Literature DB >> 15666136

[Pathological findings in tissue surrounding revised metal/metal articulations].

W Baur1, W Hönle, H-G Willert, A Schuh.   

Abstract

INTRODUCTION: The aim of the current study was to elucidate the incidence of allergic reactions to metal/metal articulations in revised total hip arthroplasties.
MATERIALS AND METHODS: Between 1 January 1997 and 31 January 2002 a consecutive series of tissue samples from 13 revised total hip arthroplasties with metal/metal articulations were histopathologically examined for signs of delayed type hypersensitivity (DTH). Mean age at the time of revision of the eight women and five men was 58.7 years. The prostheses were revised after a mean follow-up of 45 months. Indications for revision were progressive osteolysis of the proximal femur in 12 cases and instability in one case. All patients were clinically and radiologically evaluated after a mean follow-up of 52 months (min. 22, max. 74) after revision.
RESULTS: No signs of infection were found in either histopathological or microbiological examinations. In ten cases, perivascular lymphocytic infiltrates could be found as a sign of DTH. After revision and changing of the articulation all osteolyses healed.
CONCLUSION: In 10/13 cases (76.9%) signs of DTH could be detected. The fact that all osteolyses healed after changing the articulation may give a strong hint that there is an immunological contribution to this radiological changes. Metal/metal articulations cannot be recommended as the optimum implant for young patients, as the number of patients with allergic reactions to nickel, chrome or cobalt is increasing continuously.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15666136     DOI: 10.1007/s00132-004-0761-x

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  53 in total

1.  Zweymueller with metal-on-metal articulation: clinical, radiological and histological analysis of short-term results.

Authors:  Panagiotis Korovessis; Georgios Petsinis; Maria Repanti
Journal:  Arch Orthop Trauma Surg       Date:  2002-12-19       Impact factor: 3.067

2.  Increased blood cobalt and chromium after total hip replacement.

Authors:  A W Schaffer; A Pilger; C Engelhardt; K Zweymueller; H W Ruediger
Journal:  J Toxicol Clin Toxicol       Date:  1999

3.  Long-term results after implantation of McKee-Farrar total hip prostheses.

Authors:  S Jantsch; W Schwägerl; P Zenz; M Semlitsch; W Fertschak
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

4.  Urticaria after insertion of Smith-Petersen Vitallium nail.

Authors:  A W McKenzie; C V Aitken; R Ridsdill-Smith
Journal:  Br Med J       Date:  1967-10-07

5.  In vivo wear of three types of metal on metal hip prostheses during two decades of use.

Authors:  H McKellop; S H Park; R Chiesa; P Doorn; B Lu; P Normand; P Grigoris; H Amstutz
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Prevalence of contact allergy by sex, race and age.

Authors:  C L Goh
Journal:  Contact Dermatitis       Date:  1986-04       Impact factor: 6.600

7.  New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal.

Authors:  M Semlitsch; M Lehmann; H Weber; E Doerre; H G Willert
Journal:  J Biomed Mater Res       Date:  1977-07

Review 8.  Distribution of cobalt chromium wear and corrosion products and biologic reactions.

Authors:  K Merritt; S A Brown
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

9.  An unusual reaction in muscle in association with Vitallium plate: a report of possible metal hypersensitivity.

Authors:  D S Halpin
Journal:  J Bone Joint Surg Br       Date:  1975-11

Review 10.  Metal sensitivities and orthopaedic implants revisited: the potential for metal allergy with the new metal-on-metal joint prostheses.

Authors:  D J Gawkrodger
Journal:  Br J Dermatol       Date:  2003-06       Impact factor: 9.302

View more
  14 in total

1.  The influence of the centre of rotation on implant survival using a modular stem hip prosthesis.

Authors:  Francesco Traina; Marcello De Fine; Federico Biondi; Enrico Tassinari; Andrea Galvani; Aldo Toni
Journal:  Int Orthop       Date:  2008-12-20       Impact factor: 3.075

2.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

3.  [Allergy diagnostics in suspected metal implant intolerance].

Authors:  P Thomas; B Summer; V Krenn; M Thomsen
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

4.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

5.  [Different symptoms in patients with prostheses with metal-metal bearings].

Authors:  M Thomsen; J P Kretzer; V Krenn; P Thomas
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

Review 6.  Strategies for head and inlay exchange in revision hip arthroplasty.

Authors:  Martin Pospischill; Karl Knahr
Journal:  Int Orthop       Date:  2010-11-19       Impact factor: 3.075

7.  [Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German association of orthopedics and orthopedic surgery), DKG (German contact dermatitis research group) and dgaki (German society for allergology and clinical immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Orthopade       Date:  2008-01       Impact factor: 1.087

8.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

9.  [Biodegradable synthetic implant materials : clinical applications and immunological aspects].

Authors:  F Witte; T Calliess; H Windhagen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

10.  [Allergy diagnostics in implant intolerance].

Authors:  P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.