In vivo wear of three types of metal on metal hip prostheses during two decades of use.

H McKellop1, S H Park, R Chiesa, P Doorn, B Lu, P Normand, P Grigoris, H Amstutz.   

Abstract

Wear was analyzed on 21 metal on metal hip replacements, including McKee-Farrar, Müller, and Ring, that were retrieved from patients after as many as 25 years. Light and scanning electron microscopy indicated that early wear included substantial third body abrasion, possibly from particles generated while scratches from the original polishing were being eradicated and from dislodged surface carbides. However, the main contact zones were eventually worn smoother than the original surfaces. Wear was quantified by digitizing the shapes of the components on a coordinate measuring machine and identifying those areas that deviated from the original spheric surface. On the femoral heads, wear was typically concentrated in the superomedial region, that is, on the load axis. Three cases also had substantial wear inferiorly, but there were no cases with circumferential (equatorial) wear. The long term wear rates averaged approximately 6 micrometers per year or less and produced an average of approximately 6 mm3 of metallic wear debris per year or less. Wear rate tended to increase as clearance increased over the range of 127 to 386 micrometers, and a McKee-Farrar prosthesis with the extreme clearance of 1.7 mm wore approximately 16 times faster than the average, but there was no apparent relationship between clearance and time to revision. Larger McKee-Farrar balls had less volumetric wear, on average, than smaller balls, and the Müller balls had the greatest wear, which may have been due to contact with the edges of recesses machined into the bearing zones of the Müller cups.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8769330     DOI: 10.1097/00003086-199608001-00013

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Cup loosening after cemented Metasul® total hip replacement: a retrieval analysis.

Authors:  Christophe Nich; Moussa Hamadouche
Journal:  Int Orthop       Date:  2010-06-11       Impact factor: 3.075

2.  [Reasons for failure of hip resurfacing implants. A failure analysis based on 250 revision specimens].

Authors:  M M Morlock; N Bishop; F Stahmer; J Zustin; G Sauter; M Hahn; M Krause; W Rüther; M Amling
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

3.  Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy.

Authors:  Shane A Catledge; Rishi Vaid; Patrick Diggins; Jeffrey J Weimer; Mark Koopman; Yogesh K Vohra
Journal:  J Mater Sci Mater Med       Date:  2011-01-08       Impact factor: 3.896

Review 4.  The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

Authors:  William T Long
Journal:  Iowa Orthop J       Date:  2005

5.  In vitro studies on the effect of particle size on macrophage responses to nanodiamond wear debris.

Authors:  Vinoy Thomas; Brian A Halloran; Namasivayam Ambalavanan; Shane A Catledge; Yogesh K Vohra
Journal:  Acta Biomater       Date:  2012-02-02       Impact factor: 8.947

6.  Wear of surface engineered metal-on-metal hip prostheses.

Authors:  J Fisher; X Q Hu; T D Stewart; S Williams; J L Tipper; E Ingham; M H Stone; C Davies; P Hatto; J Bolton; M Riley; C Hardaker; G H Isaac; G Berry
Journal:  J Mater Sci Mater Med       Date:  2004-03       Impact factor: 3.896

Review 7.  [Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].

Authors:  M M Morlock; M Jäger
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

8.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

9.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Patients report improvement in quality of life and satisfaction after hip resurfacing arthroplasty.

Authors:  Wael A Rahman; Nelson V Greidanus; Alexander Siegmeth; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.