Literature DB >> 20204719

[Implant allergies].

P Thomas1, M Thomsen.   

Abstract

An increasing number of patients receive and benefit from osteosynthesis materials or artificial joint replacement. The most common complications are mechanical problems or infection. Metals like nickel, chromium and cobalt as well as bone cement components like acrylates and gentamicin are potential contact allergens which can cause intolerance reactions to implants. Eczema, delayed wound/bone healing, recurrent effusions, pain and implant loosening all have been described as manifestation of implant allergy. In contrast to the high incidence of cutaneous metal allergy, allergies associated with implants are rare. Diagnosis of metal implant allergy is still difficult. Thus differential diagnoses--in particular infection--have to be excluded and a combined approach of allergologic diagnostics by patch test and histopathology of peri-implant tissue is recommended. It is still unknown which conditions induce allergic sensitization to implants or trigger peri-implant allergic reactions in the case of preexisting cutaneous metal allergy. Despite the risk of developing complications being unclear, titanium based osteosynthesis materials are recommended for metal allergic patients and the use of metal-metal couplings in arthroplasty is not recommended for such patients. If the regular CoCr-polyethylene articulation is employed, the patient should give informed written consent.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20204719     DOI: 10.1007/s00105-009-1907-x

Source DB:  PubMed          Journal:  Hautarzt        ISSN: 0017-8470            Impact factor:   0.751


  47 in total

1.  Allergic contact dermatitis and osteomyelitis due to sternal stainless steel wire.

Authors:  K Hayashi; H Kaneko; S Kawachi; T Saida
Journal:  Contact Dermatitis       Date:  1999-08       Impact factor: 6.600

2.  Urticaria after insertion of Smith-Petersen Vitallium nail.

Authors:  A W McKenzie; C V Aitken; R Ridsdill-Smith
Journal:  Br Med J       Date:  1967-10-07

Review 3.  Periprosthetic osteolysis: an immunologist's update.

Authors:  R John Looney; Edward M Schwarz; Allen Boyd; Regis J O'Keefe
Journal:  Curr Opin Rheumatol       Date:  2006-01       Impact factor: 5.006

4.  [Metallurgical differentiation of cobalt-chromium alloys for implants].

Authors:  U Holzwarth; P Thomas; W Kachler; J Göske; A Schuh
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

Review 5.  Distribution of cobalt chromium wear and corrosion products and biologic reactions.

Authors:  K Merritt; S A Brown
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

6.  Failure of metal-on-metal total hip arthroplasty mimicking hip infection. A report of two cases.

Authors:  Mark M Mikhael; Arlen D Hanssen; Rafael J Sierra
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

7.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

8.  Cutaneous complications of orthopedic implants. A two-year prospective study.

Authors:  R Kubba; J S Taylor; K E Marks
Journal:  Arch Dermatol       Date:  1981-09

9.  Neo-capsule tissue reactions in metal-on-metal hip arthroplasty.

Authors:  Wolf-Christoph Witzleb; Uwe Hanisch; Nicole Kolar; Frank Krummenauer; Klaus-Peter Guenther
Journal:  Acta Orthop       Date:  2007-04       Impact factor: 3.717

10.  Are allergic reactions to skin clips associated with delayed wound healing?

Authors:  C G Lhotka; T Szekeres; M Fritzer-Szekeres; G Schwarz; I Steffan; M Maschke; G Dubsky; M Kremser; K Zweymüller
Journal:  Am J Surg       Date:  1998-10       Impact factor: 2.565

View more
  7 in total

1.  [Allergic reactions as differential diagnosis for periprosthetic infection].

Authors:  H Meyer; A Krüger; A Roessner; C H Lohmann
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

2.  [Approach to painful hip resurfacing].

Authors:  L Gerdesmeyer; H Gollwitzer; P Diehl; M Fuerst; M Schmitt-Sody
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

Review 3.  [Hypersensitivity reactions to implantable cardiac pacemakers and defibrillators].

Authors:  B Kreft
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

4.  [Use of allergy implants in Germany: results of a survey].

Authors:  M Thomsen; M Rozak; P Thomas
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

Review 5.  Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology.

Authors:  Peter Thomas
Journal:  Allergo J Int       Date:  2014-09-29

6.  Increased risk of eczema after joint replacement: A population-based retrospective cohort study.

Authors:  Po-Yuan Wu; Chih-Hsin Muo; Chun-Hao Tsai
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

7.  Neuropathy Caused by Metal Hypersensitivity after Placement of Stainless Steel Plate.

Authors:  Sunyarn Niempoog; Seksan Kukreja
Journal:  Case Rep Orthop       Date:  2020-01-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.