily living is of critical importance to understand why degeneration mechanisms are sometimes initiated. A generic finite element model is developed and constrained with experimental personalized conditions to locate contact areas and determine pressure distribution, both during walking and stair climbing. Bony structures are positioned in relation to each other by using experimental kinematical data. Implemented loading conditions are computed from an inverse dynamic approach coupled with an optimization method. The mechanical behaviour of a healthy hip joint is first simulated. This model is then used as a reference for the evaluation of a pathological mechanical behaviour. Thus, experimental data are collected for a patient presenting a coxarthrosis. The comparison of the pathological and normal behaviours emphasizes that the contact area swept within the osteoarthritic hip joint is limited both during walking and stair climbing.

Entities:  

Mesh:

Year:  2009        PMID: 19214612     DOI: 10.1007/s11517-009-0457-9

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  38 in total

1.  A three-dimensional kinematic and dynamic study of the lower limb during the stance phase of gait using an homogeneous matrix approach.

Authors:  Nathalie Doriot; Laurence Chèze
Journal:  IEEE Trans Biomed Eng       Date:  2004-01       Impact factor: 4.538

2.  A new method to investigate in vivo knee behavior using a finite element model of the lower limb.

Authors:  P Beillas; G Papaioannou; S Tashman; K H Yang
Journal:  J Biomech       Date:  2004-07       Impact factor: 2.712

3.  Detection of non-standard EMG profiles in walking.

Authors:  A L Hof; H Elzinga; W Grimmius; J P K Halbertsma
Journal:  Gait Posture       Date:  2005-02       Impact factor: 2.840

4.  The influence of the acetabular labrum on hip joint cartilage consolidation: a poroelastic finite element model.

Authors:  S J Ferguson; J T Bryant; R Ganz; K Ito
Journal:  J Biomech       Date:  2000-08       Impact factor: 2.712

5.  The three-dimensional determination of internal loads in the lower extremity.

Authors:  U Glitsch; W Baumann
Journal:  J Biomech       Date:  1997 Nov-Dec       Impact factor: 2.712

6.  Hip contact forces and gait patterns from routine activities.

Authors:  G Bergmann; G Deuretzbacher; M Heller; F Graichen; A Rohlmann; J Strauss; G N Duda
Journal:  J Biomech       Date:  2001-07       Impact factor: 2.712

7.  The sensitivity of muscle force predictions to changes in physiologic cross-sectional area.

Authors:  R A Brand; D R Pedersen; J A Friederich
Journal:  J Biomech       Date:  1986       Impact factor: 2.712

8.  Biphasic creep and stress relaxation of articular cartilage in compression? Theory and experiments.

Authors:  V C Mow; S C Kuei; W M Lai; C G Armstrong
Journal:  J Biomech Eng       Date:  1980-02       Impact factor: 2.097

9.  [Functional gait adaptations in patients with painful hip].

Authors:  C Hulet; D E Hurwitz; T P Andriacchi; J O Galante; C Vielpeau
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2000-10

10.  Modelling cartilage mechanobiology.

Authors:  Dennis R Carter; Marcy Wong
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2003-09-29       Impact factor: 6.237

View more
  1 in total

Review 1.  Biomechanical analysis of the effects of medial meniscectomy on degenerative osteoarthritis.

Authors:  Ji Yong Bae; Kyung Soon Park; Jong Keun Seon; Dai Soon Kwak; Insu Jeon; Eun Kyoo Song
Journal:  Med Biol Eng Comput       Date:  2011-10-26       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.